Agilent B1500A/B1505A Programming Guide, Edition 11 4-29
Command Reference
Table 4-16 MFCMU Measurement Parameters
mode Primary Parameter Secondary Parameter
1 R (resistance, Ω) X (reactance, Ω)
2 G (conductance, S) B (susceptance, S)
10 Z (impedance, Ω) θ (phase, radian)
11 Z (impedance, Ω) θ (phase, degree)
20 Y (admittance, S) θ (phase, radian)
21 Y (admittance, S) θ (phase, degree)
100 Cp (parallel capacitance, F) G (conductance, S)
101 Cp (parallel capacitance, F) D (dissipation factor)
102 Cp (parallel capacitance, F) Q (quality factor)
103 Cp (parallel capacitance, F) Rp (parallel resistance, Ω)
200 Cs (series capacitance, F) Rs (series resistance, Ω)
201 Cs (series capacitance, F) D (dissipation factor)
202 Cs (series capacitance, F) Q (quality factor)
300 Lp (parallel inductance, H) G (conductance, S)
301 Lp (parallel inductance, H) D (dissipation factor)
302 Lp (parallel inductance, H) Q (quality factor)
303 Lp (parallel inductance, H) Rp (parallel resistance, Ω)
400 Ls (series inductance, H) Rs (series resistance, Ω)
401 Ls (series inductance, H) D (dissipation factor)
402 Ls (series inductance, H) Q (quality factor)