Agilent Technologies 8935 Series Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Multímetros Agilent Technologies 8935 Series. Agilent Technologies 8935 Series User`s manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 329
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - Programmer’s Guide

Agilent Technologies 8935 Series E6380A CDMA Cellular/PCS Base Station Test Set and E6381A TDMA Base Station Test SetProgrammer’s GuideFirmware Versio

Página 2

10 O:\Manuals\E6380A_Progguid\Book\Preface.fmNOTEHP-IB and GPIB are one and the same.Trademark AcknowledgementsHewlett-Packard and HP are register

Página 3 - Contents

100 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command Descriptions*SRE? (Service Request Enable Query) The Test Set

Página 4

Chapter 4 101IEEE Common CommandsCommon Command Descriptions*SAV (Save Instrument State) The *SAV command saves the present state of the Test Set into

Página 5

102 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command Descriptions

Página 6

1035 Triggering Measurements

Página 7

104 Chapter 5O:\Manuals\E6380A_Progguid\Book\Trigmeas.fmTriggering MeasurementsThis chapter gives you information about triggering your measurements.

Página 8

Chapter 5 105Triggering MeasurementsTriggering MeasurementsTriggering Measurements The measurement cycle is started (triggered) by the occurrence of a

Página 9

106 Chapter 5O:\Manuals\E6380A_Progguid\Book\Trigmeas.fmTriggering MeasurementsTriggering MeasurementsTrigger Modes The Trigger Mode is defined by two

Página 10 - Which Document is Required?

Chapter 5 107Triggering MeasurementsTriggering MeasurementsSettling Settling refers to the amount of delay introduced to allow signal transients to pr

Página 11 - Regulatory Information

108 Chapter 5O:\Manuals\E6380A_Progguid\Book\Trigmeas.fmTriggering MeasurementsTriggering MeasurementsDefault Trigger Mode The Trigger mode is set to

Página 12

Chapter 5 109Triggering MeasurementsTriggering MeasurementsTrigger Commands :TRIGger:IMMediate The :TRIGger:IMMediate command tells the Test Set to “s

Página 13 - Instrument

11Regulatory InformationManufacturer’s DeclarationThis statement is provided to comply with the requirements of the German Sound Emission Directive,

Página 14

110 Chapter 5O:\Manuals\E6380A_Progguid\Book\Trigmeas.fmTriggering MeasurementsTriggering MeasurementsExample 5-7 Settling Syntax:TRIGger:MODE:SETTli

Página 15

Chapter 5 111Triggering MeasurementsTriggering MeasurementsTrigger Mode Settings for Most Reliable Measurements Use the following Test Set configurati

Página 16 - ASSEMBLY (E6381A)

112 Chapter 5O:\Manuals\E6380A_Progguid\Book\Trigmeas.fmTriggering MeasurementsTriggering MeasurementsArming Hardware-Triggered Measurements Some meas

Página 17 - Commercial Products

1136 Advanced Operations

Página 18 - ASSISTANCE

114 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsIncreasing Measurement ThroughputIncreasing Measurement Throughput Measureme

Página 19 - Regional Sales Offices

Chapter 6 115Advanced OperationsIncreasing Measurement Throughput2. Autoranging The autoranging functions continuously calculate and adjust gain to pr

Página 20

116 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsIncreasing Measurement Throughput3. Frequency Counter Gate TimeThe frequency

Página 21 - Using HP-IB

Chapter 6 117Advanced OperationsIncreasing Measurement ThroughputOptimizing the Execution Speed of the Control Program Execution speed of the control

Página 22 - Overview of the Test Set

118 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsIncreasing Measurement ThroughputExample 6-7 Example #3OUTPUT 714;"ENC

Página 23 - Manual Control Mode

Chapter 6 119Advanced OperationsIncreasing Measurement ThroughputScreen Display Time Each time the screen being displayed on the Test Set (active scre

Página 24 - Using HP-IB

12 O:\Manuals\E6380A_Progguid\Book\Preface.fmSafetyGENERALThis product and related documentation must be reviewed for familiarization with safety ma

Página 25 - Chapter 1 25

120 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsIncreasing Measurement ThroughputExample 6-13 Syntax:SPECiaL:DISPlay?Exampl

Página 26 - 26 Chapter 1

Chapter 6 121Advanced OperationsStatus ReportingStatus Reporting This section describes the status reporting structure used in the Test Set. The struc

Página 27 - Chapter 1 27

122 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingFigure 6-1 Status Reporting Structure OverviewStatus Regist

Página 28 - 28 Chapter 1

Chapter 6 123Advanced OperationsStatus ReportingStatus Byte Register The Status Byte Register is an 8-bit register that is used to summarize the Summa

Página 29 - Chapter 1 29

124 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-1 details the Status Byte Register bit assignments a

Página 30 - Getting Started

Chapter 6 125Advanced OperationsStatus ReportingReading with a Serial Poll The contents of the Status Byte Register can be read by a serial poll from

Página 31 - Chapter 1 31

126 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingExample BASIC program to read Status Byte with *STB commandE

Página 32 - 32 Chapter 1

Chapter 6 127Advanced OperationsStatus ReportingStatus Register Structure Overview The structure of the register groups used in the Test Set is based

Página 33 - Chapter 1 33

128 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingStatus Register Model This section explains how the status r

Página 34 - 34 Chapter 1

Chapter 6 129Advanced OperationsStatus ReportingTransition Filters are read-write. Transition Filters are unaffected by a *CLS (clear status) command

Página 35

13Safety Considerations for this InstrumentWARNINGThis product is a Safety Class I instrument (provided with a protective earthing ground incorporat

Página 36 - Control Annunciators

130 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingStatus Reporting Structure Operation In general the status

Página 37 - Chapter 1 37

Chapter 6 131Advanced OperationsStatus ReportingFigure 6-4 Status Data Structure - Queue ModedataSummary Message Bit Queue Empty = "0&qu

Página 38 - Controller

132 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingStatus Register Group Contents Figure 6-5 shows the Status R

Página 39 - Basic Programming Examples

Chapter 6 133Advanced OperationsStatus ReportingOperation Status Register Group The Operation Status Register Group contains information about the sta

Página 40 - 40 Chapter 1

134 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-2 shows the Operation Status Register Group Conditio

Página 41

Chapter 6 135Advanced OperationsStatus ReportingAccessing the Operation Status Register Group’s Registers The following sections show the syntax and g

Página 42 - Remote Operation

136 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingExample 6-24 ExampleOUTPUT 714;"STAT:OPER:EVEN?"E

Página 43 - Remote Capabilities

Chapter 6 137Advanced OperationsStatus ReportingStandard Event Status Register Group The Standard Event Status Register Group is a specific implementa

Página 44 - Addressing

138 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-3 Standard Event Status Register Bit AssignmentsBit

Página 45 - Capabilities

Chapter 6 139Advanced OperationsStatus ReportingAccessing the Standard Event Status Register Group’s Registers The following sections show the syntax

Página 46

14 O:\Manuals\E6380A_Progguid\Book\Preface.fmWARNINGWhenever it is likely that the protection has been impaired, the instrument must be made inopera

Página 47

140 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingReading the Event Register Example 6-29 Syntax*ESR?Examp

Página 48 - Remote/Local Modes

Chapter 6 141Advanced OperationsStatus ReportingExample 6-34 ExampleOUTPUT 714;"*ESE?"ENTER 714;Register_valueThe *ESE? query allows the pr

Página 49 - Remote To Local Transitions

142 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingExample 6-38 ExampleOUTPUT 714;"*ESE 255"The *ESE

Página 50 - Clear Lockout/Set Local

Chapter 6 143Advanced OperationsStatus ReportingOutput Queue Group The Output Queue Group is a specific implementation of the status queue model descr

Página 51 - Measurement Results

144 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingAccessing the Output Queue When messages are sent to the Tes

Página 52 - Background

Chapter 6 145Advanced OperationsStatus ReportingError Message Queue Group The Error Message Queue Group is an implementation of the status queue model

Página 53 - Chapter 2 53

146 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingAccessing the Error Message Queue A message appears in the E

Página 54 - 54 Chapter 2

Chapter 6 147Advanced OperationsStatus ReportingQuestionable Data/Signal Register Group The Questionable Data/Signal Register Group contains informati

Página 55 - Example 2-2 Time-out Example

148 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-5 shows the Questionable Data/Signal Register Group’

Página 56 - Table 2-1

Chapter 6 149Advanced OperationsStatus ReportingAccessing the Questionable Data/Signal Register Group’s Registers The following sections show the synt

Página 57

15CAUTIONAlways use the three-prong ac power cord supplied with this product. Failure to ensure adequate earth grounding by not using this cord may

Página 58 - RMB ‘MAV’ Example Program

150 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingClearing the Event Register The EVENT register is cleared

Página 59 - Example 2-3 MAV Example

Chapter 6 151Advanced OperationsStatus ReportingCalibration Status Register Group The Calibration Status Register Group contains information about the

Página 60 - Example Program

152 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-6 details the Calibration Status Register Group’s Co

Página 61

Chapter 6 153Advanced OperationsStatus ReportingAccessing the Calibration Status Register Group’s Registers The following sections show the syntax and

Página 62

154 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingClearing the Event Register The EVENT register is cleared

Página 63 - HP-IB Command Guidelines

Chapter 6 155Advanced OperationsStatus ReportingHardware Status Register #2 Group The Hardware Status Register #2 Group contains information about the

Página 64 - 64 Chapter 3

156 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-7 shows the Hardware Status Register Group #2’s Cond

Página 65 - Guidelines for Operation

Chapter 6 157Advanced OperationsStatus ReportingAccessing the Hardware Status Register #2 Group’s Registers The following sections show the syntax and

Página 66

158 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingClearing the Event Register The EVENT register is cleared

Página 67

Chapter 6 159Advanced OperationsStatus ReportingHardware Status Register #1 Group The Hardware Status Register #1 Group contains information about the

Página 68

16 O:\Manuals\E6380A_Progguid\Book\Preface.fmWARNING - RUBIDIUM REFERENCE ASSEMBLY (E6381A)The optional Rubidium Reference assembly, A2A15, (OPTION

Página 69

160 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-8 shows the Hardware Status Register Group #1’s Cond

Página 70

Chapter 6 161Advanced OperationsStatus ReportingAccessing the Hardware Status Register #1 Group’s Registers The following sections show the syntax and

Página 71

162 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingExample 6-86 ExampleOUTPUT 714;"STAT:HARD1:PTR 256&quo

Página 72

Chapter 6 163Advanced OperationsStatus ReportingCommunicate Status Register Group The Communicate Status Register Group contains information about the

Página 73

164 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingTable 6-9 shows the Communicate Status Register Group’s Cond

Página 74 - 74 Chapter 3

Chapter 6 165Advanced OperationsStatus ReportingAccessing the Communicate Status Register Group’s Registers The following sections show the syntax and

Página 75

166 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsStatus ReportingClearing the Event Register The EVENT register is cleared

Página 76 - 76 Chapter 3

Chapter 6 167Advanced OperationsHP-IB Service RequestsHP-IB Service Requests The Test Set is capable of generating a “service request” when it require

Página 77

168 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsHP-IB Service RequestsSetting Up and Enabling SRQ Interrupts Test Set status

Página 78 - 78 Chapter 3

Chapter 6 169Advanced OperationsHP-IB Service RequestsService Request Enable Register Service request enabling allows the application programmer to se

Página 79 - Example 3-29 Example

17Agilent Technologies Warranty Statement for Commercial Products Product Name: E6380A/E6381ADuration of Warranty: 1 year1. Agilent Technologies war

Página 80 - 80 Chapter 3

170 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsHP-IB Service RequestsReading the Service Request Enable Register The Servic

Página 81 - Chapter 3 81

Chapter 6 171Advanced OperationsHP-IB Service RequestsWriting the Service Request Enable Register The Service Request Enable Register is written with

Página 82 - Using the STATe Command

172 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsHP-IB Service RequestsProcedure for Generating a Service Request The followi

Página 83 - ENTER 714;State_on_off

Chapter 6 173Advanced OperationsHP-IB Service RequestsExample BASIC Program to Set Up and Service an SRQ Interrupt The following Agilent Technologies

Página 84 - Sample HP-IB Program

174 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsHP-IB Service Requests470 !480 OUTPUT Inst_address;"STAT:CAL:PTR";

Página 85 - Chapter 3 85

Chapter 6 175Advanced OperationsHP-IB Service Requests1080 !1090 ENABLE INTR 7;21100 !1110 ! Start of the dummy loop:1120 !1130 LOOP1140 DISP "I

Página 86 - 86 Chapter 3

176 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsHP-IB Service Requests1700 ! appropriate action.1710 ! NOTE: Read the Event

Página 87

Chapter 6 177Advanced OperationsInstrument InitializationInstrument Initialization This section discusses the various methods available to the program

Página 88 - IEEE 488.2 Common Commands

178 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsInstrument InitializationMethods of Initialization There are six methods of

Página 89

Chapter 6 179Advanced OperationsInstrument InitializationPower-On Reset The Power-On Reset is accomplished by applying or cycling AC/DC power to the T

Página 90

18 O:\Manuals\E6380A_Progguid\Book\Preface.fm8. Agilent Technologies will be liable for damage to tangible property per incident up to the greater o

Página 91 - *RST (Reset)

180 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsInstrument InitializationThe Power-On Reset condition in the Test Set was sp

Página 92 - *TST? (Self-Test Query)

Chapter 6 181Advanced OperationsInstrument InitializationFront-panel PRESET Key The Front-panel Reset is accomplished by pressing the PRESET key on th

Página 93 - *OPC (Operation Complete)

182 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsInstrument Initialization*RST IEEE 488.2 Common Command The *RST Reset is ac

Página 94 - 180 SUBEND

Chapter 6 183Advanced OperationsInstrument InitializationThe *RST Reset condition in the Test Set was specifically designed to configure the instrumen

Página 95 - Example 4-6 Example

184 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsInstrument InitializationDevice Clear (DCL) HP-IB Bus Command The Device Cle

Página 96 - 96 Chapter 4

Chapter 6 185Advanced OperationsInstrument InitializationSelected Device Clear (SDC) HP-IB Bus Command The Selected Device Clear (SDC) Reset is accomp

Página 97 - Chapter 4 97

186 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsPassing ControlPassing Control Communications on the HP-IB bus are accomplis

Página 98 - *WAI (Wait To Complete)

Chapter 6 187Advanced OperationsPassing ControlConfiguring the Test Set as the System Controller To configure the Test Set as a System Controller, sel

Página 99 - *CLS (Clear Status)

188 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsPassing ControlPassing Control to the Test Set Control is passed to the Test

Página 100 - *PCB (Pass Control Back)

Chapter 6 189Advanced OperationsPassing ControlPassing Control Back to Another Controller The Test Set has two methods of passing control back to anot

Página 101 - *SAV (Save Instrument State)

19Regional Sales OfficesTable 2 Regional Sales and Service OfficesUnited States of America:Agilent TechnologiesTest and Measurement Call CenterP.O.

Página 102 - IEEE Common Commands

190 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsPassing ControlRequesting Control using IBASIC The Test Set has the capabili

Página 103 - Triggering Measurements

Chapter 6 191Advanced OperationsPassing ControlPass Control Examples The following examples illustrate how pass control could be implemented in two of

Página 104 - 104 Chapter 5

192 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsPassing ControlExample 6-110 Example PASS CONTROL 714This command p

Página 105

Chapter 6 193Advanced OperationsPassing ControlExample 6-111 Example10 COM /Hpib_names/ INTEGER Internal_hpib,Inst_address,Cntrl_state20 COM /Cn

Página 106 - Trigger Modes

194 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsPassing Control620 COM /Reg_vals/ INTEGER Status_byte,Stdevnt_reg_val630

Página 107 - Chapter 5 107

Chapter 6 195Advanced OperationsPassing Control380 GOTO Try_again390 ELSE400 PRINT "ERROR =";ERRN410 STOP420 END IF430

Página 108 - Default Trigger Mode

196 Chapter 6O:\Manuals\E6380A_Progguid\Book\Advoper.fmAdvanced OperationsPassing Control

Página 109 - Trigger Commands

1977 Memory Cards/Mass Storage

Página 110

198 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageThis chapter contains information about using the mass storage device

Página 111 - Measurement Pacing

Chapter 7 199Memory Cards/Mass StorageDefault File SystemDefault File System The Test Set’s default file system is DOS (the Microsoft Disk Operating

Página 112 - 112 Chapter 5

2 NoticeInformation contained in this document is subject to change without notice.All Rights Reserved. Reproduction, adaptation, or translation wit

Página 113 - Advanced Operations

20 O:\Manuals\E6380A_Progguid\Book\Preface.fm

Página 114 - Optimizing Measurement Speed

200 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageMass Storage Device OverviewMass Storage Device Overview There are fo

Página 115 - :AFAN:RANG ’HOLD’

Chapter 7 201Memory Cards/Mass StorageMass Storage Device OverviewFigure 7-1 Mass Storage DevicesPrograms and data can be retrieved from any of these

Página 116 - :RFAN:GTIM <value> MS

202 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageMass Storage Device Overview• Temporary Save/Recall register storageC

Página 117 - Program

Chapter 7 203Memory Cards/Mass StorageMass Storage Device Overview Typical Uses• Permanent storage of factory supplied utility programs • Permanent st

Página 118

204 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageMass Storage Device OverviewTypical Uses• Semi-permanent program and

Página 119

Chapter 7 205Memory Cards/Mass StorageMass Storage Device OverviewTypical Uses• Permanent storage of factory supplied application programs • Permanent

Página 120

206 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageDefault Mass Storage LocationsDefault Mass Storage Locations Built-in

Página 121 - Status Reporting

Chapter 7 207Memory Cards/Mass StorageDefault Mass Storage LocationsTests Subsystem The default mass storage location for the Tests Subsystem is set u

Página 122 - 122 Chapter 6

208 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageMass Storage AccessMass Storage Access Program and data files stored

Página 123 - Status Byte Register

Chapter 7 209Memory Cards/Mass StorageDOS File System ConsiderationsDOS File System Considerations The DOS file system is used on IBM compatible perso

Página 124

211 Using HP-IB

Página 125 - Chapter 6 125

210 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageDOS File System ConsiderationsPotential File Name Conflicts Unexpecte

Página 126 - 126 Chapter 6

Chapter 7 211Memory Cards/Mass StorageDOS File System ConsiderationsInitializing Media The INITIALIZE command is used to initialize a media (PC card,

Página 127 - Chapter 6 127

212 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageUsing the ROMUsing the ROM The Test Set comes with several Test Proce

Página 128 - 128 Chapter 6

Chapter 7 213Memory Cards/Mass StorageUsing PC CardsUsing PC Cards OTP (One-Time Programmable) cards provide removable read-only storage. File editing

Página 129 - Chapter 6 129

214 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageUsing PC CardsFigure 7-2 Inserting a Memory CardSetting the Write-Pr

Página 130 - 130 Chapter 6

Chapter 7 215Memory Cards/Mass StorageUsing PC CardsFigure 7-3 Inserting the Battery and Setting the Write-Protect SwitchBattery Holder BatteryCAUTIO

Página 131 - Chapter 6 131

216 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageUsing PC CardsThe Memory Card Battery SRAM PC cards use a lithium bat

Página 132 - 132 Chapter 6

Chapter 7 217Memory Cards/Mass StorageUsing PC CardsMemory Card Mass Storage Volume Specifier The front-panel PC card slot’s mass storage volume speci

Página 133 - Chapter 6 133

218 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageBacking Up Procedure and Library FilesBacking Up Procedure and Librar

Página 134 - Assignments

Chapter 7 219Memory Cards/Mass StorageCopying Files Using IBASIC CommandsCopying Files Using IBASIC Commands Files can be copied from one mass storage

Página 135

22 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBOverview of the Test SetOverview of the Test Set The Test Set combines numerous sepa

Página 136

220 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageCopying Files Using IBASIC CommandsExample 7-5 ExampleCOPY ":ME

Página 137 - Chapter 6 137

Chapter 7 221Memory Cards/Mass StorageUsing RAMUsing RAM RAM is a section of the Test Set’s internal RAM that has been set aside for use as a mass sto

Página 138

222 Chapter 7 O:\Manuals\E6380A_Progguid\Book\Mencard.fmMemory Cards/Mass StorageUsing RAMInitializing RAM Each RAM volume must be initialized before

Página 139

2238 IBASIC Controller

Página 140

224 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerIntroductionIntroduction The Test Set contains an instrument controller that ca

Página 141

Chapter 8 225IBASIC ControllerThe IBASIC Controller ScreenThe IBASIC Controller Screen The Test Set has a dedicated screen for interfacing with the bu

Página 142

226 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerThe IBASIC Controller ScreenExample 8-1 ExampleOUTPUT 714;"DISP TIBasic&q

Página 143 - Output Queue Group

Chapter 8 227IBASIC ControllerImportant Notes for Program DevelopmentImportant Notes for Program Development The Test Set is designed to operate the s

Página 144 - Enter 714;Output_data

228 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerProgram DevelopmentProgram Development There are three recommended approaches f

Página 145 - Error Message Queue Group

Chapter 8 229IBASIC ControllerProgram DevelopmentFigure 8-2 Program Development MethodsDevelop on Test Setusing screen"EDIT" modeRun progra

Página 146

Chapter 1 23Using HP-IBOverview of the Test SetManual Control Mode The Test Set’s primary instruments are shown on the left side of Figure 1-1 on page

Página 147 - Chapter 6 147

230 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerInterfacing to the IBASIC Controller using Serial PortsInterfacing to the IBASI

Página 148 - Bit Assignments

Chapter 8 231IBASIC ControllerInterfacing to the IBASIC Controller using Serial PortsFigure 8-3 Serial Port Pin AssignmentsSerial Port 9 Configuratio

Página 149

232 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerInterfacing to the IBASIC Controller using Serial Ports6. Another method which

Página 150

Chapter 8 233IBASIC ControllerInterfacing to the IBASIC Controller using Serial PortsReceive and Transmit Pacing When receiving characters into the IB

Página 151

234 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerInterfacing to the IBASIC Controller using Serial PortsPC Configuration To prep

Página 152

Chapter 8 235IBASIC ControllerInterfacing to the IBASIC Controller using Serial PortsSetting Up HyperTerminal on your PC (Windows Version 3.1) 1. St

Página 153

236 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerInterfacing to the IBASIC Controller using Serial Ports9. Edit the Communicatio

Página 154

Chapter 8 237IBASIC ControllerInterfacing to the IBASIC Controller using Serial Ports3. To select a different communications port, enter the following

Página 155

238 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerInterfacing to the IBASIC Controller using Serial PortsSetting Up HP AdvanceLin

Página 156

Chapter 8 239IBASIC ControllerInterfacing to the IBASIC Controller using Serial Ports5. Press REMOTE CONFIG (to set up the Serial port you selected ab

Página 157

24 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBOverview of the Test SetInternal Automatic Control Mode In Internal Automatic Contro

Página 158

240 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerInterfacing to the IBASIC Controller using Serial Ports8. Press DONE to return

Página 159

Chapter 8 241IBASIC ControllerChoosing Your Development MethodChoosing Your Development Method There are three fundamental methods for developing IBAS

Página 160

242 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerChoosing Your Development MethodMethod 1 Using a BASIC language computer (eithe

Página 161

Chapter 8 243IBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerMethod #1. Program Development on an External BASIC

Página 162

244 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerConfigurin

Página 163

Chapter 8 245IBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerHP BASIC for Windows PC Configuration for Windows N

Página 164 - Assignment

246 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerProgram De

Página 165

Chapter 8 247IBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerExample 8-5 Example20 ! Establishes IO path to sel

Página 166

248 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerAfter the

Página 167 - HP-IB Service Requests

Chapter 8 249IBASIC ControllerMethod #1. Program Development on an External BASIC Language ComputerExample 8-7 Example10 ! PROGRAM TO UPLOAD IBASI

Página 168

Chapter 1 25Using HP-IBOverview of the Test SetDifferences Between the Test Set’s IBASIC Controller and Other Single-Tasking ControllersThe IBASIC con

Página 169 - Chapter 6 169

250 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #2. Developing Programs on the Test Set Using the IBASIC EDIT ModeMethod

Página 170

Chapter 8 251IBASIC ControllerMethod #2. Developing Programs on the Test Set Using the IBASIC EDIT ModeTo Access the IBASIC Command Line Field1. Posit

Página 171

252 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #2. Developing Programs on the Test Set Using the IBASIC EDIT ModeEnteri

Página 172 - 172 Chapter 6

Chapter 8 253IBASIC ControllerMethod #2. Developing Programs on the Test Set Using the IBASIC EDIT ModeSetting Up Function Keys In HyperTerminal When

Página 173 - SRQ Interrupt

254 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #2. Developing Programs on the Test Set Using the IBASIC EDIT ModeSettin

Página 174 - 174 Chapter 6

Chapter 8 255IBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)Method #3. Developing Programs Using Word P

Página 175 - Chapter 6 175

256 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)Wr

Página 176 - 176 Chapter 6

Chapter 8 257IBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)Transferring Programs from the Word Process

Página 177 - Instrument Initialization

258 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)As

Página 178 - Methods of Initialization

Chapter 8 259IBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)Example 8-8 Example10 ! ASCII_DN20 ! Pro

Página 179 - Power-On Reset

26 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBOverview of the Test SetExternal Automatic Control Mode In External Automatic Contro

Página 180 - 180 Chapter 6

260 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)Se

Página 181 - Front-panel PRESET Key

Chapter 8 261IBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)Sending ASCII Text Files over RS-232 with P

Página 182 - Off Print Title field

262 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerMethod #3. Developing Programs Using Word Processor on a PC (Least Preferred)17

Página 183 - Chapter 6 183

Chapter 8 263IBASIC ControllerUploading Programs from the Test Set to a PCUploading Programs from the Test Set to a PC As an overview, the following s

Página 184 - 184 Chapter 6

264 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerSerial I/O from IBASIC ProgramsSerial I/O from IBASIC Programs There are two se

Página 185 - Chapter 6 185

Chapter 8 265IBASIC ControllerSerial I/O from IBASIC ProgramsExample IBASIC Program Using Serial Port 10 The following program illustrates I/O to both

Página 186 - Passing Control

266 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerSerial I/O from IBASIC ProgramsSerial Port 10 Information Serial Port 10 is som

Página 187 - Chapter 6 187

Chapter 8 267IBASIC ControllerPROGram SubsystemPROGram Subsystem IntroductionThe PROGram Subsystem provides a set of commands which allow an external

Página 188 - 188 Chapter 6

268 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemTest Set PROGram SubsystemThe Test Set was designed to store o

Página 189 - Chapter 6 189

Chapter 8 269IBASIC ControllerPROGram SubsystemUnsupported SCPI CommandsThe Test Set does not support the following SCPI commands.:CATalog?:SELected:D

Página 190 - 190 Chapter 6

Chapter 1 27Using HP-IBOverview of the Test SetWriting programs for the Test Set One of the design goals for automatic control of the Test Set was tha

Página 191 - Pass Control Examples

270 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemPROGram Subsystem Commands See the “:PROGram Subsystem in the

Página 192 - PASS CONTROL 714

Chapter 8 271IBASIC ControllerPROGram SubsystemExample 8-11 SyntaxPROGram[:SELected]:DEFine <program> The DEFine command is used to create and

Página 193 - Example 6-111 Example

272 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-13 Example BASIC program to download an IBASIC prog

Página 194 - Example 6-112 Example

Chapter 8 273IBASIC ControllerPROGram SubsystemExample 8-16 Example BASIC program to download an IBASIC program to Test Set10 OUTPUT 714;"PROG:D

Página 195 - Chapter 6 195

274 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-19 Example BASIC program to upload an IBASIC progra

Página 196 - 196 Chapter 6

Chapter 8 275IBASIC ControllerPROGram SubsystemExample 8-21 ExampleOUTPUT 714;"PROGram:SELected:DELete:ALL" orOUTPUT 714;"PROG:DEL:ALL

Página 197 - Memory Cards/Mass Storage

276 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-23 ExampleOUTPUT 714;"PROGram:SELected:EXECute

Página 198 - 198 Chapter 7

Chapter 8 277IBASIC ControllerPROGram SubsystemExample 8-26 Example setting the value of a one dimensional array [Array(5)] with 6 elementsOUTPUT 714

Página 199 - Default File System

278 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemFor simple variables the value is returned as a series of ASCI

Página 200 - Mass Storage Device Overview

Chapter 8 279IBASIC ControllerPROGram SubsystemExample 8-30 Example querying the value of a one dimensional array [Array(5)] with 6 elementsOUTPUT 71

Página 201 - Microprocessor

28 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBOverview of the Test SetFigure 1-1 Manual Control ModeDisplayKEY-PAD/ROTARY KNOB SC

Página 202

280 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram Subsystem:STATe RUN|PAUSe|STOP|CONTinue The STATe command is used to

Página 203

Chapter 8 281IBASIC ControllerPROGram SubsystemExample 8-34 SyntaxPROGram[:SELected]:STATe?Example 8-35 ExampleOUTPUT 714;"PROGram:SELected:STA

Página 204

282 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-36 SyntaxPROGram[:SELected]:STRing <varname>{

Página 205

Chapter 8 283IBASIC ControllerPROGram SubsystemIf an attempt is made to query the value of a string variable or array and no IBASIC program is in the

Página 206 - Save/Recall Registers

284 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-42 Example of querying the value of a string array

Página 207 - Tests Subsystem

Chapter 8 285IBASIC ControllerPROGram SubsystemExample 8-43 SyntaxPROGram[:SELected]:WAITExample 8-44 ExampleOUTPUT 714;"PROGram:SELected:WAIT&

Página 208 - Mass Storage Access

286 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-47 Example BASIC program without using the :WAIT? q

Página 209 - Chapter 7 209

Chapter 8 287IBASIC ControllerPROGram SubsystemUsing the EXECute Command The PROGram:EXECute command can be used to list, edit and control IBASIC prog

Página 210 - File Naming Recommendations

288 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemExample 8-52 ExampleOUTPUT 714;"PROG:EXEC ’30 PRINT &quo

Página 211 - Initializing Media

Chapter 8 289IBASIC ControllerPROGram SubsystemDownloading An IBASIC Program Into the Test Set The following procedure uses the PROGram Subsystem comm

Página 212 - Using the ROM

Chapter 1 29Using HP-IBOverview of the Test SetFigure 1-2 Internal Automatic Control ModeDisplayKEY-PAD/ROTARY KNOBSCREENCONTROLHARDWAREINSTRUMENT CO

Página 213 - Using PC Cards

290 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerPROGram SubsystemUploading a Program From the Test Set The following BASIC prog

Página 214 - 214 Chapter 7

Chapter 8 291IBASIC ControllerPROGram SubsystemSaving an IBASIC Program To A PC card The following procedure can be used to save an IBASIC program fro

Página 215 - Chapter 7 215

292 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerThe TESTS SubsystemThe TESTS Subsystem The Test Set makes available to the user

Página 216 - The Memory Card Battery

Chapter 8 293IBASIC ControllerThe TESTS SubsystemTESTS Subsystem File Descriptions Three types of files are used in the TESTS Subsystem to store diffe

Página 217

294 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerThe TESTS SubsystemFigure 8-6 TESTS Subsystem File RelationshipTESTS Subsystem

Página 218 - 218 Chapter 7

Chapter 8 295IBASIC ControllerThe TESTS SubsystemFigure 8-7 The SOFTWARE MENU ScreenTESTS Subsystem User-Interface Screens The TESTS Subsystem allows

Página 219 - Copying an Entire Volume

296 Chapter 8O:\Manuals\E6380A_Progguid\Book\Ibasic.fmIBASIC ControllerThe TESTS Subsystem•The External Devices screen identifies all connected HP-IB

Página 220 - 220 Chapter 7

2979 Error Messages

Página 221 - Using RAM

298 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesGeneral Information About Error MessagesGeneral Information About Error Message

Página 222 - Initializing RAM

Chapter 9 299Error MessagesGeneral Information About Error MessagesIBASIC Error Messages IBASIC Error Messages are associated with IBASIC operation. I

Página 223 - IBASIC Controller

Contents 31. Using HP-IBOverview of the Test Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 224 - Introduction

30 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBGetting StartedGetting Started What is HP-IB? The Hewlett-Packard Interface Bus (HP-

Página 225 - The IBASIC Controller Screen

300 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesGeneral Information About Error MessagesUsually, negative numbers preceding the

Página 226 - 226 Chapter 8

Chapter 9 301Error MessagesGeneral Information About Error MessagesThe Message Display During instrument operation, various messages may appear on the

Página 227 - Chapter 8 227

302 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesGeneral Information About Error MessagesText Only Error Messages Operation erro

Página 228 - Program Development

Chapter 9 303Error MessagesGeneral Information About Error Messages• Cal file checksum incorrect - initializing file.This error usually occurs after c

Página 229 - Method 3

304 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesHP-IB ErrorsHP-IB Errors Most HP-IB errors occur when the control program attem

Página 230 - Serial Ports

Chapter 9 305Error MessagesText Only HP-IB ErrorsText Only HP-IB Errors Un-numbered (text only) HP-IB error messages are generally self-explanatory. F

Página 231

306 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesText Only HP-IB ErrorsIn order to save the current Test Set state into a Save/R

Página 232 - 232 Chapter 8

Chapter 9 307Error MessagesNumbered HP-IB Error DescriptionsNumbered HP-IB Error Descriptions The following HP-IB errors can be generated under any of

Página 233 - Receive and Transmit Pacing

308 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-12 Error -104Data type errorThe pa

Página 234 - PC Configuration

Chapter 9 309Error MessagesNumbered HP-IB Error DescriptionsExample 9-20 Error -114 Header suffix out of rangeIndicates that a nonheader character ha

Página 235 - Chapter 8 235

Chapter 1 31Using HP-IBGetting StartedHP-IB Information Provided in This Manual What Is Explained • How to configure the Test Set for HP-IB operation

Página 236

310 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-28 Error -134Suffix too longThe suf

Página 237

Chapter 9 311Error MessagesNumbered HP-IB Error DescriptionsExample 9-36 Error -152Parity errorParity errorExample 9-37 Error -158String data not al

Página 238

312 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-44 Error -180Macro errorThis error

Página 239

Chapter 9 313Error MessagesNumbered HP-IB Error DescriptionsExample 9-52 Error -211Trigger ignoredIndicates that a GET, *TRG, or triggering signal wa

Página 240 - Terminal Configuration

314 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-59 Error -222Data out of rangeIndic

Página 241

Chapter 9 315Error MessagesNumbered HP-IB Error DescriptionsExample 9-67 Error -251Missing mass storageIndicates that a legal program command or que

Página 242 - Method 2

316 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-74 Error -258Media protectedIndicat

Página 243 - Connect to HP-IB connector

Chapter 9 317Error MessagesNumbered HP-IB Error DescriptionsExample 9-81 Error -274Macro parameter errorIndicates that the macro definition improper

Página 244 - 244 Chapter 8

318 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-88 Error -282Illegal program nameTh

Página 245 - Windows NT Operating System

Chapter 9 319Error MessagesNumbered HP-IB Error DescriptionsExample 9-97 Error -313Calibration memory lostIndicates that nonvolatile calibration dat

Página 246

32 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBGetting StartedGeneral HP-IB Programming Guidelines The following guidelines should

Página 247

320 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-104 Error -420Query UNTERMINATEDIndi

Página 248 - 248 Chapter 8

Chapter 9 321Error MessagesNumbered HP-IB Error DescriptionsExample 9-109 Error -608Initialization of Input Module Relay Count file failed.Indicates t

Página 249 - Example 8-7 Example

322 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-116 Error -1307Timeout occurred whil

Página 250 - 250 Chapter 8

Chapter 9 323Error MessagesNumbered HP-IB Error DescriptionsExample 9-121 Error -1312Data from RVC contains invalid bits in word [1,2,3].Indicates tha

Página 251 - Chapter 8 251

324 Chapter 9 O:\Manuals\E6380A_Progguid\Book\Errormsg.fmError MessagesNumbered HP-IB Error DescriptionsExample 9-125 Error -1316Incomplete data recei

Página 252 - 252 Chapter 8

IndexIndex 325Symbols*CLS, 99*ESE, 99*ESE?, 99*ESR?, 99*IDN?, 89*OPC, 93*OPC?, 96*OPT?, 90*PCB, 100, 188*RCL, 100*RST, 91, 182*SAV, 101*SRE, 99, 171*

Página 253

326 Index Indexupload IBASIC code from Test Set, 249upload IBASIC program from Test Set, 274variables and arrays, 276wait (*WAI), 98Extended Addressin

Página 254

IndexIndex 327L.LIB Files, 293, 209Library Files, 209, 293backing up, 218Local Lockout, 50Local Mode, 48Local to Remote Transition, 49Local/Remote Tr

Página 255 - (Least Preferred)

328 Index Indextriggering, immediate, 109triggering, repetitive/single, 109triggering, settling, 110upload IBASIC code from Test Set, 249upload IBASIC

Página 256 - 256 Chapter 8

IndexIndex 329using semicolon command separator, 117using semicolon to output multiple commands, 67using upper/lower case letters, 65System Controlle

Página 257 - Chapter 8 257

Chapter 1 33Using HP-IBGetting Started6. Send the MEASure query command to initiate a reading. This will place the measured value into the Test Set’s

Página 258 - 258 Chapter 8

34 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBGetting Started• Guideline #2.If the program stops or “hangs up” when trying to ENTE

Página 259 - Example 8-8 Example

Chapter 1 35Using HP-IBGetting Started• Guideline #3.The syntax diagrams in the HP-IB Syntax Reference Guide show where single quotes are needed and w

Página 260 - HyperTerminal

36 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBGetting StartedControl Annunciators The letters and symbols at the top right corner

Página 261 - Communications Software

Chapter 1 37Using HP-IBGetting StartedPreparing the Test Set For HP-IB Use 1. If other HP-IB devices are in the system, attach an HP-IB cable from the

Página 262 - 262 Chapter 8

38 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBGetting StartedUsing the HP-IB with the Test Set’s built-in IBASIC Controller The Te

Página 263 - Chapter 8 263

Chapter 1 39Using HP-IBGetting StartedBasic Programming Examples The following simple examples illustrate the basic approach to controlling the Test S

Página 264 - Serial Ports 9 and 10

4 Contents4. IEEE Common CommandsIEEE 488.2 Common Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 265 - Chapter 8 265

40 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBGetting StartedTo Read a Field’s Setting over HP-IB1. Use the DISPlay command to acc

Página 266 - Serial Port 10 Information

Chapter 1 41Using HP-IBGetting StartedTo Make a Simple Measurement The basic method for making a measurement is very similar to the method used to rea

Página 267 - PROGram Subsystem

42 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBRemote OperationRemote Operation The Test Set can be operated remotely through the H

Página 268 - Test Set PROGram Subsystem

Chapter 1 43Using HP-IBRemote OperationRemote Capabilities Conformance to the IEEE 488.1-1987 Standard For all IEEE 488.1 functions implemented, the T

Página 269 - Chapter 8 269

44 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBAddressingAddressing Factory Set Address The Test Set’s HP-IB address is set to deci

Página 270 - PROGram Subsystem Commands

Chapter 1 45Using HP-IBIEEE 488.1 Remote Interface Message CapabilitiesIEEE 488.1 Remote Interface Message Capabilities The remote interface message c

Página 271

46 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBIEEE 488.1 Remote Interface Message CapabilitiesClear Lockout/Set LocalYes The Test

Página 272

Chapter 1 47Using HP-IBIEEE 488.1 Remote Interface Message CapabilitiesTrigger Yes If in remote programming mode and addressed to listen, the Test Set

Página 273

48 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBRemote/Local ModesRemote/Local Modes Remote Mode In Remote mode all front-panel keys

Página 274 - PROGram[:SELected]:DELete:ALL

Chapter 1 49Using HP-IBRemote/Local ModesLocal To Remote Transitions The Test Set switches from Local to Remote mode upon receipt of the Remote messag

Página 275

Contents 5Calibration Status Register Group . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151Hardware Status

Página 276

50 Chapter 1 O:\Manuals\E6380A_Progguid\Book\Usehpib.fmUsing HP-IBRemote/Local ModesLocal Lockout The Local Lockout mode disables the front-panel LOCA

Página 277

512 Methods For Reading Measurement Results

Página 278

52 Chapter 2O:\Manuals\E6380A_Progguid\Book\Measrslt.fmMethods For Reading Measurement ResultsBackgroundBackgroundOne of the most common remote user i

Página 279

Chapter 2 53Methods For Reading Measurement ResultsBackgroundThe following programs demonstrate a recommended technique for querying and entering data

Página 280

54 Chapter 2O:\Manuals\E6380A_Progguid\Book\Measrslt.fmMethods For Reading Measurement ResultsRMB ‘ON TIMEOUT’ Example ProgramRMB ‘ON TIMEOUT’ Example

Página 281

Chapter 2 55Methods For Reading Measurement ResultsRMB ‘ON TIMEOUT’ Example ProgramExample 2-2 Time-out Example10 COM /Io_names/ INTEGER Inst_addr,B

Página 282

56 Chapter 2O:\Manuals\E6380A_Progguid\Book\Measrslt.fmMethods For Reading Measurement ResultsRMB ‘ON TIMEOUT’ Example ProgramComments for Recommended

Página 283

Chapter 2 57Methods For Reading Measurement ResultsRMB ‘ON TIMEOUT’ Example Program380 Set up a time-out for any I/O activity on the HP-IB while the c

Página 284 - 284 Chapter 8

58 Chapter 2O:\Manuals\E6380A_Progguid\Book\Measrslt.fmMethods For Reading Measurement ResultsRMB ‘MAV’ Example ProgramRMB ‘MAV’ Example ProgramThe fo

Página 285

Chapter 2 59Methods For Reading Measurement ResultsRMB ‘MAV’ Example ProgramExample 2-3 MAV Example10 COM /Io_names/ INTEGER Inst_addr,Bus_addr20 CL

Página 286

6 ContentsCopying Files Using IBASIC Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .219Copying an Entire Vo

Página 287 - Using the EXECute Command

60 Chapter 2O:\Manuals\E6380A_Progguid\Book\Measrslt.fmMethods For Reading Measurement ResultsRMB ‘MAV’ Example ProgramComments for Recommended Routin

Página 288

Chapter 2 61Methods For Reading Measurement ResultsRMB ‘MAV’ Example Program360 Perform a serial poll to read the Status Byte from the Test Set. A ser

Página 289

62 Chapter 2O:\Manuals\E6380A_Progguid\Book\Measrslt.fmMethods For Reading Measurement ResultsRMB ‘MAV’ Example Program490 The following lines of code

Página 290 - 290 Chapter 8

633 HP-IB Command Guidelines

Página 291

64 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesSequential and Overlapped CommandsSequential and Overlapped Commands IE

Página 292 - The TESTS Subsystem

Chapter 3 65HP-IB Command GuidelinesGuidelines for OperationGuidelines for Operation The following topics discuss rules and guidelines for controlling

Página 293 - Chapter 8 293

66 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationUsing Quotes for String Entries Quotation marks

Página 294 - TESTS Subsystem Screens

Chapter 3 67HP-IB Command GuidelinesGuidelines for OperationExample 3-4 ExampleDISP AFANAFAN:INP:GAIN ’40 dB’Using the Semicolon to Output Multiple C

Página 295 - Chapter 8 295

68 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationExample 3-6 ExampleRFAN:FREQ 850MHZ;:AFAN:INP

Página 296 - 296 Chapter 8

Chapter 3 69HP-IB Command GuidelinesGuidelines for OperationDisplay Units (DUNits)Display Units are the units-of-measure used by the Test Set to displ

Página 297 - Error Messages

Contents 7PROGram Subsystem Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270Using the EXECute Com

Página 298

70 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationExample 3-16 mV:MEAS:RFR:POW:DUN MV Example 3-

Página 299 - HP-IB Error Messages

Chapter 3 71HP-IB Command GuidelinesGuidelines for OperationExample 3-26 Example!Query Display Units setting for TX Power measurement.OUTPUT 714;&quo

Página 300 - Text Only Error Messages

72 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationHP-IB Units (UNITs) HP-IB Units are the units-o

Página 301 - The Message Display

Chapter 3 73HP-IB Command GuidelinesGuidelines for OperationChanging HP-IB Units Use the UNITs command to change the HP-IB Units setting for selected

Página 302

74 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationGuidelines for HP-IB Units • When setting the

Página 303 - Chapter 9 303

Chapter 3 75HP-IB Command GuidelinesGuidelines for OperationAttribute Units (AUNits)Attribute Units are the units-of-measure used by the Test Set when

Página 304 - HP-IB Errors

76 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationDefault Data Function Values The majority of m

Página 305 - Text Only HP-IB Errors

Chapter 3 77HP-IB Command GuidelinesGuidelines for OperationThe Data Functions are set to their default values whenever• the power is cycled on the Te

Página 306 - 306 Chapter 9

78 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationIf it is not possible to properly convert all t

Página 307

Chapter 3 79HP-IB Command GuidelinesGuidelines for OperationExample 3-29 Example!Reset the Test SetOUTPUT 714;"*RST"!Set HIgh LIMIT value t

Página 308

8 Contents

Página 309

80 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationReading-back Attribute Units Use the AUNits? c

Página 310

Chapter 3 81HP-IB Command GuidelinesGuidelines for OperationGuidelines for Attribute Units • When setting the value of measurement functions REFeren

Página 311

82 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationUsing the STATe Command The STATe command corre

Página 312

Chapter 3 83HP-IB Command GuidelinesGuidelines for OperationReading back the measurement, instrument function, or data function state Use the query fo

Página 313

84 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for OperationSample HP-IB Program The following program was

Página 314

Chapter 3 85HP-IB Command GuidelinesGuidelines for Operation300 !310 !Measure and plot oscilloscope trace to see the waveform shape.320 DIM Trace(0:41

Página 315

86 Chapter 3O:\Manuals\E6380A_Progguid\Book\Guidelin.fmHP-IB Command GuidelinesGuidelines for Operation

Página 316

874 IEEE Common CommandsThis chapter describes IEEE 488.2 common commands.

Página 317

88 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsIEEE 488.2 Common CommandsIEEE 488.2 Common Commands The IEEE 488.2 Standard d

Página 318

Chapter 4 89IEEE Common CommandsCommon Command DescriptionsCommon Command Descriptions *IDN? (Identification Query) The *IDN? query causes a device to

Página 319

9About this manual, its companions, and product regulatory information.What is discussed in this manualThis manual explains how to program the Test

Página 320

90 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command Descriptions*OPT? (Option Identification Query) The *OPT? comma

Página 321

Chapter 4 91IEEE Common CommandsCommon Command Descriptions*RST (Reset) The *RST command resets the Test Set. When the *RST command is received the ma

Página 322

92 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command Descriptions*TST? (Self-Test Query) The *TST? self-test query c

Página 323

Chapter 4 93IEEE Common CommandsCommon Command Descriptions*OPC (Operation Complete) The *OPC command allows for synchronization between the Test Set

Página 324 - 324 Chapter 9

94 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command DescriptionsExample BASIC program - Service Request Example 4-5

Página 325 - Index 325

Chapter 4 95IEEE Common CommandsCommon Command DescriptionsExample BASIC program - Polling the Standard Event Status Register Example 4-6 Example10 I

Página 326 - 326 Index

96 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command Descriptions*OPC? (Operation Complete Query) The *OPC? query al

Página 327 - Index 327

Chapter 4 97IEEE Common CommandsCommon Command DescriptionsExample 4-7 Example BASIC program10 INTEGER Output_que_val20 OUTPUT 714;"*SRE 0"

Página 328 - 328 Index

98 Chapter 4 O:\Manuals\E6380A_Progguid\Book\Ieee.fmIEEE Common CommandsCommon Command Descriptions*WAI (Wait To Complete) The *WAI command stops the

Página 329 - Index 329

Chapter 4 99IEEE Common CommandsCommon Command Descriptions*CLS (Clear Status) The *CLS command clears the contents (sets all bits to zero) of all Eve

Comentários a estes Manuais

Sem comentários