Command Reference
SCPI Command Compatibility
Chapter 4294
SCPI Command Compatibility
:SYSTem:IDN
Supported All
:SYSTem:IDN "<string>"
This command modifies the identification string that the *IDN? query returns. Sending
an empty string returns the query output to its factory shipped setting. The maximum
string length is 72 characters.
*RST N/A
Range N/A
Key Entry N/A
Remarks Modification of the *IDN? query output enables the PSG to identify
itself as another signal generator when it is used as a backwards
compatible replacement.
The display diagnostic information, shown by pressing the
Diagnostic Info softkey, is not affected by this command.