Agilent Technologies EXG Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Geradores de energia Agilent Technologies EXG. Agilent Technologies EXG User`s guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Signal Generators

Agilent TechnologiesAgilent X-Series Signal GeneratorsN5171B/72B/73B EXG N5181B/82B/83B MXG User’s Guide

Página 2

Contentsx Agilent X-Series Signal Generators User’s GuideChoosing the Logic Type and Port Configuration . . . . . . . . . . . . . . . . . . . . . . .

Página 3

86 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Dual Power Meter Display Using the Dual Power Meter DisplayThe dual

Página 4

Agilent X-Series Signal Generators User’s Guide 87 Optimizing PerformanceUsing the Dual Power Meter DisplayFigure 5-2 Dual Power Meter Display MenuSe

Página 5

88 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Dual Power Meter Display Figure 5-3 Configuring the Power Sensor Ch

Página 6

Agilent X-Series Signal Generators User’s Guide 89 Optimizing PerformanceUsing the Dual Power Meter DisplayExample: Dual Power Meter CalibrationIn th

Página 7

90 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Dual Power Meter Display A Running Calibration(s) bar is displayed

Página 8

Agilent X-Series Signal Generators User’s Guide 91 Optimizing PerformanceUsing the Dual Power Meter DisplayFigure 5-8 Channel A Power Sensor Displa

Página 9

92 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Dual Power Meter Display 13. On the signal generator: Press Channel

Página 10 - Contents

Agilent X-Series Signal Generators User’s Guide 93 Optimizing PerformanceUsing the Dual Power Meter Display17. Press DoneCalibration progress bar is

Página 11

94 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Power Meter Servo Using the Power Meter ServoThe Power Meter Servo

Página 12

Agilent X-Series Signal Generators User’s Guide 95 Optimizing PerformanceUsing the Power Meter ServoPower Meter Servo ConfigurationThe following proc

Página 13 - Documentation Overview

Contents Agilent X-Series Signal Generators User’s Guide xiRecalling a User- Defined Burst Shape Curve . . . . . . . . . . . . . . . . . . . . . . .

Página 14

96 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Power Meter Servo Power Meter Continuous performs the adjustment a

Página 15 - 1 Signal Generator Overview

Agilent X-Series Signal Generators User’s Guide 97 Optimizing PerformanceUsing Flatness CorrectionUsing Flatness CorrectionUser flatness correction a

Página 16 - Signal Generator Features

98 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Flatness Correction Figure 5-16 User Flatness Correction SoftkeysConfir

Página 17 - Signal Generator Overview

Agilent X-Series Signal Generators User’s Guide 99 Optimizing PerformanceUsing Flatness CorrectionCreating a User Flatness Correction ArrayIn this ex

Página 18 - Modes of Operation

100 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Flatness Correction Connect the Equipment•Agilent N1911A/12A or E4419A

Página 19 - Front Panel Overview

Agilent X-Series Signal Generators User’s Guide 101 Optimizing PerformanceUsing Flatness CorrectionFigure 5-17 Configure Power Meter Menu SoftkeysBas

Página 20 - 7. MENUS

102 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Flatness Correction Configure the U2000A/01A/02A/04A Power Sensor1. Co

Página 21

Agilent X-Series Signal Generators User’s Guide 103 Optimizing PerformanceUsing Flatness Correctionelse If Sockets LAN or VXI–11 LAN: Press Power Me

Página 22

104 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Flatness Correction 2. Connect the power meter to the RF output and en

Página 23 - 22. Power Switch and LEDs

Agilent X-Series Signal Generators User’s Guide 105 Optimizing PerformanceUsing Flatness CorrectionRecalling and Applying a User Flatness Correction

Página 24 - Front Panel Display

Contentsxii Agilent X-Series Signal Generators User’s GuideUsing Secure Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 25 - 4. Amplitude Area

106 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Internal Channel Correction (N5172B/82B Only) Using Internal Channel C

Página 26 - 7. Softkey Label Area

Agilent X-Series Signal Generators User’s Guide 107 Optimizing PerformanceUsing Internal Channel Correction (N5172B/82B Only)• If active, the ACP Int

Página 27 - 1. AC Power Receptacle

108 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Internal Channel Correction (N5172B/82B Only) Figure 5-18 Internal Cha

Página 28 - 5 V to +5 V, nominal

Agilent X-Series Signal Generators User’s Guide 109 Optimizing PerformanceUsing Internal Channel Correction (N5172B/82B Only)Configure Internal Chann

Página 29

110 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using External Leveling (N5173B/83B Only) Using External Leveling (N5173B/83

Página 30 - typically <10 mV

Agilent X-Series Signal Generators User’s Guide 111 Optimizing PerformanceUsing External Leveling (N5173B/83B Only)External leveling lets you move th

Página 31 - DIGITAL BUS I/O

112 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using External Leveling (N5173B/83B Only) that the Ext Leveling Amptd Offset

Página 32 - AUX I/O Connector

Agilent X-Series Signal Generators User’s Guide 113 Optimizing PerformanceUsing External Leveling (N5173B/83B Only)Figure 5-20 Typical Diode Detector

Página 33

114 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using External Leveling (N5173B/83B Only) feedback for the detection circuit

Página 34

Agilent X-Series Signal Generators User’s Guide 115 Optimizing PerformanceUsing External Leveling (N5173B/83B Only)Recommended Equipment• Agilent 847

Página 35

Agilent X-Series Signal Generators User’s Guide xiiiDocumentation OverviewGetting Started Guide• Safety Information• Receiving the Instrument• Environ

Página 36

116 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using External Leveling (N5173B/83B Only) With external leveling and Option

Página 37

Agilent X-Series Signal Generators User’s Guide 117 Optimizing PerformanceUsing External Leveling (N5173B/83B Only)Adjusting the Signal Generator Dis

Página 38

118 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Unleveled Operating Modes Using Unleveled Operating ModesFigure 5-22 P

Página 39

Agilent X-Series Signal Generators User’s Guide 119 Optimizing PerformanceUsing Unleveled Operating ModesALC Off ModeTurning ALC off deactivates the

Página 40 - 15. Z AXIS OUTPUT

120 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using Unleveled Operating Modes • Fixed – Reference level is 0.5 Vrms. This

Página 41

Agilent X-Series Signal Generators User’s Guide 121 Optimizing PerformanceUsing Unleveled Operating ModesThe FIXED, RMS, and MANUAL references use a

Página 42 - User Preferences

122 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using an Output Offset, Reference, or Multiplier Using an Output Offset, Ref

Página 43 - Power On and Preset

Agilent X-Series Signal Generators User’s Guide 123 Optimizing PerformanceUsing an Output Offset, Reference, or MultiplierSetting an Output Reference

Página 44 - Setting Time and Date

124 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using an Output Offset, Reference, or Multiplier To set a new frequency or a

Página 45 - Upgrading Firmware

Agilent X-Series Signal Generators User’s Guide 125 Optimizing PerformanceUsing an Output Offset, Reference, or MultiplierWhen using the signal gener

Página 46 - Remote Operation Preferences

xiv Agilent X-Series Signal Generators User’s GuideSCPI Reference• SCPI Basics• Basic Function Commands• LXI System Commands• System Commands• Analog

Página 47 - page 34

126 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using the Frequency and Phase Reference Softkeys Using the Frequency and Pha

Página 48

Agilent X-Series Signal Generators User’s Guide 127 Optimizing PerformanceUsing Free Run, Step Dwell, and Timer Triggerdepending on options) plus the

Página 49 - Figure 2-1 N5171B/72B/81B/82B

128 Agilent X-Series Signal Generators User’s GuideOptimizing Performance Using a USB Keyboard Using a USB KeyboardYou can use a USB keyboard to remot

Página 50 - Figure 2-2 N5173B/83B

Agilent X-Series Signal Generators User’s Guide 1296 Using Pulse Modulation (Option UNW or 320)Before using this information, you should be familiar

Página 51 - Figure 2-3 N5171B/72B/81B/82B

130 Agilent X-Series Signal Generators User’s GuideUsing Pulse Modulation (Option UNW or 320) Figure 6-1 Pulse Softkeyspage 133page 133Latency from t

Página 52 - Figure 2-4 N5173B/83B

Agilent X-Series Signal Generators User’s Guide 131 Using Pulse Modulation (Option UNW or 320)Pulse CharacteristicsPulse CharacteristicsNOTE When usi

Página 53 - Enabling an Option

132 Agilent X-Series Signal Generators User’s GuideUsing Pulse Modulation (Option UNW or 320) Pulse Characteristics Figure 6-2 Adjustable DoubletFigu

Página 54 - Viewing Options and Licenses

Agilent X-Series Signal Generators User’s Guide 133 Using Pulse Modulation (Option UNW or 320)The Basic ProcedureThe Basic Procedure1. Preset the sig

Página 55

134 Agilent X-Series Signal Generators User’s GuideUsing Pulse Modulation (Option UNW or 320) Example 4. Set the pulse period to 100 microseconds: Pre

Página 56

Agilent X-Series Signal Generators User’s Guide 135 Using Pulse Modulation (Option UNW or 320)Pulse Train (Option 320 – Requires: Option UNW)Pulse Tr

Página 57 - 3 Basic Operation

Agilent X-Series Signal Generators User’s Guide 11 Signal Generator OverviewCAUTION To avoid damaging or degrading the performance of the instrument,

Página 58 - Viewing Key Descriptions

136 Agilent X-Series Signal Generators User’s GuideUsing Pulse Modulation (Option UNW or 320) Pulse Train (Option 320 – Requires: Option UNW) Figure 6

Página 59 - Entering Alpha Characters

Agilent X-Series Signal Generators User’s Guide 137 Using Pulse Modulation (Option UNW or 320)Pulse Train (Option 320 – Requires: Option UNW)Figure 6

Página 60 - (vector models only)

138 Agilent X-Series Signal Generators User’s GuideUsing Pulse Modulation (Option UNW or 320) Pulse Train (Option 320 – Requires: Option UNW) Figure 6

Página 61 - Basic Operation

Agilent X-Series Signal Generators User’s Guide 139 Using Pulse Modulation (Option UNW or 320)Pulse Train (Option 320 – Requires: Option UNW)Figure 6

Página 62 - Basic Operation

140 Agilent X-Series Signal Generators User’s GuideUsing Pulse Modulation (Option UNW or 320) Pulse Train (Option 320 – Requires: Option UNW)

Página 63 - Setting ALC Bandwidth Control

Agilent X-Series Signal Generators User’s Guide 1417 Basic Digital Operation—No BBG Option InstalledBefore using this information, you should be fam

Página 64 - Configuring a Swept Output

142 Agilent X-Series Signal Generators User’s GuideBasic Digital Operation—No BBG Option InstalledI/Q ModulationI/Q ModulationThe following factors co

Página 65 - Figure 3-4 Sweep Softkeys

Agilent X-Series Signal Generators User’s Guide 143Basic Digital Operation—No BBG Option InstalledI/Q ModulationThe following table shows common uses

Página 66 - Step Sweep

144 Agilent X-Series Signal Generators User’s GuideBasic Digital Operation—No BBG Option InstalledI/Q Modulation

Página 67

Agilent X-Series Signal Generators User’s Guide 1458 Basic Digital Operation (Option 653/655/656/657)Before using this information, you should be f

Página 68

2 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewSignal Generator FeaturesSignal Generator Features• N5171B/N5181B, RF analog

Página 69 - List Sweep

146 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform File Basics Waveform File BasicsThere ar

Página 70 - Waveforms are available

Agilent X-Series Signal Generators User’s Guide 147 Basic Digital Operation (Option 653/655/656/657)Waveform File BasicsFigure 8-1 Dual ARB Softkeys

Página 71 - −2.5 > dBm

148 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Storing, Loading, and Playing a Waveform Segment

Página 72 - Example: Using a Single Sweep

Agilent X-Series Signal Generators User’s Guide 149 Basic Digital Operation (Option 653/655/656/657)Storing, Loading, and Playing a Waveform Segment

Página 73 - Modulating the Carrier Signal

150 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Storing, Loading, and Playing a Waveform Segment

Página 74 - AM modulation format on

Agilent X-Series Signal Generators User’s Guide 151 Basic Digital Operation (Option 653/655/656/657)Waveform SequencesWaveform SequencesFigure 8-3 W

Página 75 - Working with Files

152 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform Sequences Creating a SequenceA waveform

Página 76 - File Softkeys

Agilent X-Series Signal Generators User’s Guide 153 Basic Digital Operation (Option 653/655/656/657)Waveform Sequences3. Name and store the waveform

Página 77

154 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform Sequences 2. Change the first segment so

Página 78

Agilent X-Series Signal Generators User’s Guide 155 Basic Digital Operation (Option 653/655/656/657)Saving a Waveform’s Settings & Parameters2.

Página 79 - Storing a File

Agilent X-Series Signal Generators User’s Guide 3 Signal Generator OverviewSignal Generator Features• flexible reference input, 1 – 50 MHz (Option 1ER

Página 80

156 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Saving a Waveform’s Settings & Parameters Tab

Página 81

Agilent X-Series Signal Generators User’s Guide 157 Basic Digital Operation (Option 653/655/656/657)Saving a Waveform’s Settings & ParametersVie

Página 82

158 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Saving a Waveform’s Settings & Parameters The

Página 83

Agilent X-Series Signal Generators User’s Guide 159 Basic Digital Operation (Option 653/655/656/657)Saving a Waveform’s Settings & Parametersd.

Página 84

160 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Saving a Waveform’s Settings & Parameters 2.

Página 85 - Sequence Register

Agilent X-Series Signal Generators User’s Guide 161 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersUsing Waveform MarkersThe

Página 86

162 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Waveform Marker ConceptsTh

Página 87 - Reading Error Messages

Agilent X-Series Signal Generators User’s Guide 163 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersALC Hold Marker FunctionWh

Página 88

164 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Close–up of averagingThe A

Página 89

Agilent X-Series Signal Generators User’s Guide 165 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersSample range begins on fir

Página 90 - Analog Modulation Sources

4 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewModes of OperationModes of OperationDepending on the model and installed opt

Página 91

166 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Accessing Marker Utilities

Página 92 - AM Depth > value

Agilent X-Series Signal Generators User’s Guide 167 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersViewing Waveform Segment M

Página 93 - Currently selected

168 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Press Last Mkr Point >

Página 94 - Setting the Wideband AM

Agilent X-Series Signal Generators User’s Guide 169 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersPlacing a Marker on a Sing

Página 95 - LF Out Modulation Sources

170 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers This causes the marker to

Página 96

Agilent X-Series Signal Generators User’s Guide 171 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersViewing a Marker PulseWhen

Página 97 - LF Out annunciator

172 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Using the RF Blanking Mark

Página 98

Agilent X-Series Signal Generators User’s Guide 173 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersMarker Polarity = Positive

Página 99 - 5 Optimizing Performance

174 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Setting Marker PolaritySet

Página 100 - Figure 5- 2, and Figure 5- 3

Agilent X-Series Signal Generators User’s Guide 175 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersFigure 8-6 Waveform Sequen

Página 101 - Optimizing Performance

Agilent X-Series Signal Generators User’s Guide 5 Signal Generator OverviewFront Panel Overview• Two–tone mode produces two separate continuous wave s

Página 102 - Optimizing Performance

176 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Waveform Markers Enabling and Disabling Mar

Página 103

Agilent X-Series Signal Generators User’s Guide 177 Basic Digital Operation (Option 653/655/656/657)Using Waveform MarkersUsing the EVENT Output Sig

Página 104

178 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Triggering a Waveform Triggering a WaveformFigure

Página 105

Agilent X-Series Signal Generators User’s Guide 179 Basic Digital Operation (Option 653/655/656/657)Triggering a WaveformTrigger TypeType defines th

Página 106

180 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Triggering a Waveform • Segment Advance mode play

Página 107

Agilent X-Series Signal Generators User’s Guide 181 Basic Digital Operation (Option 653/655/656/657)Triggering a WaveformExample: Segment Advance Tr

Página 108 - Using the Power Meter Servo

182 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Triggering a Waveform Example: Gated TriggeringGa

Página 109 - For details on each key, use

Agilent X-Series Signal Generators User’s Guide 183 Basic Digital Operation (Option 653/655/656/657)Triggering a Waveform7. On the function generato

Página 110 - protects the

184 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Triggering a Waveform Example: External Triggerin

Página 111 - Using Flatness Correction

Agilent X-Series Signal Generators User’s Guide 185 Basic Digital Operation (Option 653/655/656/657)Clipping a WaveformClipping a WaveformDigitally

Página 112

Users GuideNotices© Agilent Technologies, Inc. 2014No part of this manual may be reproduced in any form or by any means (including elec-tronic storage

Página 113

6 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewFront Panel Overviewindicators, frequency and amplitude settings, and error

Página 114 - Connect the Equipment

186 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Clipping a Waveform How Power Peaks DevelopTo see

Página 115

Agilent X-Series Signal Generators User’s Guide 187 Basic Digital Operation (Option 653/655/656/657)Clipping a WaveformCombining the I and Q Wavefor

Página 116

188 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Clipping a Waveform How Peaks Cause Spectral Regr

Página 117

Agilent X-Series Signal Generators User’s Guide 189 Basic Digital Operation (Option 653/655/656/657)Clipping a WaveformHow Clipping Reduces Peak–to–

Página 118

190 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Clipping a Waveform Figure 8-10 Rectangular Clipp

Página 119

Agilent X-Series Signal Generators User’s Guide 191 Basic Digital Operation (Option 653/655/656/657)Clipping a WaveformFigure 8-11 Reduction of Peak

Página 120

192 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Clipping a Waveform Configuring Circular Clipping

Página 121

Agilent X-Series Signal Generators User’s Guide 193 Basic Digital Operation (Option 653/655/656/657)Clipping a WaveformConfiguring Rectangular Clipp

Página 122

194 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Scaling a Waveform Scaling a WaveformThe signal g

Página 123

Agilent X-Series Signal Generators User’s Guide 195 Basic Digital Operation (Option 653/655/656/657)Scaling a WaveformHow DAC Over–Range Errors Occu

Página 124

Agilent X-Series Signal Generators User’s Guide 7 Signal Generator OverviewFront Panel Overview8. TriggerWhen trigger mode is set to Trigger Key, this

Página 125

196 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Scaling a Waveform How Scaling Eliminates DAC Ove

Página 126 - Measured output power

Agilent X-Series Signal Generators User’s Guide 197 Basic Digital Operation (Option 653/655/656/657)Scaling a WaveformSetting Waveform Runtime Scali

Página 127

198 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Scaling a Waveform Setting Waveform ScalingWavefo

Página 128 - Configure External Leveling

Agilent X-Series Signal Generators User’s Guide 199 Basic Digital Operation (Option 653/655/656/657)Scaling a WaveformApply Scaling to the Copied Wa

Página 129

200 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Setting the Baseband Frequency Offset Setting the

Página 130

Agilent X-Series Signal Generators User’s Guide 201 Basic Digital Operation (Option 653/655/656/657)Setting the Baseband Frequency OffsetNOTE Changi

Página 131

202 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Setting the Baseband Frequency Offset DAC Over–Ra

Página 132

Agilent X-Series Signal Generators User’s Guide 203 Basic Digital Operation (Option 653/655/656/657)Setting the Baseband Frequency OffsetFigure 8-14

Página 133 - Power Search Mode

204 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) I/Q Modulation I/Q ModulationThe following factor

Página 134

Agilent X-Series Signal Generators User’s Guide 205 Basic Digital Operation (Option 653/655/656/657)I/Q ModulationFigure 8-15 I/Q Display and Softke

Página 135

8 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewFront Panel OverviewNOTE The Mod On/Off hardkey and LED functionality are on

Página 136 - Setting an Output Offset

206 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) I/Q Modulation Using the Rear Panel I and Q Outpu

Página 137 - Setting an Output Reference

Agilent X-Series Signal Generators User’s Guide 207 Basic Digital Operation (Option 653/655/656/657)I/Q ModulationConfiguring the Front Panel Inputs

Página 138 - Reference, or Multiplier

208 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) I/Q Adjustments I/Q AdjustmentsUse the I/Q Adjust

Página 139 - 3 GHz so that the

Agilent X-Series Signal Generators User’s Guide 209 Basic Digital Operation (Option 653/655/656/657)I/Q AdjustmentsThe I/Q adjustment, I/Q Delay, is

Página 140

210 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) I/Q Calibration I/Q CalibrationUse the I/Q calibr

Página 141 - N5173B/83B only

Agilent X-Series Signal Generators User’s Guide 211 Basic Digital Operation (Option 653/655/656/657)I/Q CalibrationI/Q > I/Q CalibrationAvailable

Página 142 - Using a USB Keyboard

212 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using the Equalization Filter Using the Equalizat

Página 143

Agilent X-Series Signal Generators User’s Guide 213 Basic Digital Operation (Option 653/655/656/657)Using the Equalization FilterFigure 8-16 Int Equ

Página 144 - Figure 6-1 Pulse Softkeys

214 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Finite Impulse Response (FIR) Filters in th

Página 145 - Pulse Characteristics

Agilent X-Series Signal Generators User’s Guide 215 Basic Digital Operation (Option 653/655/656/657)Using Finite Impulse Response (FIR) Filters in t

Página 146

Agilent X-Series Signal Generators User’s Guide 9 Signal Generator OverviewFront Panel Overviewmessage displays below the labels. To display the next

Página 147 - The Basic Procedure

216 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Finite Impulse Response (FIR) Filters in th

Página 148 - Example

Agilent X-Series Signal Generators User’s Guide 217 Basic Digital Operation (Option 653/655/656/657)Using Finite Impulse Response (FIR) Filters in t

Página 149 - SCPI Commands:

218 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Using Finite Impulse Response (FIR) Filters in th

Página 150

Agilent X-Series Signal Generators User’s Guide 219 Basic Digital Operation (Option 653/655/656/657)Using Finite Impulse Response (FIR) Filters in t

Página 151 - 5th, 6th, and 7th

220 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Modifying a FIR Filter Using the FIR Table Editor

Página 152

Agilent X-Series Signal Generators User’s Guide 221 Basic Digital Operation (Option 653/655/656/657)Modifying a FIR Filter Using the FIR Table Edito

Página 153

222 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Modifying a FIR Filter Using the FIR Table Editor

Página 154

Agilent X-Series Signal Generators User’s Guide 223 Basic Digital Operation (Option 653/655/656/657)Modifying a FIR Filter Using the FIR Table Edito

Página 155

224 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Setting the Real-Time Modulation Filter Setting t

Página 156 - I/Q Modulation

Agilent X-Series Signal Generators User’s Guide 225 Basic Digital Operation (Option 653/655/656/657)Multiple Baseband Generator SynchronizationCommo

Página 157

10 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewFront Panel DisplayFront Panel Display1. Active Function AreaThis area disp

Página 158

226 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Multiple Baseband Generator Synchronization Figur

Página 159

Agilent X-Series Signal Generators User’s Guide 227 Basic Digital Operation (Option 653/655/656/657)Multiple Baseband Generator SynchronizationFigur

Página 160 - Waveform File Basics

228 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Multiple Baseband Generator Synchronization Under

Página 161 - Figure 8-1 Dual ARB Softkeys

Agilent X-Series Signal Generators User’s Guide 229 Basic Digital Operation (Option 653/655/656/657)Multiple Baseband Generator Synchronizationgener

Página 162

230 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Multiple Baseband Generator Synchronization 4. Ex

Página 163 - Playing a Waveform Segment

Agilent X-Series Signal Generators User’s Guide 231 Basic Digital Operation (Option 653/655/656/657)Multiple Baseband Generator Synchronization1. On

Página 164 - 5. Configure the RF Output:

232 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Understanding Option 012 (LO In/Out for Phase Coh

Página 165 - Waveform Sequences

Agilent X-Series Signal Generators User’s Guide 233 Basic Digital Operation (Option 653/655/656/657)Understanding Option 012 (LO In/Out for Phase Co

Página 166 - Creating a Sequence

234 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Understanding Option 012 (LO In/Out for Phase Coh

Página 167 - Editing a Sequence

Agilent X-Series Signal Generators User’s Guide 235 Basic Digital Operation (Option 653/655/656/657)Understanding Option 012 (LO In/Out for Phase Co

Página 168 - Playing a Sequence

Agilent X-Series Signal Generators User’s Guide 11 Signal Generator OverviewFront Panel Display4. Amplitude AreaThis area displays the current output

Página 169 - For details on each key

236 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Real-Time Applications Real-Time ApplicationsThe

Página 170

Agilent X-Series Signal Generators User’s Guide 237 Basic Digital Operation (Option 653/655/656/657)Waveform LicensingWaveform Licensing Waveform li

Página 171

238 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform Licensing Waveform Licensing Softkeys Ov

Página 172

Agilent X-Series Signal Generators User’s Guide 239 Basic Digital Operation (Option 653/655/656/657)Waveform LicensingFigure 8-34 Waveform Licensing

Página 173 - Values differ between

240 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform Licensing Figure 8-35 Waveform Licensing

Página 174

Agilent X-Series Signal Generators User’s Guide 241 Basic Digital Operation (Option 653/655/656/657)Waveform LicensingTable 8-6 Waveform Licensing S

Página 175 - Using Waveform Markers

242 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform Licensing Example: Licensing a Signal St

Página 176 - Waveform Marker Concepts

Agilent X-Series Signal Generators User’s Guide 243 Basic Digital Operation (Option 653/655/656/657)Waveform Licensing4. License the waveform:a. Pre

Página 177

244 Agilent X-Series Signal Generators User’s Guide Basic Digital Operation (Option 653/655/656/657) Waveform Licensing Waveform Licensing Warning Mes

Página 178

Agilent X-Series Signal Generators User’s Guide 2459 Adding Real–Time Noise to a Signal (Option 403)Before using this information, you should be fam

Página 179

12 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewFront Panel Display5. Error Message AreaThis area displays abbreviated erro

Página 180 - Accessing Marker Utilities

246 Agilent X-Series Signal Generators User’s GuideAdding Real–Time Noise to a Signal (Option 403) Adding Real–Time Noise to a Dual ARB Waveform Figur

Página 181

Agilent X-Series Signal Generators User’s Guide 247 Adding Real–Time Noise to a Signal (Option 403)Adding Real–Time Noise to a Dual ARB WaveformFigur

Página 182

248 Agilent X-Series Signal Generators User’s GuideAdding Real–Time Noise to a Signal (Option 403) Adding Real–Time Noise to a Dual ARB Waveform Figur

Página 183

Agilent X-Series Signal Generators User’s Guide 249 Adding Real–Time Noise to a Signal (Option 403)Adding Real–Time Noise to a Dual ARB WaveformFigur

Página 184

250 Agilent X-Series Signal Generators User’s GuideAdding Real–Time Noise to a Signal (Option 403) Adding Real–Time Noise to a Dual ARB Waveform Figur

Página 185 - Marker points on

Agilent X-Series Signal Generators User’s Guide 251 Adding Real–Time Noise to a Signal (Option 403)Using Real Time I/Q Baseband AWGNUsing Real Time I

Página 186

252 Agilent X-Series Signal Generators User’s GuideAdding Real–Time Noise to a Signal (Option 403) Using Real Time I/Q Baseband AWGN

Página 187

25310 Digital Signal Interface Module (Option 003/004)This chapter provides information on the N5102A Baseband Studio Digital Signal Interface Module.

Página 188 - Setting Marker Polarity

254 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Clock Timing Figure 10-1 Data Setup Menu for a Pa

Página 189

Agilent X-Series Signal Generators User’s Guide 255 Digital Signal Interface Module (Option 003/004)Clock TimingThe levels will degrade above the wa

Página 190 - 3 and 4 are enabled for this

Agilent X-Series Signal Generators User’s Guide 13 Signal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)Rear Panel Overv

Página 191

256 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Clock Timing sample rate is reduced by the clocks

Página 192 - Triggering a Waveform

Agilent X-Series Signal Generators User’s Guide 257 Digital Signal Interface Module (Option 003/004)Clock TimingFigure 10-2 Clock Source SelectionWh

Página 193 - Trigger Type

258 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Clock Timing Signal Generator Frequency Reference

Página 194 - Trigger Source

Agilent X-Series Signal Generators User’s Guide 259 Digital Signal Interface Module (Option 003/004)Clock TimingClock Timing for Parallel DataSome c

Página 195

260 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Clock Timing Figure 10-4 Clock Sample Timing for

Página 196 - Example: Gated Triggering

Agilent X-Series Signal Generators User’s Guide 261 Digital Signal Interface Module (Option 003/004)Clock Timing1 Sample Period4 Clocks Per Sample4

Página 197

262 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Clock Timing Clock Timing for Parallel Interleave

Página 198 - Example: External Triggering

Agilent X-Series Signal Generators User’s Guide 263 Digital Signal Interface Module (Option 003/004)Clock Timing1 Sample Period4 Clocks Per Sample4

Página 199 - Available only when

264 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Clock Timing Clock Timing for Serial DataFigure 1

Página 200 - How Power Peaks Develop

Agilent X-Series Signal Generators User’s Guide 265 Digital Signal Interface Module (Option 003/004)Connecting the Clock Source and the Device Under

Página 201 - Clipping a Waveform

14 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)2. EXT 1 & EX

Página 202

266 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Connecting the Clock Source and the Device Under

Página 203 - Figure 8-9 Circular Clipping

Agilent X-Series Signal Generators User’s Guide 267 Digital Signal Interface Module (Option 003/004)Connecting the Clock Source and the Device Under

Página 204

268 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Data Types Data TypesThe following block diagram

Página 205

Agilent X-Series Signal Generators User’s Guide 269 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Output ModeOperat

Página 206 - Configuring Circular Clipping

270 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Output Mode Press

Página 207

Agilent X-Series Signal Generators User’s Guide 271 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Output ModeChoosi

Página 208 - Scaling a Waveform

272 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Output Mode setup.

Página 209

Agilent X-Series Signal Generators User’s Guide 273 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Output ModeFigure

Página 210

274 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Output Mode select

Página 211

Agilent X-Series Signal Generators User’s Guide 275 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Output ModeFigure

Página 212 - Setting Waveform Scaling

Agilent X-Series Signal Generators User’s Guide 15 Signal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)panel or over th

Página 213

276 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Output Mode source

Página 214

Agilent X-Series Signal Generators User’s Guide 277 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Output ModeThis e

Página 215

278 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Output Mode b. Pre

Página 216 - LO/carrier feedthrough

Agilent X-Series Signal Generators User’s Guide 279 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Output ModeTiming

Página 217

280 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Input Mode Operati

Página 218

Agilent X-Series Signal Generators User’s Guide 281 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Input ModeFigure

Página 219

282 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Input Mode Selecti

Página 220

Agilent X-Series Signal Generators User’s Guide 283 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Input Mode2. Sele

Página 221

284 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Input Mode module.

Página 222 - I/Q Adjustments

Agilent X-Series Signal Generators User’s Guide 285 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Input Mode• clock

Página 223

Contents Agilent X-Series Signal Generators User’s Guide iii1 Signal Generator OverviewSignal Generator Features . . . . . . . . . . . . . . . . . .

Página 224 - I/Q Calibration

16 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)Digital Modulatio

Página 225

286 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Input Mode 4. Pres

Página 226 - Using the Equalization Filter

Agilent X-Series Signal Generators User’s Guide 287 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Input Mode9. Pres

Página 227

288 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Input Mode Figure

Página 228 - Figure 8-17 Filter Menu

Agilent X-Series Signal Generators User’s Guide 289 Digital Signal Interface Module (Option 003/004)Operating the N5102A Module in Input Mode2. Pres

Página 229

290 Agilent X-Series Signal Generators User’s Guide Digital Signal Interface Module (Option 003/004) Operating the N5102A Module in Input Mode 6. Pres

Página 230

Agilent X-Series Signal Generators User’s Guide 29111 BERT (Option UN7)The bit error rate test (BERT) capability allows you to perform bit error rate

Página 231 - Figure 8-19

292 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Bit Error Rate Tester–Option UN7 Bit Error Rate Tester–Option UN7The bit error r

Página 232

Agilent X-Series Signal Generators User’s Guide 293 BERT (Option UN7)Bit Error Rate Tester–Option UN7Figure 11-2•When the Clock Gate Off On softkey

Página 233 - Figure 8-21

294 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Bit Error Rate Tester–Option UN7 Figure 11-3

Página 234 - These keys manage the table

Agilent X-Series Signal Generators User’s Guide 295 BERT (Option UN7)Bit Error Rate Tester–Option UN7Clock Delay FunctionIn this example, the clock

Página 235 - (apodization function) for

Agilent X-Series Signal Generators User’s Guide 17 Signal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)BB TRIG 1 &

Página 236 - Modifying the Coefficients

296 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Bit Error Rate Tester–Option UN7 Gate Delay Function in the Clock ModeTo use thi

Página 237 - Storing the Filter to Memory

Agilent X-Series Signal Generators User’s Guide 297 BERT (Option UN7)Bit Error Rate Tester–Option UN7TriggeringThis section describes the operating

Página 238

298 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Bit Error Rate Tester–Option UN7 In this example, the triggering sequence is whe

Página 239

Agilent X-Series Signal Generators User’s Guide 299 BERT (Option UN7)Bit Error Rate Tester–Option UN7In this example, synchronization occurs after r

Página 240

300 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Bit Error Rate Tester–Option UN7 In this example, the triggering sequence is whe

Página 241

Agilent X-Series Signal Generators User’s Guide 301 BERT (Option UN7)Bit Error Rate Tester–Option UN7Special Pattern Ignore FunctionThe special patt

Página 242

302 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Bit Error Rate Tester–Option UN7 Figure 11-12 Repeat Measurements ExampleTesting

Página 243 - There can be 1 to 15

Agilent X-Series Signal Generators User’s Guide 303 BERT (Option UN7)Bit Error Rate Tester–Option UN7• T2 is a firmware handling time measured from

Página 244

304 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Verifying BERT Operation Verifying BERT Operation The following procedures verif

Página 245

Agilent X-Series Signal Generators User’s Guide 305 BERT (Option UN7)Verifying BERT OperationFigure 11-14 Rear Panel Connectors for BERT Configurati

Página 246

18 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)AUX I/O Connector

Página 247

306 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Verifying BERT Operation Figure 11-15 Self-Test Mode Results

Página 248

Agilent X-Series Signal Generators User’s Guide 307 BERT (Option UN7)Verifying BERT OperationMeasurement Example Using Custom Digital Modulation (Re

Página 249

308 Agilent X-Series Signal Generators User’s Guide BERT (Option UN7) Verifying BERT Operation Figure 11-16 Configuration Using Custom Digital Modulat

Página 250 - Real-Time Applications

Agilent X-Series Signal Generators User’s Guide 30912 Real–Time Phase Noise Impairments (Option 432)Before using this information, you should be fam

Página 251 - Waveform Licensing

310 Agilent X-Series Signal Generators User’s GuideReal–Time Phase Noise Impairments (Option 432) Real–Time Phase Noise Impairment Real–Time Phase Noi

Página 252

Agilent X-Series Signal Generators User’s Guide 311 Real–Time Phase Noise Impairments (Option 432)The Agilent X-Series Phase Noise Shape and Additive

Página 253

312 Agilent X-Series Signal Generators User’s GuideReal–Time Phase Noise Impairments (Option 432) The Agilent X-Series Phase Noise Shape and Additive

Página 254

Agilent X-Series Signal Generators User’s Guide 313 Real–Time Phase Noise Impairments (Option 432)Understanding the Phase Noise AdjustmentsUnderstand

Página 255

314 Agilent X-Series Signal Generators User’s GuideReal–Time Phase Noise Impairments (Option 432) DAC Over–Range Conditions and Scaling DAC Over–Range

Página 256 - Figure 8-36 Add Waveform

31513 Custom Digital Modulation (Option 431)Before using this information, you should be familiar with the basic operation of the signal generator.

Página 257

Agilent X-Series Signal Generators User’s Guide 19 Signal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)Markers (pins 1-

Página 258 - Figure 8-39

316 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Custom Modulation Custom Modulation For creating custom

Página 259

Agilent X-Series Signal Generators User’s Guide 317 Custom Digital Modulation (Option 431)Custom ModulationFigure 13-1 ARB Custom Modulation Soft

Página 260 - Figure 9-6 on page 250

318 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Custom Modulation Figure 13-2 Quick Setup Softkeyspage 3

Página 261

Agilent X-Series Signal Generators User’s Guide 319 Custom Digital Modulation (Option 431)Custom ModulationFigure 13-3 Mod Type Softkeyspage 353p

Página 262

320 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Custom Modulation Figure 13-4 Custom Modulation Formats

Página 263

Agilent X-Series Signal Generators User’s Guide 321 Custom Digital Modulation (Option 431)Custom ModulationFigure 13-6 Real-Time Custom Modulati

Página 264

322 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Custom Modulation Figure 13-7 Modulation Setup Softkeys

Página 265

Agilent X-Series Signal Generators User’s Guide 323 Custom Digital Modulation (Option 431)Custom ModulationFigure 13-8 Modulation Type Softkeysp

Página 266

324 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Creating and Using Bit Files Creating and Using Bit File

Página 267 - Clock Timing

Agilent X-Series Signal Generators User’s Guide 325 Custom Digital Modulation (Option 431)Creating and Using Bit FilesFigure 13-9 Data Selection

Página 268 - Most significant bit

20 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)Table 1-1 AUX I/O

Página 269

326 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Creating and Using Bit Files Figure 13-10 Bit File Displ

Página 270 - Clock Source

Agilent X-Series Signal Generators User’s Guide 327 Custom Digital Modulation (Option 431)Creating and Using Bit FilesFigure 13-11 Entering Bit V

Página 271 - Common Frequency Reference

328 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Creating and Using Bit Files Recalling a User FileIn thi

Página 272

Agilent X-Series Signal Generators User’s Guide 329 Custom Digital Modulation (Option 431)Creating and Using Bit FilesInverting Bit Values1. Pres

Página 273

330 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Customized Burst Shape Curves Using Customized Bur

Página 274 - 1 Clock Per Sample

Agilent X-Series Signal Generators User’s Guide 331 Custom Digital Modulation (Option 431)Using Customized Burst Shape CurvesBurst shape maximum

Página 275 - 2 Clocks Per Sample

332 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Customized Burst Shape Curves The signal generator

Página 276 - 1 Sample Period

Agilent X-Series Signal Generators User’s Guide 333 Custom Digital Modulation (Option 431)Using Customized Burst Shape CurvesFigure 13-14 Burst S

Página 277

334 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Customized Burst Shape Curves Entering Sample Valu

Página 278 - Clock Timing for Serial Data

Agilent X-Series Signal Generators User’s Guide 335 Custom Digital Modulation (Option 431)Using Customized Burst Shape CurvesDisplay the Burst Sh

Página 279

Agilent X-Series Signal Generators User’s Guide 21 Signal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)17AUX(9) BER Tes

Página 280

336 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Customized Burst Shape Curves 2. Press Mode >

Página 281 - N5102A module

Agilent X-Series Signal Generators User’s Guide 337 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorUsing the Arbitra

Página 282 - Data Types

338 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Configuring the R

Página 283 - Select either PXB or N5102A

Agilent X-Series Signal Generators User’s Guide 339 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorCreating a Custom

Página 284

340 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Figure 13-19 Modi

Página 285

Agilent X-Series Signal Generators User’s Guide 341 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorSelecting the Fil

Página 286 - Selecting the Data Parameters

342 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Figure 13-20 Stor

Página 287

Agilent X-Series Signal Generators User’s Guide 343 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorRecalling a Custo

Página 288 - softkey

344 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Defining a Modula

Página 289

Agilent X-Series Signal Generators User’s Guide 345 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorFigure 13-22 FSK

Página 290

22 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5171B, N5172B, N5181B, & N5182B)32GND GND GND GND

Página 291

346 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Figure 13-23 I/Q

Página 292

Agilent X-Series Signal Generators User’s Guide 347 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorUtilizing this I/

Página 293 - Generating Digital Data

348 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Figure 13- 26 sho

Página 294

Agilent X-Series Signal Generators User’s Guide 349 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorFigure 13-27 8PSK

Página 295

350 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Creating a Custom

Página 296 - Selecting the Input Direction

Agilent X-Series Signal Generators User’s Guide 351 Custom Digital Modulation (Option 431)Using the Arbitrary Waveform GeneratorCreating a Multic

Página 297 - Configuring the Clock Signal

352 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using the Arbitrary Waveform Generator Storing a Custom

Página 298 - 10 MHz and above 200 MHz

Agilent X-Series Signal Generators User’s Guide 353 Custom Digital Modulation (Option 431)Using Finite Impulse Response (FIR) Filters with Custom

Página 299

354 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Finite Impulse Response (FIR) Filters with Custom

Página 300

Agilent X-Series Signal Generators User’s Guide 355 Custom Digital Modulation (Option 431)Using Finite Impulse Response (FIR) Filters with Custom

Página 301

Agilent X-Series Signal Generators User’s Guide 23 Signal Generator OverviewRear Panel Overview (N5173B & N5183B)Rear Panel Overview (N5173B &

Página 302

356 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Finite Impulse Response (FIR) Filters with Custom

Página 303

Agilent X-Series Signal Generators User’s Guide 357 Custom Digital Modulation (Option 431)Using Finite Impulse Response (FIR) Filters with Custom

Página 304 - Digital Data

358 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Using Finite Impulse Response (FIR) Filters with Custom

Página 305 - 11 BERT (Option UN7)

Agilent X-Series Signal Generators User’s Guide 359 Custom Digital Modulation (Option 431)Modifying a FIR Filter Using the FIR Table EditorFigure

Página 306 - Clock Gate Function

360 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Modifying a FIR Filter Using the FIR Table Editor Loadin

Página 307 - Clock/Gate Delay Function

Agilent X-Series Signal Generators User’s Guide 361 Custom Digital Modulation (Option 431)Modifying a FIR Filter Using the FIR Table Editor5. Pre

Página 308 - Figure 11-3

362 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Differential Encoding Refer to Figure 13- 40 on page 361

Página 309 - Clock Delay Function

Agilent X-Series Signal Generators User’s Guide 363 Custom Digital Modulation (Option 431)Differential EncodingThe following illustration shows a

Página 310 - BERT (Option UN7)

364 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Differential Encoding NOTE The number of bits per symbol

Página 311 - Triggering

Agilent X-Series Signal Generators User’s Guide 365 Custom Digital Modulation (Option 431)Differential EncodingThese symbol table offsets will re

Página 312 - Figure 11-8

24 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5173B & N5183B)2. EXT 1 & EXT 23. LF OUT4. SW

Página 313 - BERT (Option UN7)

366 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Differential Encoding As you can see from the previous i

Página 314 - Data Processing

Agilent X-Series Signal Generators User’s Guide 367 Custom Digital Modulation (Option 431)Differential EncodingThis loads a default 4QAM I/Q modu

Página 315 - Repeat Measurements

368 Agilent X-Series Signal Generators User’s Guide Custom Digital Modulation (Option 431) Differential Encoding Editing the Differential State Map

Página 316 - Testing Signal Definitions

36914 Multitone and Two–Tone Waveforms (Option 430)Before using this information, you should be familiar with the basic operation of the signal genera

Página 317

370 Agilent X-Series Signal Generators User’s GuideMultitone and Two–Tone Waveforms (Option 430) Using Two–Tone Modulation • Changing the Alignment of

Página 318 - Verifying BERT Operation

Agilent X-Series Signal Generators User’s Guide 371 Multitone and Two–Tone Waveforms (Option 430)Using Two–Tone Modulation4. Press Mode > More &

Página 319

372 Agilent X-Series Signal Generators User’s GuideMultitone and Two–Tone Waveforms (Option 430) Using Two–Tone Modulation Figure 14-2Minimizing Carri

Página 320

Agilent X-Series Signal Generators User’s Guide 373 Multitone and Two–Tone Waveforms (Option 430)Using Two–Tone Modulation8. Create a marker and plac

Página 321

374 Agilent X-Series Signal Generators User’s GuideMultitone and Two–Tone Waveforms (Option 430) Using Two–Tone Modulation NOTE Whenever a change is m

Página 322

Agilent X-Series Signal Generators User’s Guide 375 Multitone and Two–Tone Waveforms (Option 430)Using Multitone ModulationUsing Multitone Modulation

Página 323

Agilent X-Series Signal Generators User’s Guide 25 Signal Generator OverviewRear Panel Overview (N5173B & N5183B)panel or over the remote interfac

Página 324

376 Agilent X-Series Signal Generators User’s GuideMultitone and Two–Tone Waveforms (Option 430) Using Multitone Modulation Figure 14-5 5. Press Done

Página 325

Agilent X-Series Signal Generators User’s Guide 377 Multitone and Two–Tone Waveforms (Option 430)Using Multitone Modulation2. Set the output amplitud

Página 326

378 Agilent X-Series Signal Generators User’s GuideMultitone and Two–Tone Waveforms (Option 430) Using Multitone Modulation Recalling a Multitone Wave

Página 327

Agilent X-Series Signal Generators User’s Guide 37915 Working in a Secure EnvironmentIf you are using the instrument in a secure environment, you ma

Página 328

380 Agilent X-Series Signal Generators User’s Guide Working in a Secure EnvironmentUsing Secure DisplayUsing Secure DisplayThis function prevents una

Página 329

Agilent X-Series Signal Generators User’s Guide 38116 Troubleshooting• Display on page 382• Signal Generator Lock–Up on page 382• RF Output on page

Página 330 - Custom Modulation

382 Agilent X-Series Signal Generators User’s GuideTroubleshooting Display DisplayThe Display is Too Dark to ReadBrightness may be set to minimum. Use

Página 331

Agilent X-Series Signal Generators User’s Guide 383 TroubleshootingRF OutputRF Output Power too Low•If the AMPLITUDE area of the display shows the OFF

Página 332

384 Agilent X-Series Signal Generators User’s GuideTroubleshooting RF Output Signal Loss While Working with a MixerCAUTION To avoid damaging or degrad

Página 333 - Figure 13-3 Mod Type Softkeys

Agilent X-Series Signal Generators User’s Guide 385 TroubleshootingRF OutputThe solution at right shows a similar configuration with the addition of a

Página 334

Contentsiv Agilent X-Series Signal Generators User’s Guide2. EXT 1 & EXT 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 335

26 Agilent X-Series Signal Generators User’s GuideSignal Generator OverviewRear Panel Overview (N5173B & N5183B)15. Z AXIS OUTPUTThis female BNC c

Página 336

386 Agilent X-Series Signal Generators User’s GuideTroubleshooting Sweep SweepCannot Turn Off SweepPress Sweep > Sweep > Off.Sweep Appears Stal

Página 337

Agilent X-Series Signal Generators User’s Guide 387 TroubleshootingInternal Media Data StorageInternal Media Data StorageInstrument State Saved but th

Página 338 - Creating and Using Bit Files

388 Agilent X-Series Signal Generators User’s GuideTroubleshooting Error Messages Error MessagesError Message TypesEvents do not generate more than on

Página 339 - , Binary

Agilent X-Series Signal Generators User’s Guide 389 TroubleshootingFront Panel TestsFront Panel TestsSet all display pixels to the selected color. To

Página 340 - (in Hex)

390 Agilent X-Series Signal Generators User’s GuideTroubleshooting Self Test Overview Self Test OverviewThe self test is a series of internal tests th

Página 341

Agilent X-Series Signal Generators User’s Guide 391 TroubleshootingSelf Test OverviewFor details on each key, use key help as described on page 44.Aut

Página 342 - Recalling a User File

392 Agilent X-Series Signal Generators User’s GuideTroubleshooting Self Test Overview

Página 343

Agilent X-Series Signal Generators User’s Guide 393 TroubleshootingLicensesLicensesA Time–Based License Quits Working• The instrument’s time or date m

Página 344 - Understanding Burst Shape

394 Agilent X-Series Signal Generators User’s GuideTroubleshooting Contacting Agilent Technologies

Página 345

Agilent X-Series Signal Generators User’s Guide 395GlossaryAActive Entry The currently selected, and therefore editable, entry or parameterARB Arbitr

Página 346

Agilent X-Series Signal Generators User’s Guide 272 Setting Preferences & Enabling OptionsThe Utility menu provides access to both user and rem

Página 347

396 Agilent X-Series Signal Generators User’s Guidestored. IP Internet protocol. The network layer for the TCP/IP protocol suite widely used on Ethe

Página 348

Agilent X-Series Signal Generators User’s Guide 397peak value. SSoftkey A button located along the instrument’s display that performs whatever functi

Página 349 - Figure 13-16 Burst Shape

398 Agilent X-Series Signal Generators User’s Guide

Página 350 - 4. Press Select File

Agilent X-Series Signal Generators User’s Guide 399IndexSymbols, 214ΦMannunciator, 10dc offset, removing, 79hardkey, 75softkeys, 75, 79# points softk

Página 351

400 Agilent X-Series Signal Generators User’s GuideIndexASK softkey, 319, 323, 325, 326, 327, 328, 329, 333ATTEN HOLD annunciator, 10Atten/ALC Control

Página 352 - 3. Press RF On/Off

Agilent X-Series Signal Generators User’s Guide 401IndexError Queue(s), 73Header, 155Text, 45clippingcircular, 189, 192rectangular, 190, 193softkeys,

Página 353

402 Agilent X-Series Signal Generators User’s GuideIndexsystem, restoring, 44Default softkey, 318, 322delayI/Q, 208multiple BBG sync, 228Delete softke

Página 354 - Modulation Type > Select

Agilent X-Series Signal Generators User’s Guide 403IndexErase All, 379Erase and Sanitize All, 379ERR annunciator, 11Error hardkey, 73error messages,

Página 355

404 Agilent X-Series Signal Generators User’s GuideIndexhardkey, 75softkeys, 75formula, skew discrete steps, 264Free Run softkey, 51, 126, 179Free- Ru

Página 356

Agilent X-Series Signal Generators User’s Guide 405IndexinterfaceGPIB, 32LAN, 33internalreference oscillator, using, 31Internal Baseband Adjustments

Página 357

28 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options User Preferences User PreferencesFrom the Utility menu, y

Página 358 - Defining a Modulation

406 Agilent X-Series Signal Generators User’s GuideIndexmarkers, aligning signal, 162markers, waveform, 161–177mediaBBG, 395erasing, 379Flash Drive, 7

Página 359 - Figure 13-22 FSK Table Editor

Agilent X-Series Signal Generators User’s Guide 407IndexOOFFS annunciator, 11offset, 143offset binary use, 274, 289offsetsbaseband frequency, 200I/Q,

Página 360 - Figure 13-24 I/Q Table Editor

408 Agilent X-Series Signal Generators User’s GuideIndexusing, 44Preset softkeysLanguage, 29, 55, 98Preset, 29Prev REG softkey, 128Prev SEQ softkey, 1

Página 361

Agilent X-Series Signal Generators User’s Guide 409Indexoutputconfiguring, 48, 7leveling, external, 110–117troubleshooting, 382RF During Power Search

Página 362

410 Agilent X-Series Signal Generators User’s GuideIndexdefinition of, 397help on, 44label area, 12, 6See also specific keysource settled signal, 52So

Página 363

Agilent X-Series Signal Generators User’s Guide 411IndexUunfiltered & filtered samples, 274, 289UNLEVEL annunciator, 11unleveled operation, 118UN

Página 364

412 Agilent X-Series Signal Generators User’s GuideIndex

Página 365

Agilent X-Series Signal Generators User’s Guide 29Setting Preferences & Enabling OptionsUser PreferencesPower On and PresetSelect the GPIB langu

Página 366

30 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options User Preferences Front Panel Knob ResolutionSetting Time

Página 367 - Opens the IS–95

Agilent X-Series Signal Generators User’s Guide 31Setting Preferences & Enabling OptionsUpgrading Firmwaretime back. In this case, you can re- e

Página 368

32 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options Remote Operation Preferences Remote Operation Preferences

Página 369

Agilent X-Series Signal Generators User’s Guide 33Setting Preferences & Enabling OptionsRemote Operation PreferencesConfiguring the LAN Interfac

Página 370

34 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options Remote Operation Preferences Enabling LAN Services: “Brow

Página 371 - Figure 13-34

Agilent X-Series Signal Generators User’s Guide 35Setting Preferences & Enabling OptionsRemote Operation PreferencesConfiguring the Remote Langu

Página 372 - Figure 13-36

Contents Agilent X-Series Signal Generators User’s Guide vSetting Time and Date. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 373

36 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options Remote Operation Preferences Figure 2-2 N5173B/83BUtility

Página 374

Agilent X-Series Signal Generators User’s Guide 37Setting Preferences & Enabling OptionsRemote Operation PreferencesConfiguring the Preset Langu

Página 375

38 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options Remote Operation Preferences Figure 2-4 N5173B/83BUtility

Página 376 - Differential Encoding

Agilent X-Series Signal Generators User’s Guide 39Setting Preferences & Enabling OptionsEnabling an OptionEnabling an OptionThere are two ways t

Página 377

40 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options Enabling an Option Viewing Options and LicensesUtility &g

Página 378

Agilent X-Series Signal Generators User’s Guide 41Setting Preferences & Enabling OptionsHardware Assembly Installation and Removal Softkeys Hard

Página 379 - Data Value 00000011

42 Agilent X-Series Signal Generators User’s GuideSetting Preferences & Enabling Options Hardware Assembly Installation and Removal Softkeys

Página 380 - Using Differential Encoding

Agilent X-Series Signal Generators User’s Guide 433 Basic OperationThis chapter introduces fundamental front panel operation. For information on re

Página 381 - Figure 13-42

44 Agilent X-Series Signal Generators User’s Guide Basic Operation Presetting the Signal Generator Presetting the Signal GeneratorViewing Key Descript

Página 382 - −1. The symbol rotates

Agilent X-Series Signal Generators User’s Guide 45 Basic OperationEntering and Editing Numbers and TextEntering and Editing Numbers and TextEntering

Página 383 - Using Two–Tone Modulation

Contentsvi Agilent X-Series Signal Generators User’s GuideWorking with Instrument State Files . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 384 - Creating a Two–Tone Waveform

46 Agilent X-Series Signal Generators User’s Guide Basic Operation Entering and Editing Numbers and Text Example: Using a Table EditorTable editors si

Página 385 - For details on

Agilent X-Series Signal Generators User’s Guide 47 Basic OperationSetting Frequency and Power (Amplitude)Setting Frequency and Power (Amplitude)Figu

Página 386

48 Agilent X-Series Signal Generators User’s Guide Basic Operation Setting Frequency and Power (Amplitude) Example: Configuring a 700 MHz, −20 dBm Con

Página 387 - For details on each

Agilent X-Series Signal Generators User’s Guide 49 Basic OperationSetting ALC Bandwidth ControlFigure 3-2 Using an External Reference OscillatorSett

Página 388

50 Agilent X-Series Signal Generators User’s Guide Basic Operation Configuring a Swept Output Configuring a Swept OutputThe signal generator has two m

Página 389 - Using Multitone Modulation

Agilent X-Series Signal Generators User’s Guide 51 Basic OperationConfiguring a Swept OutputFigure 3-4 Sweep SoftkeysSweep without waiting for a tr

Página 390 - Generating the Waveform

52 Agilent X-Series Signal Generators User’s Guide Basic Operation Configuring a Swept Output Routing SignalsSweep > More > More > Route Conn

Página 391

Agilent X-Series Signal Generators User’s Guide 53 Basic OperationConfiguring a Swept OutputFigure 3-6 Sweep SoftkeysExample: Configuring a Continuo

Página 392

54 Agilent X-Series Signal Generators User’s Guide Basic Operation Configuring a Swept Output 4. Sweep both frequency and amplitude: Press Return >

Página 393

Agilent X-Series Signal Generators User’s Guide 55 Basic OperationConfiguring a Swept OutputList SweepList sweep enables you to enter frequencies an

Página 394 - Using Secure Display

Contents Agilent X-Series Signal Generators User’s Guide viiUsing Free Run, Step Dwell, and Timer Trigger . . . . . . . . . . . . . . . . . . . . . .

Página 395 - 16 Troubleshooting

56 Agilent X-Series Signal Generators User’s Guide Basic Operation Configuring a Swept Output Example: Configuring a List Sweep Using Step Sweep Data1

Página 396 - RF Output

Agilent X-Series Signal Generators User’s Guide 57 Basic OperationConfiguring a Swept OutputExample: Editing List Sweep PointsIf you are not familia

Página 397 - Distortion

58 Agilent X-Series Signal Generators User’s Guide Basic Operation Configuring a Swept Output 13. As desired, repeat step 12 for the remaining points

Página 398 - Troubleshooting

Agilent X-Series Signal Generators User’s Guide 59 Basic OperationModulating the Carrier SignalExample: Manual Control of Sweep1. Set up either a st

Página 399 - Troubleshooting

60 Agilent X-Series Signal Generators User’s Guide Basic Operation Modulating the Carrier Signal 3. Enable modulation of the RF output: Press the Mod

Página 400 - Sweep Appears Stalled

Agilent X-Series Signal Generators User’s Guide 61 Basic OperationWorking with FilesSimultaneous ModulationNOTE The Agilent X- Series signal generat

Página 401 - USB Media Data Storage

62 Agilent X-Series Signal Generators User’s Guide Basic Operation Working with Files File SoftkeysInstrument operating parameters (see page 68).Sweep

Página 402 - Error Messages

Agilent X-Series Signal Generators User’s Guide 63 Basic OperationWorking with FilesARB File SoftkeysViewing a List of Stored FilesThe information i

Página 403 - Front Panel Tests

64 Agilent X-Series Signal Generators User’s Guide Basic Operation Working with Files Viewing a list of Files Stored on USB MediaWith USB media connec

Página 404 - Self Test Overview

Agilent X-Series Signal Generators User’s Guide 65 Basic OperationWorking with FilesStoring a FileSeveral menus enable you to store instrument param

Página 405

Contentsviii Agilent X-Series Signal Generators User’s GuideUsing the RF Blanking Marker Function. . . . . . . . . . . . . . . . . . . . . . . . . .

Página 406

66 Agilent X-Series Signal Generators User’s Guide Basic Operation Working with Files Loading (Recalling) a Stored FileThere are several ways to load

Página 407 - Licenses

Agilent X-Series Signal Generators User’s Guide 67 Basic OperationWorking with FilesMoving a File from One Media to AnotherUse the USB Media Manager

Página 408

68 Agilent X-Series Signal Generators User’s Guide Basic Operation Working with Files Working with Instrument State Files• Saving an Instrument State

Página 409 - Glossary

Agilent X-Series Signal Generators User’s Guide 69 Basic OperationWorking with FilesSaving an Instrument State1. Preset the signal generator and set

Página 410

70 Agilent X-Series Signal Generators User’s Guide Basic Operation Working with Files Recalling an Instrument State and Associated Waveform File 1. En

Página 411

Agilent X-Series Signal Generators User’s Guide 71 Basic OperationWorking with FilesMoving or Copying a Stored Instrument StateFigure 3-9 Instrument

Página 412

72 Agilent X-Series Signal Generators User’s Guide Basic Operation Working with Files Selecting the Default Storage MediaYou can configure the signal

Página 413 - Numerics

Agilent X-Series Signal Generators User’s Guide 73 Basic OperationReading Error MessagesReading Error MessagesIf an error condition occurs, the sign

Página 414

74 Agilent X-Series Signal Generators User’s Guide Basic Operation Reading Error Messages

Página 415

Agilent X-Series Signal Generators User’s Guide 754 Using Analog Modulation (Option UNT)NOTE The Mod On/Off hardkey and LED functionality are only v

Página 416

Contents Agilent X-Series Signal Generators User’s Guide ixMaking Changes to the Multiple Synchronization Setup and Resynchronizing the Master/Slave

Página 417

76 Agilent X-Series Signal Generators User’s GuideUsing Analog Modulation (Option UNT)Analog Modulation Waveforms Analog Modulation WaveformsThe signa

Página 418 - , 122, 200

Agilent X-Series Signal Generators User’s Guide 77 Using Analog Modulation (Option UNT)Analog Modulation SourcesFigure 4-1 Analog Modulation Softkeys

Página 419

78 Agilent X-Series Signal Generators User’s GuideUsing Analog Modulation (Option UNT)Using an Internal Modulation Source Using an Internal Modulation

Página 420

Agilent X-Series Signal Generators User’s Guide 79 Using Analog Modulation (Option UNT)Using an External Modulation SourceUsing an External Modulatio

Página 421 - , 274, 289

80 Agilent X-Series Signal Generators User’s GuideUsing Analog Modulation (Option UNT)Using an External Modulation Source NOTE For frequencies between

Página 422

Agilent X-Series Signal Generators User’s Guide 81 Using Analog Modulation (Option UNT)Configuring the LF Output (Option 303)Configuring the LF Outpu

Página 423

82 Agilent X-Series Signal Generators User’s GuideUsing Analog Modulation (Option UNT)Configuring the LF Output (Option 303) The RF On/Off hardkey do

Página 424

Agilent X-Series Signal Generators User’s Guide 83 Using Analog Modulation (Option UNT)Configuring the LF Output (Option 303)Configuring the LF Outpu

Página 425

84 Agilent X-Series Signal Generators User’s GuideUsing Analog Modulation (Option UNT)Configuring the LF Output (Option 303)

Página 426

Agilent X-Series Signal Generators User’s Guide 855 Optimizing PerformanceBefore using this information, you should be familiar with the basic opera