Command Reference
Pulse Modulation Subsystem ([:SOURce])
Chapter 4 291
:PULM:INTernal[1]:PWIDth
Supported PSG-A Series
[:SOURce]:PULM:INTernal[1]:PWIDth <num>[<time suffix>]|UP|DOWN
[:SOURce]:PULM:INTernal[1]:PWIDth?
This command sets the pulse width for the internally generated pulse modulation
source.
The optional variable [<time suffix>] accepts nS (nano-seconds) to S (seconds).
*RST
+
1.00000000E
006
Range 10nS to (pulse period
20 nS)
Key Entry
Pulse Width
Remarks If the entered value for the pulse width is equal to or greater than the
value for the pulse period, the pulse width will change to a value that
is less than the pulse period.
Refer to “:PULM:INTernal[1]:PWIDth:STEP for setting the value
associated with the UP and DOWN choices.
:PULM:INTernal[1]:PWIDth:STEP
Supported PSG-A Series
[:SOURce]:PULM:INTernal[1]:PWIDth:STEP <num>[<time suffix>]
[:SOURce]:PULM:INTernal[1]:PWIDth:STEP?
This command sets the step increment for the pulse width.
The optional variable [<time suffix>] accepts nS (nano-seconds) to S (seconds).
*RST
+
1.00000000E
006
Range 10nS to (pulse period
20 nS)
Key Entry N/A
Remarks The value set by this command is used by the UP and DOWN choices
for the pulse width command. Refer to “:PULM:INTernal[1]:PWIDth”
for more information.