Command Reference
Power Subsystem ([:SOURce])
Chapter 4 279
Power Subsystem ([:SOURce])
:POWer:ALC:BANDwidth|BWIDth
Supported All
[:SOURce]:POWer:ALC:BANDwidth|BWIDth <num>[<freq suffix>]
[:SOURce]:POWer:ALC:BANDwidth|BWIDth?
This command sets the bandwidth of the automatic leveling control (ALC) loop.
*RST 100.0
Remarks N/A
:POWer:ALC:BANDwidth|BWIDth:AUTO
Supported All
[:SOURce]:POWer:ALC:BANDwidth|BWIDth:AUTO ON|OFF|1|0
[:SOURce]:POWer:ALC:BANDwidth|BWIDth:AUTO?
This command sets the state of the ALC automatic bandwidth capability.
*RST 0
Key Entry
Auto
Remarks N/A
Choices <num>[<freq suffix>]: 100HZ 1kHZ 10kHZ 100kHZ
Key Entry
100 Hz 1 kHz 10 kHz 100 kHz
Choices ON OFF 1 0