Command Reference
Frequency Modulation Subsystem ([:SOURce])
Chapter 4 247
:FM[1]|2:INTernal[1]:FREQuency:ALTernate:AMPLitude:PERCent
Supported PSG-A Series
[:SOURce]:FM[1]|2:INTernal[1]:FREQuency:ALTernate:AMPLitude:
PERCent <val><unit>
[:SOURce]:FM[1]|2:INTernal[1]:FREQuency:ALTernate:AMPLitude:PERCent?
This command sets the amplitude of the second tone for a dual-sine waveform as a
percentage of the total amplitude. For example, if the second tone makes up 30% of the
total amplitude, then the first tone is 70% of the total amplitude.
*RST
+
5.00000000E
+
001
Range 0–100PCT
Key Entry
FM Tone 2 Ampl Percent Of Peak
Remarks Refer to “:FM[1]|2:INTernal[1]|2:FUNCtion:SHAPe” on page 250 for
the waveform selection.
:FM[1]|2:INTernal[1]:SWEep:RATE
Supported PSG-A Series
[:SOURce]:FM[1]|2:INTernal[1]:SWEep:RATE <val><unit>
[:SOURce]:FM[1]|2:INTernal[1]:SWEep:RATE?
This command sets the sweep rate for the swept-sine waveform.
The variable <val> has a minimum resolution of 0.5 hertz.
*RST
+
4.00000000E
+
002
Range 0.5HZ–100kHZ
Key Entry
FM Sweep Rate
Remarks Refer to “:FM[1]|2:INTernal[1]|2:FUNCtion:SHAPe” on page 250 for
the waveform selection.