Agilent Technologies InfiniiVision 6000 Series Manual de Serviço Página 592

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 934
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 591
592 Agilent InfiniiVision 6000 Series Oscilloscopes Programmer's Guide
5 Commands by Subsystem
:TRIGger:SEQuence:TRIGger
(see page 798)
Command Syntax
:TRIGger:SEQuence:TRIGger <value>
<value> ::={PATTern2,ENTered | PATTern2,EXITed | EDGE2
| PATTern2,AND,EDGE2 | EDGE2,COUNt | EDGE2,COUNt,NREFind}
The :TRIGger:SEQuence:TRIGger command specifies the trigger stage of a
sequence trigger. The sequence commands set various search terms. After
all of these are found in sequence, the trigger condition itself is searched
for. This command accepts three program data parameters; you can use
NONE to fill out the parameter list (for example, "EDGE2,NONE,NONE").
PATTern2 is specified with the :TRIGger:SEQuence:PATTern command.
EDGE2 is specified with the :TRIGger:SEQuence:EDGE command. COUNt is
specified with the :TRIGger:SEQuence:COUNt command.
Query Syntax
:TRIGger:SEQuence:TRIGger?
The :TRIGger:SEQuence:TRIGger? query returns the trigger stage
specification for a sequence trigger. NONE is returned for unused
parameters.
Return Format
<trigger_value><NL>
<trigger_value> ::= {PATT2,ENT,NONE | PATT2,EXIT,NONE
| EDGE2,NONE,NONE | PATT2,AND,EDGE2
| EDGE2,COUN,NONE | EDGE2,COUN,NREF}
See Also "Introduction to :TRIGger Commands" on page 479
":TRIGger:SEQuence:PATTern" on page 589
":TRIGger:SEQuence:EDGE" on page 587
":TRIGger:SEQuence:COUNt" on page 586
":TRIGger:SEQuence:FIND" on page 588
":TRIGger:SEQuence:RESet" on page 590
":TRIGger:SEQuence:RESet" on page 590