Agilent 4294A
Precision Impedance Analyzer
40 Hz to 110 MHz
Technical Overview
New generation precision impedance analyzer for functionality and efficiency in engineering
Vista de página 0
1 2 3 4 5 6 ... 11 12

Resumo do Conteúdo

Página 1 - 40 Hz to 110 MHz

Agilent 4294A Precision Impedance Analyzer40 Hz to 110 MHzTechnical OverviewNew generation precision impedance analyzer for functionality and efficien

Página 2

10Agilent 4294A precision impedance analyzerAccessories included:• 100  load resistor for four-termi-nal-pair extension• Sample program disk• Power

Página 3

11Fixtures for leaded components16047E (DC to 110 MHz)For leaded components. This fixture features the capability to clamp the leads between the elect

Página 4 - Equivalent circuit analysis

Material test fixtures16451BA dielectric material test fixture, with parallel plate electrodes.16452A (20 Hz to 30 MHz)Dielectric test fixture for liq

Página 5 - Frequency (Hz)

The Agilent Technologies 4294A precision impedance analyzer greatly supports accurate impedance measurement and analysis of a wide variety of electron

Página 6 - Efficient analysis with the

3The Agilent 4294A is a powerful tool for design, qualification, quality control, and production testing of electronic components. Circuit designers a

Página 7 - Sweep, display, and markers

4There is no ideal inductor (L), capacitor (C), or resistor (R). In reality, operat-ing conditions such as signal level and frequency determine the re

Página 8 - Internet

5The Agilent 4294A employs a state-of-the-art auto-balancing-bridge technique in a four-terminal-pair (4TP) measurement configuration. Meticu lous cir

Página 9

6Signal level dependencyThe impedance characteristics of some devices change drastically as a function of the signal level. The Agilent 4294A can swee

Página 10 - Ordering Information

7Three multi-trace modes for comparison evaluationSuperimpose trace (accumulate) modeThis mode is used to observe an inter-mittent event or a change i

Página 11 - Fixtures

8Labs today often require system con-figurations in which test instruments interact with other instruments or handshake with external computers.Agilen

Página 12 - Remove all doubt

9Agilent 42941A impedance probeThe 42941A impedance probe enables in-circuit impedance measurement of electronic circuits or components. Grounded devi