Agilent Technologies 8935 Series Manual do Utilizador Página 310

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 352
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 309
310 Chapter 1
GPIB Command Dictionary
RFGenerator subsystem
:FREQuency <real number>
:FREQuency?
These commands set/query the frequency of the RF generator. The Test
Set must first be in frequency tuning mode. (See CONF:RFD ‘Freq’ on
page 164).
This command utilizes the “Real Number Setting Syntax” on page 299,
but does not use the :STATe command.
Syntax
RFG:FREQ <real number>
RFG:FREQ?
Screen/field equivalent
RFG:FREQ controls the RF Gen Freq field on the RF GENERATOR
screen, when in frequency tuning mode. This field is also displayed on
the spectrum analyzers RF Gen menu.
:MODulation:AOUT <string>
:MODulation:AOUT?
These commands set/query the coupling between the demodulated
audio and the AUDIO OUT port.
Syntax
RFG:MOD:AOUT ‘AC’
‘DC’
RFG:MOD:AOUT?
Screen/field equivalent
RFG:MOD:AOUT controls the Audio Out field on the RF GENERATOR
screen.