Agilent Technologies 8935 Series Manual do Utilizador Página 188

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 352
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 187
188 Chapter 1
GPIB Command Dictionary
CONFigure subsystem
:SPOR11|SPORT11|SB11|SP11:MODem:CONNect:TIMeout
:SPOR11|SPORT11|SB11|SP11:MODem:CONNect:TIMeout?
This command sets/queries the number of seconds to wait before
aborting a connection attempt. This applies to both answer and
originate activities.
Syntax
CONF:SPOR11:MOD:CONN:TIM <integer>
CONF:SPOR11:MOD:CONN:TIM?
Screen/field equivalent
CONF:SPOR11:MOD:CONN:TIM controls the Connection Time-out
field on the MODEM CONFIGURE screen when the Serial Port field
is set to Port 11.
:SPOR11|SPORT11|SB11|SP11:MODem:CONNect:HDELay
:SPOR11|SPORT11|SB11|SP11:MODem:CONNect:HDELay?
This command sets/queries the number of seconds to wait before
attempting an origination. This applies to the delay prior to attempting
a dialback as well as the delay prior to retrying an origination as part of
the retry sequence.
Syntax
CONF:SPOR11:MOD:CONN:HDEL <integer>
CONF:SPOR11:MOD:CONN:HDEL?
Screen/field equivalent
CONF:SPOR11:MOD:CONN:HDEL controls the Hold-off Delay field
on the MODEM CONFIGURE screen when the Serial Port field is set
to Port 11.
Vista de página 187