Chapter 1 127
GPIB Command Dictionary
CDANalyzer subsystem
:PNOFfset <real number>
:PNOFfset?
These commands set/query the PN offset of the system.
This command utilizes the :INCR command of the “Real Number
Setting Syntax” on page 299.
Syntax
CDAN:PNOF <real number> !values from 0.0 to 511.984375
CDAN:PNOF? !returns the value of the PN Offset
Screen/field equivalent
CDAN:PNOF controls the PN Offset field on the CODE DOM screen
when the CDMA standard is set to “IS-95 Only”. This field is displayed
only when the Find PN field on the PN Setup menu is set to Manual.
:POWer:REFerence <string>
:POWer:REFerence?
These commands set/query the power reference for the code domain
analyzer.
Syntax
CDAN:POW:REF ‘0 dB ref’
CDAN:POW:REF?
Screen/field equivalent
CDAN:POW:REF controls the upper subfield of the Pwr Scale field on
the CODE DOM screen when the CDMA standard is set to “IS-95
Only”. This field is displayed on the Marker menu.