PSTatistic Subsystem 9
N1911A/1912A P-Series Power Meters Programming Guide 325
PSTatistic:CCDF:REFerence:MARKer[1]|2[:SET]
This command is used to set the marker on the reference trace. The
markers will be set only if the trace is present and visible. According to
the selections made, the markers will become active on the screen.
Syntax
Example
Reset Condition
On reset, the marker will be set on the next visible trace according to the
sequence of Channel A, Channel B, Reference or Gaussian.
NOTE
This command is only applicable when P-Series sensors are present and the following
conditions are met:
Free-run acquisition mode is selected
NORMal or DOUBle measurement speed setting is chosen
Expanded window is enabled (not full CCDF screen window)
:MARK
PST
:CCDF :REF
2
:SET
1
PST:CCDF:REF:MARK1 This command sets marker 1 on the
reference trace.
Vista de página 352