Frequency Sweep Commands 8
U2761A Programmer’s Reference 93
[SOURce:]SWEep:TIME
Syntax
[SOURce:]SWEep:TIME <seconds>
This command sets the number of seconds required to sweep from the
start frequency to the stop frequency.
[SOURce:]SWEep:TIME?
This query returns the sweep time in seconds.
Parameter
Remark
The number of discrete frequency points in the sweep is automatically
calculated by the U2761A and is based on the sweep time you have
selected.
Examples
The following command sets the sweep time to 20 s.
SWE:TIME 20
The following query returns the sweep time.
SWE:TIME?
Typical response:
+2.0000000000000E+01
Item Type Range of values Default value
seconds Numeric 1 ms to 500 s 1 s
SOUR : SWE space
?
seconds:TIME