Vista de página 22
© Agilent Technologies2000–2003 Agilent 3070 / 79000 DUT Power Supply Installation 20
Setting the DUT Power Supply Line Voltage
6642A Line Voltage Settings
The 6642A supply can be set to accept 100, 120, 220 or
240 volts ac input by setting the line voltage select
switches.
1 Turn off power to the supply and disconnect the
power cord from the power source.
2 Remove the four screws that secure the two carrying
straps and outer cover.
3 Slightly spread the bottom rear of the cover and pull
it back to disengage it from the front panel.
4 Slide the dust cover back far enough to expose the
select switches (see Figure 6).
Figure 6 6642 line voltage selection
5 Move the line voltage select switches to the positions
corresponding to the desired line voltage.
6 Replace the top cover and secure the carrying straps.
7 Change the line fuse (on the rear panel) to the proper
value for the new line voltage (see Tab le 6 on
page 21).
AC line voltage
switch settings
6642pow.wpg
Vista de página 22