Agilent-technologies N2620A Manual do Utilizador Página 229

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 279
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 228
Network Performance Analyzer Reference 8
N2620A User’s Guide 211
The following measurements are taken during the test.
Name Lookup The request or response time for converting a
name into an address.
PING Response The time taken to perform an ICMP Echo test
on the server.
Connect Time/Mount Time The time taken to connect to the NT
file server or to mount the NFS server.
Write Rate The write operation rate, in bytes/s.
Read Rate The read operation rate, in bytes/s.
Delete Time The time taken to delete the file.
Disconnect Time The time taken to disconnect from the file
server.