User’s and Service Guide
Agilent Technologies 85032B/E
50
Type-N Calibration Kits
Agilent Part Number: 85032-90020
Printed in USA
Print Date: July 2002
Supersedes: June 2000
© Copyright 1993, 2000, 2002 Agilent Technologies, Inc. All rights reserved.
Vista de página 0
1 2 3 4 5 6 ... 54 55

Resumo do Conteúdo

Página 1 - User’s and Service Guide

User’s and Service GuideAgilent Technologies 85032B/E 50Ω Type-N Calibration KitsAgilent Part Number: 85032-90020Printed in USA Print Date: July 2002S

Página 2 - Assistance

1-6 85032B/E General InformationClarifying the Sex of a ConnectorClarifying the Sex of a ConnectorIn this manual, the sex of calibration devices and a

Página 3 - Contents

85032B/E 2-12 Specifications

Página 4

2-2 85032B/E SpecificationsEnvironmental RequirementsEnvironmental Requirements Temperature—What to Watch Out ForChanges in temperature can affect ele

Página 5 - 1 General Information

85032B/E 2-3SpecificationsMechanical CharacteristicsMechanical CharacteristicsMechanical characteristics such as center conductor protrusion and pin d

Página 6 - Calibration Kit Overview

2-4 85032B/E SpecificationsMechanical CharacteristicsNOTE The gages for measuring type-N connectors compensate for the designed offset of 5.26 mm (0.2

Página 7 - Calibration Definitions

85032B/E 2-5SpecificationsElectrical SpecificationsElectrical SpecificationsThe electrical specifications in Table 2-3 apply to the devices in your ca

Página 8 - Incoming Inspection

2-6 85032B/E SpecificationsElectrical Specifications

Página 9

85032B/E 3-13 Use, Maintenance, and Care of the Devices

Página 10 - Preventive Maintenance

3-2 85032B/E Use, Maintenance, and Care of the DevicesElectrostatic DischargeElectrostatic DischargeProtection against ESD (electrostatic discharge) i

Página 11 - 2 Specifications

85032B/E 3-3Use, Maintenance, and Care of the DevicesVisual InspectionVisual InspectionVisual inspection and, if necessary, cleaning should be done ev

Página 12 - Environmental Requirements

ii 85032B/E Documentation WarrantyTHE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED "AS IS," AND IS SUBJECT TO BEING CHANGED, WITHOUT NOT

Página 13 - Mechanical Characteristics

3-4 85032B/E Use, Maintenance, and Care of the DevicesCleaning ConnectorsInspect Female ConnectorsPay special attention to the contact fingers in the

Página 14 - Specifications

85032B/E 3-5Use, Maintenance, and Care of the DevicesCleaning ConnectorsUse a lint-free swab or cleaning cloth moistened with isopropyl alcohol to rem

Página 15 - Electrical Specifications

3-6 85032B/E Use, Maintenance, and Care of the DevicesGaging ConnectorsGaging ConnectorsThe gages available from Agilent Technologies are intended for

Página 16 - 2-6 85032B/E

85032B/E 3-7Use, Maintenance, and Care of the DevicesGaging ConnectorsWhen to Gage ConnectorsGage a connector at the following times:• Prior to using

Página 17 - 85032B/E 3-1

3-8 85032B/E Use, Maintenance, and Care of the DevicesGaging ConnectorsGaging ProceduresGaging Male Type-N ConnectorsNOTE Always hold a connector gage

Página 18 - Electrostatic Discharge

85032B/E 3-9Use, Maintenance, and Care of the DevicesGaging ConnectorsFigure 3-3 Gaging Male Type-N Connectors

Página 19 - Visual Inspection

3-10 85032B/E Use, Maintenance, and Care of the DevicesGaging ConnectorsGaging Female Type-N ConnectorsNOTE Always hold a connector gage by the gage b

Página 20 - Cleaning Connectors

85032B/E 3-11Use, Maintenance, and Care of the DevicesGaging ConnectorsFigure 3-4 Gaging Female Type-N Connectors

Página 21 - 85032B/E 3-5

3-12 85032B/E Use, Maintenance, and Care of the DevicesConnectionsConnectionsGood connections require a skilled operator. The most common cause of mea

Página 22 - Gaging Connectors

85032B/E 3-13Use, Maintenance, and Care of the DevicesConnectionsUsing a torque wrench guarantees that the connection is not too tight, preventing pos

Página 23 - Reading the Connector Gage

Contents 85032B/E iii1. General InformationCalibration Kit Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 24 - Gaging Procedures

3-14 85032B/E Use, Maintenance, and Care of the DevicesConnections5. Apply downward force perpendicular to the wrench handle. See Figure 3-6. This app

Página 25 - 85032B/E 3-9

85032B/E 3-15Use, Maintenance, and Care of the DevicesHandling and StorageHow to Separate a ConnectionTo avoid lateral (bending) force on the connecto

Página 26 - 3-10 85032B/E

3-16 85032B/E Use, Maintenance, and Care of the DevicesHandling and Storage

Página 27 - 85032B/E 3-11

85032B/E 4-14 Performance Verification

Página 28 - Connections

4-2 85032B/E Performance VerificationIntroductionIntroductionThe performance of your calibration kit can only be verified by returning the kit to Agil

Página 29 - 85032B/E 3-13

85032B/E 4-3Performance VerificationRecertificationRecertificationThe following will be provided with a recertified kit:• a new calibration sticker af

Página 30 - 3-14 85032B/E

4-4 85032B/E Performance VerificationRecertification

Página 31 - Handling and Storage

85032B/E 5-15 Troubleshooting

Página 32 - 3-16 85032B/E

5-2 85032B/E TroubleshootingTroubleshooting ProcessTroubleshooting ProcessIf you suspect a bad calibration, or if your network analyzer does not pass

Página 33 - 4 Performance Verification

85032B/E 5-3TroubleshootingReturning a Kit or Device to AgilentReturning a Kit or Device to Agilent If your kit or device requires service, contact th

Página 34 - Introduction

iv 85032B/EContents4. Performance VerificationIntroduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 35 - Recertification

5-4 85032B/E TroubleshootingReturning a Kit or Device to Agilent

Página 36 - Performance Verification

85032B/E 6-16 Replaceable Parts

Página 37 - 5 Troubleshooting

6-2 85032B/E Replaceable PartsIntroductionIntroductionTable 6-1 lists the replacement part numbers for items included in the 85032B calibration kit an

Página 38 - Troubleshooting Process

85032B/E 6-3Replaceable PartsIntroductionFigure 6-1 Replaceable Parts for the 85032B Calibration Kit

Página 39 - Troubleshooting

6-4 85032B/E Replaceable PartsIntroductionFigure 6-2 Replaceable Parts for the 85032E Calibration KitTable 6-2 Replaceable Parts for the 85032E Calibr

Página 40 - 5-4 85032B/E

85032B/E 6-5Replaceable PartsIntroductionTable 6-3 Replaceable Parts—Items Not Included in the Calibration KitItem No. Description Qty Agilent Par

Página 41 - 6 Replaceable Parts

6-6 85032B/E Replaceable PartsIntroduction

Página 42

85032B/E A-1A Standard Definitions

Página 43 - Replaceable Parts

A-2 85032B/E Standard DefinitionsStandard Class AssignmentsStandard Class AssignmentsClass assignment organizes calibration standards into a format co

Página 44 - 6-4 85032B/E

85032B/E A-3Standard DefinitionsStandard Class AssignmentsBlank FormThe standard class assignments listed in Table A-1 may be changed to meet your spe

Página 45 - 85032B/E 6-5

85032B/E 1-11 General Information

Página 46 - 6-6 85032B/E

A-4 85032B/E Standard DefinitionsNominal Standard DefinitionsNominal Standard DefinitionsStandard definitions provide the constants needed to mathemat

Página 47 - A Standard Definitions

85032B/E A-5Standard DefinitionsNominal Standard DefinitionsTable A-3 Standard Definitions System Z0a = 50 Ωa. Ensure system impedance (Z0) of network

Página 48 - Standard Class Assignments

A-6 85032B/E Standard DefinitionsNominal Standard DefinitionsBlank FormThe standard definitions listed in Table A-3 may be changed to meet your specif

Página 49 - Blank Form

Index85032B/E Index-1Aadapters, 1-3part numbers, 6-5Agilent Technologies, contacting, 5-3alcoholisopropylas cleaning solvent, 3-4altitude, 2-2Bblank

Página 50 - Nominal Standard Definitions

Index-2 85032B/E Indexconnecting, 3-14disconnecting, 3-14frequencyspecifications, 2-5frequency range, 2-5, 4-3Ggageconnectordial, 3-7handling, 3-8, 3-

Página 51 - Standard Definitions

Index85032B/E Index-3temperature, 2-2supplemental characteristics, 2-3supplemental electrical characteristics, 2-5suppliescleaning, 1-3system impedan

Página 52

1-2 85032B/E General InformationCalibration Kit OverviewCalibration Kit OverviewThe Agilent 85032B and 85032E type-N calibration kits are used to cali

Página 53 - 85032B/E Index-1

85032B/E 1-3General InformationCalibration Kit OverviewAdaptersLike the other devices in the kit, the adapters are built to very tight tolerances to p

Página 54 - Index-2 85032B/E

1-4 85032B/E General InformationIncoming InspectionIncoming InspectionVerify that the shipment is complete by referring to Figure 6-1 or Figure 6-2.Ch

Página 55 - 85032B/E Index-3

85032B/E 1-5General InformationRecording the Device Serial NumbersRecording the Device Serial NumbersIn addition to the kit serial number, the devices