Table 56
Name Description under
:ZSUBstitut[:ZRUN][?] “SENSe[1]:PATTern:ZSUBstitut[:ZRUN]
[?]” on page 252
Subnodes
:UPATtern<n> “SENSe[1]:PATTern:UPATtern
Subnode” on page 253
:UFILe “SENSe[1]:PATTern:UFILe Subnode” on
page 259
SENSe[1]:PATTern:FORMat[:DATA][?]
IAgilentN490xEDPatternfileGetData
SENSe[1]:PATTern:FORMat[:DATA] PACKed, <NR1>
SENSe[1]:PATTern:FORMat[:DATA]?
<PACKed>: Permits the packing of bits within a byte to be set.
<NR1>: Can be 1, 4, or 8.
1 | 4 | 8
The command controls the format of data transfer for
the :PATTern:UPATtern<n>:DATA, :PATTern:UPATtern<n>:IDATa, :PATTern:UFIL
e:DATA and :PATTern:UFILe:IDATa commands. The following values are possible:
1
The data is sent as a string of 1s and 0s.
4
The data is sent as a string of hex characters.
8
The data is sent as a string of full ASCII characters.
The query returns the current value of the data pack.
See “Working with User Patterns in SCPI” on page 63 for descriptions on how to
use the data packing.