33-5
RF Generator Subsystem
MODulation:DCAM:DVALue
MODulation:DCAM:DVALue
Description Sets/queries the DC AM DAC VALue for RFG:MODE:DCAM selected as TCH LOWER,
‘BCCHLOWER’ or ‘BOTHLOWER’.
Syntax RFGenerator:MODulation:DCAM:DVALue?
RFGenerator:MODualtion:DCAM:DVALue <integer> | [:INUM]
Options Refer to Appendix A.
MODulation:GMSK
Description Selects/queries the state of GMSK modulation.
Syntax RFGenerator:MODulation:GMSK?
RFGenerator:MODualtion:GMSK <string>
Options ’EXT’ | ’OFF’
Where;
EXT means GMSK comes from external data and clock inputs.
OFF means the RF output is an unmodulated carrier.
MODulation:PULSe
Description Selects/queries the state of PULSe modulation.
Syntax RFGenerator:MODulation:PULSe?
RFGenerator:MODualtion:PULSe <string>
Options ’EXT’ | ’HOP TRIG’ | ’OFF’
Where;
EXT means PULSe modulation comes from an external (TTL) input.
HOP TRIG means the RF output automatically pulses off (for a little while) during
switching transients when an RF Generator hop trigger occurs.
OFF means no PULSe modulation.