Agilent
E6474A Wireless Network
Optimization Platform
Configuration Guide
The Agilent E6474A wireless network optimization platform is
used to obtain RF coverage measurements and service perform-
ance measurements for wireless communications networks
that use cdmaOne, cdma2000, GSM, UMTS, TDMA, iDEN and
GPRS technologies. The system software runs on a PC that inter-
faces with an Agilent digital RF receiver and/or scanner. The
system software also simultaneously interfaces with a cdmaOne,
cdma2000, GSM, GPRS, GAIT, UMTS, TDMA and/or iDEN
phone. The system can be configured to include receivers or
scanners and/or phones from one or various technologies. The
system can control up to four phones simultaneously (two
phones for simultaneous trace/data measurements).
The Agilent network optimization drive test solution can be
ordered through part numbers E6473A, E6473B, E6474A,
E6450C, E6451C, E6452C, E6453C, E6454C, E6455C, E6456C,
E6457C, E6478C, E7456C, E7462A through E7469A, 86154A, and
86156A. These part numbers are described in the following con-
figuration guide.
The Agilent E6474A is available in the
following configuration:
• Phone-based systems
• Receiver/scanner-based systems
• Combination phone and receiver/scanner-based systems
Single technology or multiple technology configurations
can be made with any of the above combinations.
The purpose of this configuration guide is to assist you in
ordering the correct system configuration for your application.
This document is divided into several parts:
Part 1: Basic description of product configuration
Part 2: Software options
Part 3: Receiver and scanner hardware options
Part 4: Accessories
Minimum PC specifications:
Processor / memory requirements:
Single phone
• Windows® 98, 2000 and ME
• Minimum: 330MHz PIII, 128MB RAM
• Recommended: 500MHz PIII, 256MB RAM
Multiple phone
• Windows® 98, 2000 and ME
• Minimum: 450MHz PIII, 128MB
RAM
• Recommended: 600MHz PIII, 256MB RAM
Common requirements:
• RS-232 DB9 serial port
• Parallel port
• Two PCMCIA slots or a USB connection (for multiple phone operation)
• 90 MB disk space for software installation
• 200 MB disk space recommended for data
• CD-ROM drive recommended
• 1024 x 768 display resolution minimum
Part 5: Upgrading existing systems
Part 6: Ordering examples
Part 7: Support Options
Part 1: Basic description of product configuration
The system is made up of software, receiver and scanner
hardware, and accessories. To order a system you:
1. Select your technology
E6474A-1x0 -- CDMA
E6474A-1x1 -- cdma2000
E6474A-2x0 -- GSM
E6474A-4x0 -- iDEN
E6474A-5x0 -- TDMA
E6474A-6x0 -- GPRS
2. Choose your desired level of functionality
E6474A-x0x -- Phone
E6474A-x1x -- Receiver
E6474A-x2x -- Combination system
3. Select data test functionality if needed
E6474A -700 -- Client data measurement
E6474A-710 -- Server data measurement software
4. Select any platform level software add-on needed
E6474A-010 -- Multiple phones
E6474A-020 and E6474A-030 -- Mapping options
5. Select desired scanner or receiver
E746xA -- Scanners
E645xC, E7456C -- Receivers
6. Select desired phone interface cable
E6473B-8xx
7. Select desired Agilent high speed direct hub and hub kit
E6473B-015 and kit E6473B-02x
8. Select desired GPS options
E6473B-03x
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1 - Optimization Platform

Agilent E6474A Wireless Network Optimization PlatformConfiguration GuideThe Agilent E6474A wireless network optimization platform isused to obtain RF

Página 2 - Technology

10From Figure 3Choose Accessories(Direct Connect Hub and kit)E6473B-015Agilent high speed direct connect hubE6473B-021 In-vehicle Agilent high speed d

Página 3 - Part 2: Software options

11Figure 5. Ordering decision process - GPS and dead reckoning accessories for new systemsFigure 6. Ordering decision process - additional drive test

Página 4 - GAIT/GPRS configuration

12Part 4: AccessoriesIn addition to the E6474A software licenses and either receiveror scanner hardware, Agilent supplies a range of accessory product

Página 5

13Part 4.3: Indoor (portable) measurement accessoriesThe following accessories are provided for indoor and portablewireless measurements: E6473B-330 F

Página 6 - Table 2. Option exceptions

Part 4.4: Phone and phone interface cable system accessoriesThe following accessories describe the phone and phone interface cables for indoor measure

Página 7

Part 5: Upgrading existing systemsThe Agilent E6474A is a scalable system. You can start with oneset of capability and integrate additional capability

Página 8

Part 6: Ordering examplesPart 6.1: CDMA ordering examplesTable 3 lists several typical E6474A system configurations forcdmaOne along with the products

Página 9 - Scanners

17Desired system capabilitycdma2000 receiver-based measurement system for thecellular band. You will provide your own GPS and laptop. cdma2000 receive

Página 10 - Accessories)

18Desired system capabilityGSM phone-based measurement system (single phone).Desire real time mapping. Sagem phone interface cablewith external RF. Yo

Página 11

19Desired system capabilityGPRS phone-based measurement system (single phone).Desire direct connect, real time mapping. You will provideyour own GPS a

Página 12 - Part 4: Accessories

2Each system requires an Agilent digital receiver or scanner, amobile phone, or a combination of a receiver/scanner andphone. The system also requires

Página 13

20Desired system capabilityW-CDMA (UMTS) receiver-based measurement system.Real time mapping desired. You will provide you own laptop.W-CDMA (UMTS) re

Página 14 - Part 4.4: Phone and phone

21Part 6.6: iDEN ordering examplesTable 8 lists several typical E6474A network optimization solution system configurations for iDEN along with the pro

Página 15

22Desired system capabilityTDMA phone-based measurement system (single phone).Desire real time mapping. Cable for Nokia 6160 phone. Youwill provide yo

Página 16 - Part 6: Ordering examples

Part 7: Support OptionsFor the E6474A receiver software licenses and combinationreceiver/phone licenses, the following support options areincluded for

Página 17 - Desired system capability

Additional Agilent literatureBrochuresAccelerate cdma2000 Performance With Agilent’s Wireless Network Solutions Brochure...

Página 18

3Part 2: Software optionsThis part of the document assumes that you are building a newsystem. If you are adding functionality to an existing system,re

Página 19

4Use Table 1 to determine which software option(s) are required for your application. Desired functionality Required software option(s)cdmaOne configu

Página 20

W-CDMA (UMTS) configurationsW-CDMA (UMTS) phone-based drive system measurements (single phone) E6474A-300W-CDMA (UMTS) receiver-based drive system me

Página 21

6Indoor measurement capability E6474A-030 (can be combined with(can be combined with all other software functionality) any or all soft-ware option num

Página 22

From Figure 2Choose Receiver orScanner HardwareE6453CK-CDMA Receiver (1800MHz) with internal GPSE7462A 850MHz CDMAScannerE7463A 1900MHz CDMAScannerE74

Página 23 - Part 7: Support Options

8Part 3: Receiver/scanner hardware optionsThis part of the document assumes that you are building a newsystem. If you are adding functionality to an e

Página 24 - Additional Agilent literature

9ScannersE7457A: TDMA scanner at 850 MHzE7458A: TDMA scanner at 1900 MHzE7459A: TDMA scanner at 850/1900 MHzE7462A: CDMA scanner at 850 MHzE7463A: CDM