26-4
OSCilloscope Subsystem
SCALe:TIME
SCALe:TIME
Description Selects/queries the horizontal sweep time per division.
Syntax OSCilloscope:SCALe:TIME?
OSCilloscope:SCALe:TIME <string>
Options ’200 ms’ | ’100 ms’ | ’50 ms’ | ’20 ms’ |
’10 ms’ | ’5 ms’ | ’2 ms’ | ’1 ms’, |
’500 us’ | ’200 us’ | ’100 us’ | ’50 us’ |
’20 us’ | ’10 us’ | ’5 us’ | ’2 us’ |
’1 us’
SCALe:VERTical:AM
Description Selects/queries the VERTical amplitude per division for AF Analyzer input selections
(AFAN:INP) that have AM units of Percent.
Syntax OSCilloscope:SCALe:VERTical:AM?
OSCilloscope:SCALe:VERTical:AM <string>
Options ’50 %’ | ’20 %’ | ’10 %’ | ’5 %’ |
’2 %’ | ’1 %’ | ’0.5 %’ | ’0.2 %’ |
’0.1 %’ | ’0.05 %’
SCALe:VERTical:FM
Description Selects/queries the VERTical amplitude per division for AF Analyzer input selections
(AFAN:INP) that have FM units of Hertz.
Syntax OSCilloscope:SCALe:VERTical:FM?
OSCilloscope:SCALe:VERTical:FM <string>
Options ’50 kHz’ | ’20 kHz’ | ’10 kHz’ | ’5 kHz’ |
’2 kHz’ | ’1 kHz’ | ’500 Hz’ | ’200 Hz’ |
’100 Hz’ | ’50 Hz’ | ’20 Hz’ | ’10 Hz’