Agilent Technologies N9344C Manual de Serviço Página 170

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 224
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 169
162 Programmer’s Guide
5 Command Reference
Display Threshold State
:CHSCanner:DISPlay:THReshold [:STATe] OFF|ON|0|1
:CHSCanner:DISPlay:THReshold [:STATe]?
This command toggles display threshold state. Then the display
threshold is turned on, only the channels with higher channel power
than the threshold value will be displayed on the screen.
Remark: This parameter is only available for Table (Bar) display mode.
Example: :CHSCanner:DISPlay:THREShold 1
Key access: Shift > Disp > Disp Mode > Threshold
Display Threshold Value
:CHSCanner:DISPlay:THReshold:VALue <value>
:CHSCanner:DISPlay:THReshold:VALue?
This command defines the display threshold value.
Example: :CHSCanner:DISPlay:THReshold:VALue -70
Key access: Shift > Disp > Disp Mode > Threshold
Limit State
:CHSCanner:DISPlay:LIMit[:STATe] OFF|ON|0|1
:CHSCanner:DISPlay:LIMit[:STATe]?
Use this command to turn on/off limit state in channel scanner mode.
Example: :CHSCanner:DISPlay:LIMit ON
Key access: Shift > Limit > Limit
Limit Value
:CHSCanner:DISPlay:LIMit:VALue <value>
:CHSCanner:DISPlay:LIMit:VALue?
This command specify the limit value in channel scanner mode.
Example: :CHSCanner:DISPlay:LIMit:VALue -20
Key access: Shift > Limit > Limit
Vista de página 169
1 2 ... 165 166 167 168 169 170 171 172 173 174 175 ... 223 224

Comentários a estes Manuais

Sem comentários