496 Agilent InfiniiVision 3000 X-Series Oscilloscopes Programmer's Guide
24 :SBUS<n> Commands
:SBUS<n>:IIC[:SOURce]:CLOCk
(see page 860)
Command Syntax
:SBUS<n>:IIC:[SOURce:]CLOCk <source>
<source> ::= {CHANnel<n> | EXTernal} for the DSO models
<source> ::= {CHANnel<n> | DIGital<d>} for the MSO models
<n> ::= 1 to (# analog channels) in NR1 format
<d> ::= 0 to (# digital channels - 1) in NR1 format
The :SBUS<n>:IIC:[SOURce:]CLOCk command sets the source for the IIC
serial clock (SCL).
Query Syntax
:SBUS<n>:IIC:[SOURce:]CLOCk?
The :SBUS<n>:IIC:[SOURce:]CLOCk? query returns the current source for
the IIC serial clock.
Return Format
<source><NL>
See Also "Introduction to :TRIGger Commands" on page 641
":SBUS<n>:IIC[:SOURce]:DATA" on page 497