Agilent Technologies 8000 Series Especificações

Consulte online ou descarregue Especificações para Medição, teste e controlo Agilent Technologies 8000 Series. Agilent Technologies 8000 Series Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Service Guide

Service GuidePublication Number D8064-97006September 2007 Copyright Agilent Technologies 2005-2007All Rights Reserved.8000 Series Infiniium Oscillosc

Página 2

10General InformationThis chapter of the Agilent Technologies Infiniium Oscilloscope Service Guide gives you general information about the oscilloscop

Página 3

Chapter 6: Replacing Assemblies To remove and replace the bottom sleeve1008Remove the two T20 handle screws to remov

Página 4

Chapter 6: Replacing AssembliesTo disconnect and connect Mylar flex cables101To disconnect and connect Mylar

Página 5 - In This Book

Chapter 6: Replacing Assemblies To remove and replace the CD-ROM drive102To remove and replace the CD-ROM driveUse t

Página 6

Chapter 6: Replacing AssembliesTo remove and replace the CD-ROM drive1036Using a Torx T6 driver, remove the

Página 7 - Contents

Chapter 6: Replacing Assemblies To remove and replace the AutoProbe assembly104To remove and replace the AutoProbe a

Página 8 - 8 Theory of Operation

Chapter 6: Replacing AssembliesTo remove and replace the AutoProbe assembly105Figure 6-9Access HoleCAUTION A

Página 9

Chapter 6: Replacing Assemblies To remove and replace the internal digital input cable (MSO models only)106To remove

Página 10 - General Information

Chapter 6: Replacing AssembliesTo remove and replace the backlight inverter board107To remove and replace th

Página 11

Chapter 6: Replacing Assemblies To remove and replace the front panel assembly108To remove and replace the front pan

Página 12

Chapter 6: Replacing AssembliesTo remove and replace the front panel assembly1095Disconnect the backlight pr

Página 13 - Accessories supplied

Chapter 1: General InformationInstruments covered by this service guide11Instruments covered by this service

Página 14 - Accessories available

Chapter 6: Replacing Assemblies To remove and replace the front panel assembly1107Disconnect the flat-panel display

Página 15 - Options available

Chapter 6: Replacing AssembliesTo remove and replace the front panel assembly1119Remove the four Torx T15 sc

Página 16 - ± 5°C from the temperature

Chapter 6: Replacing Assemblies To remove and replace the front panel assembly112Figure 6-17Connecting the USB cable

Página 17 - Measurement Category

Chapter 6: Replacing AssembliesTo remove and replace the keyboard, touch screen, and flat-panel display asse

Página 18 - Oscilloscope Dimensions

Chapter 6: Replacing Assemblies To remove and replace the keyboard, touch screen, and flat-panel display assemblies1

Página 19 - Preparing for Use

Chapter 6: Replacing AssembliesTo remove and replace the keyboard, touch screen, and flat-panel display asse

Página 20 - Setting Up the Oscilloscope

Chapter 6: Replacing Assemblies To remove and replace the acquisition board assembly116To remove and replace the acq

Página 21 - Figure 2-1

Chapter 6: Replacing AssembliesTo remove and replace the PCI bridge board117To remove and replace the PCI br

Página 22 - To connect power

Chapter 6: Replacing Assemblies To remove and replace the PCI bridge board1184Remove the Torx T10 screw that secures

Página 23

Chapter 6: Replacing AssembliesTo remove and replace the display board119To remove and replace the display b

Página 24

Chapter 1: General Information To determine whether the oscilloscope is under warranty12To determine whether the osc

Página 25 - Attaching the Probe Connector

Chapter 6: Replacing Assemblies To remove and replace the hard disk drive120To remove and replace the hard disk driv

Página 26 - Probing the Circuit

Chapter 6: Replacing AssembliesTo remove and replace the hard disk drive121Figure 6-27Removing the hard disk

Página 27

Chapter 6: Replacing Assemblies To remove and replace the motherboard122To remove and replace the motherboardUse thi

Página 28 - To connect the digital probe

Chapter 6: Replacing AssembliesTo remove and replace the motherboard1239To replace the motherboard assembly,

Página 29 - Digital probe lead set

Chapter 6: Replacing Assemblies To replace the Intel motherboard with the ADLINK motherboard124To replace the Intel

Página 30 - 40-pin Connector Pinout

Chapter 6: Replacing AssembliesTo replace the Intel motherboard with the ADLINK motherboard12511Remove the A

Página 31 - Figure 2-14

Chapter 6: Replacing Assemblies To replace the Intel motherboard with the ADLINK motherboard12615Turn the front pane

Página 32 - To turn off the oscilloscope

Chapter 6: Replacing AssembliesTo replace the Intel motherboard with the ADLINK motherboard12718Pull back th

Página 33 - Probe Compensation

Chapter 6: Replacing Assemblies To replace the Intel motherboard with the ADLINK motherboard12825Install the 5 short

Página 34

Chapter 6: Replacing AssembliesTo replace the Intel motherboard with the ADLINK motherboard12928Re-install t

Página 35 - To clean the oscilloscope

Chapter 1: General InformationAccessories supplied13Accessories suppliedStandard accessories supplied• Mouse

Página 36

Chapter 6: Replacing Assemblies To replace the Intel motherboard with the ADLINK motherboard130b Connect the two USB

Página 37 - Testing Performance

Chapter 6: Replacing AssembliesTo remove and replace the power supply131To remove and replace the power supp

Página 38

Chapter 6: Replacing Assemblies To remove and replace the power supply1323Disconnect the following cables from the t

Página 39 - Fluke MET/CAL Procedures

Chapter 6: Replacing AssembliesTo remove and replace the power supply133Figure 6-33Removing the power supply

Página 40 - To test the DC calibrator

Chapter 6: Replacing Assemblies To remove and replace the fan controller board134To remove and replace the fan contr

Página 41

Chapter 6: Replacing AssembliesTo remove and replace a fan135To remove and replace a fanUse this procedure t

Página 42 - To test input resistance

Chapter 6: Replacing Assemblies To remove and replace the probe power and control assembly136To remove and replace t

Página 43 - Connect the equipment

7Ordering Replaceable Parts 138Listed Parts 138Unlisted Parts 138Direct Mail Order System 138Exchange Assemblies 138Power Cords 139Explode

Página 44

138Replaceable Parts This chapter of the Agilent Technologies Infiniium Oscilloscope Service Guide includes information for ordering parts. Service

Página 45 - (Supply) Minimum Maximum

Chapter 7: Replaceable PartsPower Cords139Power CordsThis oscilloscope is equipped with a three-wire power c

Página 46 - Set the offset from the

Chapter 1: General Information Accessories available14Accessories availableThe following accessories are available f

Página 47 - To test bandwidth

Chapter 7: Replaceable Parts Exploded Views140Exploded ViewsFront Frame and Front Panel

Página 48

Chapter 7: Replaceable PartsExploded Views141Fan and Acquisition Assembly

Página 49 - To verify threshold accuracy

Chapter 7: Replaceable Parts Exploded Views142Power Supply and PC Motherboard Without Option 017

Página 50 - Connections

Chapter 7: Replaceable PartsExploded Views143Power Supply and PC Motherboard With Option 017

Página 51

Chapter 7: Replaceable Parts Exploded Views144Sleeve and Accessory Pouch

Página 52

Chapter 7: Replaceable PartsReplaceable Parts List145Replaceable Parts ListThe following table is a list of

Página 53

Chapter 7: Replaceable Parts Replaceable Parts List146W18 8120-1703 1 CABLE-POWER (Option 900-UK)W18 8120-0696 1 CAB

Página 54

Chapter 7: Replaceable PartsReplaceable Parts List147H6 0515-0372 22 SCREW-MACH; M3 X 0.5 8MM-LG ; T10; WAS

Página 55 - High-to-Low Transitions

Chapter 7: Replaceable Parts Replaceable Parts List148W4 D8064-61601 1 POWER HARNESS CABLEW5 54810-61617 1 POWER INP

Página 56 - Threshold Voltage Setting V2

8Block-Level Theory 151Power Supply Assembly 152FPD Monitor Assembly 152Acquisition System 152Front Panel 152Disk Drives 152Attenuators

Página 57 - Low-to-High Transitions

Chapter 1: General InformationOptions available15Options availableThe following options are available for th

Página 58

Chapter 8: Theory of Operation 150Figure 8-1 Oscilloscope Block Diagram

Página 59 - To test time scale accuracy

151Theory of OperationThis Service Guide supports troubleshooting the Agilent Technologies oscilloscopes to assembly level. Theory of operation is inc

Página 60 - Frequency Reference

Chapter 8: Theory of Operation Block-Level Theory152Power Supply AssemblyThe AC input to the power supply is 100–240

Página 61

Chapter 8: Theory of OperationBlock-Level Theory153MotherboardThe motherboard provides all system control an

Página 62

Chapter 8: Theory of Operation Block-Level Theory154Figure 8-2 Acquisition Block DiagramAttenuatorRattlerPreAmp &

Página 63

Chapter 8: Theory of OperationAttenuator Theory155Attenuator TheoryThe channel input signals are conditioned

Página 64 - Agilent Technologies

Chapter 8: Theory of Operation Acquisition Theory156Time Base The time base provides the sample clocks and timing ne

Página 65 - Range Supply Limits

Chapter 8: Theory of OperationAcquisition Theory157Interface and GPIB Board (A21)The Interface Board (A21) h

Página 67 - Calibrating and Adjusting

159Aaccessories, 13, 14supplied, 20, 21airflow requirements, 23application software, 34Autoscale, 33Bback panel connections, 24BNC connectors, 25, 2

Página 68

Chapter 1: General Information Specifications & characteristics16Specifications & characteristics For comple

Página 70

Safety NoticesThis apparatus has been designed and tested in accor-dance with IEC Publication EN 61010-1:2001, Safety Require-ments for Measuring Appa

Página 71 - Troubleshooting

Notices© Agilent Technologies, Inc. 2005-2007No part of this manual may be reproduced in any form or by any means (including electronic storage and re

Página 72

Chapter 1: General InformationEnvironmental Conditions17Environmental Conditions Overvoltage CategoryThis pr

Página 73 - Default Setup

Chapter 1: General Information Oscilloscope Dimensions18Oscilloscope DimensionsFigure 1-18000 Series Oscilloscope Di

Página 74

2To inspect package contents 20To connect power 22To connect the mouse, keyboard, LAN, printer, and GPIB cable 24To connect optional InfiniiMax

Página 75 - 54830F01a

2The Agilent Infiniium Oscilloscope Model 8000 Series at a GlanceEase of use with high performanceThe Agilent Technologies Infiniium oscilloscopes com

Página 76 - Primary Trouble Isolation

20Setting Up the OscilloscopeThis chapter shows you how to set up your Infiniium oscilloscope, connect power and accessories, and verify general opera

Página 77 - Run oscilloscope self-tests

Chapter 2: Preparing for UseTo inspect package contents21Figure 2-1Package Contents for the 8000 Series Infi

Página 78 - Performance” on page 37

Chapter 2: Preparing for Use To connect power22To connect power1 Position the oscilloscope where it will have suffic

Página 79 - No Display Trouble Isolation

Chapter 2: Preparing for UseTo connect power23Figure 2-3Infiniium Oscilloscope Power Cord ConnectionThe osci

Página 80

Chapter 2: Preparing for Use To connect the mouse, keyboard, LAN, printer, and GPIB cable24To connect the mouse, key

Página 81 - Input Pin # 7 65432 1

Chapter 2: Preparing for UseTo connect the standard 10073C probes25To connect the standard 10073C probes1 At

Página 82

Chapter 2: Preparing for Use To connect optional InfiniiMax oscilloscope probes26To connect optional InfiniiMax osci

Página 83

Chapter 2: Preparing for UseTo connect optional InfiniiMax oscilloscope probes273To disconnect the probe, pu

Página 84 - Replace the power supply

Chapter 2: Preparing for Use To connect the digital probe28To connect the digital probeThe Agilent Mixed-Signal Osci

Página 85 - To check probe power outputs

Chapter 2: Preparing for UseDigital probe lead set29Digital probe lead setThe probe lead set has 16 digital

Página 86 - To Check the keyboard

38000 Series Oscilloscope Front PanelPowerAcquisition and General ControlsHorizontal ControlsMarker and Quick Measurement ControlsVertical ControlsVer

Página 87 - To check the LEDs

Chapter 2: Preparing for Use Digital probe lead set30Figure 2-12Equivalent Load including oscilloscopeDirect connect

Página 88 - Intel D915GUX Motherboard

Chapter 2: Preparing for UseTo tilt the oscilloscope upward for easier viewing31To tilt the oscilloscope upw

Página 89 - 5 and 7

Chapter 2: Preparing for Use To turn on the oscilloscope32To turn on the oscilloscope1 Depress the power switch in t

Página 90

Chapter 2: Preparing for UseTo verify basic oscilloscope operation33To verify basic oscilloscope operation1

Página 91 - To setup the BIOS

Chapter 2: Preparing for Use Installing application programs on Infiniium34Installing application programs on Infini

Página 92

Chapter 2: Preparing for UseTo clean the oscilloscope35To clean the oscilloscope• Clean the oscilloscope wit

Página 93 - Figure 5-12

Chapter 2: Preparing for Use To clean the oscilloscope36

Página 94 - Software Revisions

3Testing Interval 38Equipment Required 38Self-Test Verification 38Test Record 38Operating Hints 38Specifications 39Performance Test Proced

Página 95 - Replacing Assemblies

38Testing PerformanceThe procedures in this section test measurement performance using performance specifications.Testing IntervalThe performance test

Página 96

Chapter 3: Testing Performance39of the testing.Clear DisplayWhen using many averages, it often takes awhile

Página 97

48000 Series Oscilloscope Back PanelNote: Your instrument’s back panel configuration may differ from this diagram. LAN PortGPIB InterfaceMouse and Key

Página 98

Chapter 3: Testing Performance To test the DC calibrator40To test the DC calibratorThe Aux Out BNC on the back panel

Página 99 - Bottom sleeve fasteners

Chapter 3: Testing PerformanceTo test the DC calibrator415Set the DC output voltage to +2.400 V using the Le

Página 100 - Removing bottom sleeve

Chapter 3: Testing Performance To test input resistance42To test input resistanceThis test checks the input resistan

Página 101 - Connecting Mylar flex sables

Chapter 3: Testing PerformanceTo test single cursor voltage measurement accuracy with offset43To test single

Página 102

Chapter 3: Testing Performance To test single cursor voltage measurement accuracy with offset44Figure 3-3Voltage Mea

Página 103

Chapter 3: Testing PerformanceTo test single cursor voltage measurement accuracy with offset458Select Vavg f

Página 104 - Disconnecting W8

Chapter 3: Testing Performance To test single cursor voltage measurement accuracy with offset46Figure 3-6Vertical Sc

Página 105 - Access Hole

Chapter 3: Testing PerformanceTo test bandwidth47To test bandwidthThis test checks the bandwidth of the osci

Página 106

Chapter 3: Testing Performance To test bandwidth4810Change the signal generator output frequency to 600 MHz for the

Página 107

Chapter 3: Testing PerformanceTo verify threshold accuracy49To verify threshold accuracyThis test verifies t

Página 108 - Removing the BNC nuts

5In This BookThis book provides the service documentation for the Agilent Technologies 8000-Series oscilloscopes. It is divided into eight chapters.Ch

Página 109

Chapter 3: Testing Performance To verify threshold accuracy50Connections1 Construct a fixture using the BNC breakout

Página 110

Chapter 3: Testing PerformanceTo verify threshold accuracy513Power on the instruments and wait at least 30 m

Página 111

Chapter 3: Testing Performance To verify threshold accuracy52f Select Measure from the menu bar and then select Mark

Página 112 - Figure 6-17

Chapter 3: Testing PerformanceTo verify threshold accuracy53“Oscilloscope Threshold Voltage Setting” in Tabl

Página 113

Chapter 3: Testing Performance To verify threshold accuracy545 Set up the Acquisition system as follows:a Select Set

Página 114

Chapter 3: Testing PerformanceTo verify threshold accuracy55High-to-Low Transitions1 Set the DC Signal Sourc

Página 115

Chapter 3: Testing Performance To verify threshold accuracy56• If at least one bit is still logic 1, reset the input

Página 116

Chapter 3: Testing PerformanceTo verify threshold accuracy57Low-to-High Transitions1 Set the DC Signal Sourc

Página 117

Chapter 3: Testing Performance To verify threshold accuracy58least one bit was logic 0 as V2 in Table 4. Table 4: Th

Página 118

Chapter 3: Testing PerformanceTo test time scale accuracy59To test time scale accuracyDescriptionTSA (time s

Página 120

Chapter 3: Testing Performance To test time scale accuracy60ConnectionsProcedure1Configure the sine wave source to o

Página 121

Chapter 3: Testing PerformanceTo test delta time measurement accuracy61To test delta time measurement accura

Página 122

Chapter 3: Testing Performance To test delta time measurement accuracy62Equipment RequiredConnectionsEquipment Criti

Página 123

Chapter 3: Testing PerformanceTo test delta time measurement accuracy63Procedure1Configure the sine wave sou

Página 124

Chapter 3: Testing Performance Performance Test Record64Performance Test RecordAgilent TechnologiesAgilent 8000 Seri

Página 125

Chapter 3: Testing PerformancePerformance Test Record65Single Cursor Voltage Measurement Accuracy with Offse

Página 126

Chapter 3: Testing Performance Performance Test Record66

Página 127

4Self Calibration Interval 68Calibration Procedures 68To run the self calibration 69Calibrating and Adjusting

Página 128

68Calibrating and AdjustingThis chapter provides the self-calibration procedure for the Agilent Technologies 8000 Series oscilloscope.Hardware Adjustm

Página 129

Chapter 4: Calibrating and AdjustingTo run the self calibration69To run the self calibrationEquipment Requir

Página 130

Contents71 General InformationInstruments covered by this service guide 11To determine whether the oscilloscope is under warranty 12Accessories supp

Página 131 - Acquisition board cables

Chapter 4: Calibrating and Adjusting To run the self calibration70Figure 4-1 Calibration Dialog 3Connect an adapte

Página 132 - Figure 6-32

5Safety 72Tools Required 72ESD Precautions 72Keystroke Conventions 72Default Setup 73To install the fan safety shield 73To troubleshoot th

Página 133

72TroubleshootingThis section provides troubleshooting information for the Agilent Technologies 8000 Series oscilloscope. The service strategy of this

Página 134 - Lift board out of chassis

Chapter 5: TroubleshootingTo install the fan safety shield73Default SetupA Default Setup is provided to ensu

Página 135 - To remove and replace a fan

Chapter 5: Troubleshooting To troubleshoot the oscilloscope74To troubleshoot the oscilloscopeThe troubleshooting pro

Página 136 - T10 Torx Screws

Chapter 5: TroubleshootingTo troubleshoot the oscilloscope75Primary Trouble Isolation FlowchartPrimary Troub

Página 137 - Replaceable Parts

Chapter 5: Troubleshooting Primary Trouble Isolation76Primary Trouble IsolationThe actions in the Primary Trouble Is

Página 138

Chapter 5: TroubleshootingPrimary Trouble Isolation77CRun oscilloscope self-tests.1 Select Self Test from th

Página 139 - Power Cords

Chapter 5: Troubleshooting Primary Trouble Isolation78Use the following procedure to test the front-panel LED (light

Página 140 - Exploded Views

Chapter 5: TroubleshootingNo Display Trouble Isolation79No Display Trouble IsolationThis trouble isolation p

Página 141

Contents8No Display Trouble Isolation 79To check the backlight inverter voltages 81To check the display board video signals 82Power Supply Trouble

Página 142

Chapter 5: Troubleshooting No Display Trouble Isolation80No Display Trouble Isolation FlowchartNo Display TroubleIso

Página 143

Chapter 5: TroubleshootingTo check the backlight inverter voltages81To check the backlight inverter voltages

Página 144

Chapter 5: Troubleshooting To check the display board video signals82To check the display board video signals(Note t

Página 145 - Replaceable Parts List

Chapter 5: TroubleshootingPower Supply Trouble Isolation83Power Supply Trouble IsolationPower Supply Trouble

Página 146

Chapter 5: Troubleshooting Power Supply Trouble Isolation84Figure 5-7Power Supply Voltage Test Locations (A13)Table

Página 147

Chapter 5: TroubleshootingTo check probe power outputs85To check probe power outputsProbe power outputs are

Página 148

Chapter 5: Troubleshooting To Check the keyboard86To Check the keyboardUse this procedure only if you encounter key

Página 149 - Theory of Operation

Chapter 5: TroubleshootingTo check the LEDs87To check the LEDsIf you see a failure with the Auto or Trig&apo

Página 150 - Figure 8-1

Chapter 5: Troubleshooting To check the motherboard, CPU, and RAM88To check the motherboard, CPU, and RAMThis proced

Página 151

Chapter 5: TroubleshootingTo check the motherboard, CPU, and RAM89Figure 5-10: Intel D915GUX Motherboard:To

Página 152

1Instruments covered by this service guide 11Accessories supplied 13Options available 15Accessories available 14Specifications & character

Página 153

Chapter 5: Troubleshooting To check the motherboard, CPU, and RAM90Figure 5-11 ADLINK M-880 MotherboardCN29CN10CN9To

Página 154 - Logic Trigger

Chapter 5: TroubleshootingTo setup the BIOS91To setup the BIOSIf the BIOS settings become corrupt, the Infin

Página 155 - Acquisition Theory

Chapter 5: Troubleshooting To troubleshoot the acquisition system92To troubleshoot the acquisition system1 Select Se

Página 156 - • Trigger levels

Chapter 5: TroubleshootingTo troubleshoot the acquisition system93Figure 5-12Acquisition Trouble IsolationAc

Página 157

Chapter 5: Troubleshooting Software Revisions94Software Revisions• Select About Infiniium... from the Help menu.A di

Página 158

6ESD Precautions 96Tools Required 96To return the oscilloscope to Agilent Technologies for service 97To remove and replace the top cover 98To

Página 159

96Replacing AssembliesUse the procedures in this chapter when removing and replacing assemblies and parts in the Agilent Technologies 8000 Series osci

Página 160

Chapter 6: Replacing AssembliesTo return the oscilloscope to Agilent Technologies for service97To return the

Página 161

Chapter 6: Replacing Assemblies To remove and replace the top cover98To remove and replace the top coverUse this pro

Página 162

Chapter 6: Replacing AssembliesTo remove and replace the bottom sleeve99To remove and replace the bottom sle

Comentários a estes Manuais

Sem comentários