Agilent Technologies, Inc.
DisplayPort Test Implementation Group 45 Agilent J-BERT N4903B & 90000A/X/Q Series Sink Draft2
Figure 42: RBR eye height boundary measurement for one level
The one level eye height boundary is the min level of the histogram. The zero level is max level of the
histogram.
Figure 43: RBR eye height boundary measurement for zero level
In this example the one level eye height boundary is 18.9mV
diff
and the zero level eye height boundary is -
24.6mV
diff
. The eye height is the delta ! 18.9mV
diff
– (-24.6mV
diff
) = 43.5mV
diff
. The target for RBR is
46mV
diff
+-10%.