1 Introduction
16 Agilent N1913/1914A EPM Series Power Meters User’s Guide
Rear Panel Connections
7
8
6
9
4
3
2
1
5
No. Connections
1 VGA Output (Option 010)
2 Ground Connector
3 USB Type A port (Option 008, Option 009)
This USB port is solely for U2000 Series power sensors usage only.
4 Recorder 1/2
Recorder output (two outputs are fitted to dual channel meters) connections are made via
BNC connectors. This output produces a DC voltage that corresponds to the power level of
the channel input.
5AC Inlet
This power meter has an auto configuring power supply. This allows it to operate over a
range of voltages without manually being set to a certain voltage.
6 Trig In/Trig Out
Trigger input and output connections are made via BNC connectors.
7USB Mini-B port
This USB port is used only for remote interface connection.
8LAN
9GPIB
This connector allows the power meter to be controlled remotely using the General Purpose
Interface Bus.