Agilent Technologies DisplayPort Manual de Serviço Página 161

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 246
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 160
Sink Eye Diagram Tests 18
Agilent U7232A DisplayPort Electrical Performance Compliance Test Application 161
10 The following select file dialog box appears. Select your coefficient file
(*.equ) and click Open. The test will run based on the your user
defined coefficient file.
PASS Condition
The following table and figure define the mask for the eye measurements.
There can be no signal trajectories entering into the mask. Table 21 shows
the voltage and time coordinates for the mask used for the eye diagram.
Figure 52 Selecting User Defined File
Vista de página 160
1 2 ... 156 157 158 159 160 161 162 163 164 165 166 ... 245 246

Comentários a estes Manuais

Sem comentários