Chapter 3 65
Basic Digital Operation
Arbitrary (ARB) Waveform Header Files
displayed alpha/symbol softkeys and the numeric keypad to
enter information such as describing the waveform’s function.
Sample Clock Rate This displays the ARB sample clock rate saved to the header.
Runtime Scaling This displays the Runtime scaling value that is saved to the
header. Runtime scaling is applied in real-time while the
waveform is playing. This setting can only be changed for files
in the dual ARB player.
Marker 1...4 Polarity This displays the marker polarity, positive or negative.
ALC Hold Routing This displays which marker, if any, will implement the ESG’s
ALC hold function. The ALC hold function holds the ALC
modulator at its current level when the marker signal is low.
When the marker signal goes high, the ALC hold function is
discontinued.
If the RF Blank Routing function is selected, it will
automatically activate the ALC hold for the same marker
number.
Alt Ampl. Routing This will display which marker, if any, will trigger the ESG’s
alternate amplitude feature when the marker signal is low.
When the marker signal goes high, the trigger is terminated
disengaging alternate amplitude. You still need to configure the
alternate amplitude parameters located in the
Amplitude
hardkey menu.
RF Blank Routing This will display which marker, if any, will implement the ESG’s
RF blanking function when the marker signal is low. RF
blanking also integrates ALC hold. So there is no need to select
the ALC Hold Routing for the same marker number when you
are using the RF Blank Routing function. When the marker
signal goes high, RF blanking is discontinued.
NOTE All waveforms generated in the ESG have a marker on the first sample point.
In order to see the desired results from the three routing selections, you may
need to select a range of sample (marker) points. Setting the marker points is
accomplished using the
Set Marker on Range of Points softkey located in the
Marker Utilities softkey menu. Refer to “Placing a Marker Across a Range of
Points within a Waveform” on page 92 for more information.
Mod Attenuation This displays the I/Q modulator attenuation setting saved to the
header.