402 Chapter 15
Signal Generator
Using the Signal Generator
Signal Generator
Using the Signal Generator
The Signal Generator is used to check the performance of base station receivers. It
supports both Received Signal Strength Indicator (RSSI) and CDMA Frame Error
Rate (FER) measurements. The Signal Generator provides multiple forward and
reverse-link modulation types. For a complete list of supported modulation types,
press the [Modulation] menu key after you begin the measurement.
CAUTION The maximum power for the RF In (Port 1) and RF Out/SWR (Port 2) ports is
+20 dBm (100 mW). When using the 8481A/8482A or N8481A/N8482A with
Option CFT Power Sensors, the maximum input power applied to the Power Sensor
is +24 dBm (300 mW). When using the 8481D Power Sensor, the maximum input
power is +20 dBm (100 mW). When directly coupled to a base station (BTS) or
Access Network (AN), the test set can be damaged by excessive power applied to
any of these three ports.
To prevent damage in most situations when you directly couple the test set to a base
station, use the high power attenuator between the test set and the BTS.
NOTE The lowest power levels the signal generator can reach for different signal formats
are shown in “Minimum and Maximum Power levels for Generated Signals” on
page 403.
In order to get a lower level, you must use an external attenuator. You can
compensate for the attenuator using RF Out Loss.
NOTE To properly test Bit Error Rate (BER) through the Receiver path on an iDEN
system, the test signal needs to be injected through the system Band Pass Filter or an
external Band Pass Filter. The system Band Pass Filter is usually integrated in the
LNA or the Duplexer, or both.
NOTE It usually takes around 5 to 10 seconds for your chosen signal to be generated, but
some signals (for example, an iDEN signal) can take up to 45 seconds. A progress
indicator shows you the percentage of the signal generation that has been completed.