Agilent B2200 Users Guide, Edition 2 5-23
SCPI Command Reference
:DIAGnostic:TEST:FRAMe[:EXECute]?
:DIAGnostic:TEST:FRAMe[:EXECute]?
This command executes the specified B2200 test, then returns the test result. See
“Selftest Menu” on page 3-34 to perform the test.
After the controller test, the B2200 status becomes same as after *RST command
execution.
Syntax :DIAGnostic:TEST:FRAMe[:EXECute]? CONTroller | FPANel |
LED | PEN | BEEPer
Query response test_result <newline><^END>
1: fail
0: pass
Example OUTPUT @Agb2200;":DIAG:TEST:FRAM? CONT"
Parameter Explanation
CONTroller Controller test
FPANel Front panel interface test
LED LED matrix test
PEN Light pen test
BEEPer Beeper test