Troubleshooting 6
U4154A Logic Analyzer Installation Guide 65
Example:
agEnableCrmConnections.cmd i386 “Local Area
Connection 2”
Ensure that the physical address of Intel PRO/1000 PL network
connection adapter is valid and ESM is reachable from the host PC
1 Type ping 169.254.1.0 in the Command shell on the host
PC. Check the results of the ping command.
2 If the ping command fails, type ipconfig/all in the
command shell and check the physical address displayed
for Intel PRO/1000 PL network connection adapter in the
command’s results.
3 If the physical address of the Intel PRO/1000 PL network
connection adapter is all zeros, reinstall the appropriate
network drivers from the <Installation directory of Logic
Analyzer>/CRMNetworkDrivers/PCIe.
Power cycle the chassis and reboot the host PC
1 Power down both host PC and AXIe chassis.
2 Power on the AXIe chassis.
3 Wait for a stead green status light to appear on the ESM
of the chassis. Wait for 2 minutes for all other
components to start properly.
4 Power on the host PC.
Parameter Description
[platform] “i386” for x86 and x64
“ia64” for Itanium 64
[connection name[ Name of the local area connection associated with
Intel PRO/1000 PL network connection adapter in
Control Panel.
[install directory] Full path where the Logic Analyzer software has
been installed. You can leave it blank if the Logic
Analyzer software has been installed at the default
location - C:\Program Files\Agilent Technologies\
Logic Analyzer.