58 U4154A Logic Analyzer Installation Guide
3 Installing Software Components
Setting up Communication between the Host PC and ESM of AXIe chassis
When you have set up the hardware and installed the Logic
Analyzer software on the host PC, perform the following
steps to ensure that the ESM communicates with the host
PC and the chassis and the application modules are ready to
use.
1 Power down both host PC and AXIe chassis in which the
U4154A module is installed.
2 Power on the AXIe chassis.
3 Wait for the OOS (Out of Service) light on the U4154A
module to turn off which indicates that the module is
functional and ready to be connected to host PC.
4 Power on the host PC.
5 Wait for the green circle icon to appear in the system tray
on the host PC. The green circle indicates that the chassis
and the module are ready to use and the communication
between the host PC and ESM of the chassis is
functioning properly.
6 If a red circle appears in the system tray instead of a
green circle, click this red circle to know the connectivity
problem. You can also refer to the “Troubleshooting" on
page 63 in this guide to know how to troubleshoot the
connectivity problems.