Performance Tests
CDMA Adjacent Channel Power (Not Used with Option UNB or Option 506)
3-33
CDMA Adjacent Channel Power
(Not Used with Option UNB or Option 506)
This automated test verifies the energy at an offset to the main channel relative to the total energy in the
main channel. Post-processing averaging techniques are used to improve repeatability.
Recommended Equipment
Agilent 8563EC Option 001 spectrum analyzer
Agilent 8491A/B Option 010 fixed attenuator (10 dB)
Equipment Setup
Figure 3-30 CDMA Adjacent Channel Power
(Not Used with Option UNB or Option 506) Setup