Agilent E6432A Microwave Synthesizer Users Guide 4-73
HPE6432_GetIfAtten
ViStatus HPE6432_GetIfAtten (ViSession instrumentHandle,
ViUInt16 *ifAttenuation);
Purpose
This function gets the IF upconverter attenuator value.
Parameter List
instrumentHandle
Variable Type ViSession
This is the ViSession handle that is obtained from the Initialize
function. The instrumentHandle identifies a particular instrument
session.
ifAttenuation
Variable Type ViUInt16 (passed by reference)
This parameter returns a value for IF Attenuation being applied.
Allowable values: 0 to 30 dB in 2 dB steps
Return Value
This parameter reports the return status of this function.
To obtain further information about the status that is returned, call the
Error Message function or refer to “Error-Code and Fail-Code
Messages” on page 3-93.