4-64 Agilent E6432A Microwave Synthesizer User’s Guide
HPE6432_GetExtTriggerOutput
ViStatus HPE6432_GetExtTriggerOutput (ViSession
instrumentHandle, ViUInt16 *trigOutFrontPanel);
Purpose
This function returns the value specified by the Set Trigger Out-
Front Panel function.
Parameter List
instrumentHandle
Variable Type ViSession
This is the ViSession handle that is obtained from the Initialize
function. The instrumentHandle identifies a particular instrument
session.
trigOutFrontPanel
Variable Type ViUInt16 (passed by reference)
This parameter returns the value specified by the Set Trigger Out-
Front Panel function.
Return Value
This return value always returns VI_SUCCESS.