Agilent Technologies U2000 Series Manual de Serviço

Consulte online ou descarregue Manual de Serviço para Redes Agilent Technologies U2000 Series. Agilent Technologies U2000 Series Technical data Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 99
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Agilent Technologies
Agilent U2000 Series
USB Power Sensors
Operating and Service
Guide
Vista de página 0
1 2 3 4 5 6 ... 98 99

Resumo do Conteúdo

Página 1 - USB Power Sensors

Agilent TechnologiesAgilent U2000 Series USB Power Sensors Operating and Service Guide

Página 2

x U2000 Series Operating and Service GuideDeclaration of Conformity (DoC)The Declaration of Conformity (DoC) for this instrument is available on the A

Página 3 - Exclusive Remedies

U2000 Series Operating and Service Guide xiContentsNotices iiCertification iiiLimitation of Warranty iiiExclusive Remedies iiiSafety Summary ivSafety

Página 4 - Safety Notices

xii U2000 Series Operating and Service Guide2 Operating InformationMeasurement Mode 22• Average only Mode 22• Normal Mode 22Power Sensor Configurat

Página 5 - Safety Symbols

U2000 Series Operating and Service Guide xiii4 ServiceGeneral Information 70• Cleaning 70• Connector Cleaning 70Performance Test 71• Standing Wave

Página 6 - Regulatory Markings

xiv U2000 Series Operating and Service GuideList of FiguresFigure 1-1 LED indicator sequence during power-up 5Figure 1-2 Block diagram of the RF/m

Página 7 - 20002/96/EC

U2000 Series Operating and Service Guide xvList of TablesTable 1-1 States of LED indicator and its description 4Table 2-1 Sensor Ranges 27Table

Página 8 - General Safety Information

xvi U2000 Series Operating and Service Guide

Página 9 - Environmental Conditions

1Agilent U2000 Series USB Power SensorsOperating and Service GuideAgilent Technologies1Getting StartedIntroduction 2Power Sensor Overview 3Principles

Página 10

1Getting Started2 U2000 Series Operating and Service GuideIntroductionThe Agilent U2000 Series USB power sensors are standalone power sensors used for

Página 11 - Contents

Getting Started 1U2000 Series Operating and Service Guide 3Power Sensor Overview1423567No. Part Functions1 RF input port Allows RF/microwave input sig

Página 12 - 2 Operating Information

ii U2000 Series Operating and Service GuideNotices© Agilent Technologies, Inc. 2007–2012No part of this manual may be reproduced in any form or by any

Página 13 - 5 Appendix

1Getting Started4 U2000 Series Operating and Service GuideLED Indicator GuideThe LED indicator is found at the rear panel of the power sensor. The fol

Página 14 - List of Figures

Getting Started 1U2000 Series Operating and Service Guide 5Figure 1-1 LED indicator sequence during power-upPower UpUSB EnumerationHW/OS ErrorSelf-tes

Página 15 - List of Tables

1Getting Started6 U2000 Series Operating and Service GuidePrinciples of Operation The U2000 Series USB power sensors function as a power meter and pow

Página 16

Getting Started 1U2000 Series Operating and Service Guide 7Sensor control and processing is provided by an embedded processor with Digital Signal Proc

Página 17 - Getting Started

1Getting Started8 U2000 Series Operating and Service GuideFigure 1-2 Block diagram of the RF/microwave USB power sensor

Página 18 - Introduction

Getting Started 1U2000 Series Operating and Service Guide 9The U2000 Series USB Power Sensors in DetailMost of the power sensors used for measuring av

Página 19 - Power Sensor Overview

1Getting Started10 U2000 Series Operating and Service GuideThis technique will ensure the diodes in the selected signal path are kept in their square

Página 20 - LED Indicator Guide

Getting Started 1U2000 Series Operating and Service Guide 11Initial InspectionInspect the shipping container for damages. If the shipping container or

Página 21 - Getting Started 1

1Getting Started12 U2000 Series Operating and Service GuideHardware Installation and ConfigurationSystem RequirementsPrior to using the U2000 Series U

Página 22 - Principles of Operation

Getting Started 1U2000 Series Operating and Service Guide 13Installing Your U2000 Series USB Power SensorU2000 Series offers USB plug- and- play capab

Página 23

U2000 Series Operating and Service Guide iiiCertificationAgilent Technologies certifies that this product met its published specifications at the time

Página 24 - 1Getting Started

1Getting Started14 U2000 Series Operating and Service GuideFigure 1-5 Found New Hardware Wizard driver installation5 A warning message will appear in

Página 25

Getting Started 1U2000 Series Operating and Service Guide 156 Click Finish when the installation has completed.Figure 1-7 Completing hardware driver

Página 26 - Milimeter-Wave Applications

1Getting Started16 U2000 Series Operating and Service GuideVerifying Your Connected Power Sensor1 To verify your connected power sensor, go to Start &

Página 27 - Initial Inspection

Getting Started 1U2000 Series Operating and Service Guide 174 To verify your connected power sensor, send the default SCPI command *IDN? to the power

Página 28 - System Requirements

1Getting Started18 U2000 Series Operating and Service GuideConfiguring Your Power Sensor via Power Analysis Manager1 Go to Start > All Programs >

Página 29

Getting Started 1U2000 Series Operating and Service Guide 19Checking the Power Sensor FirmwareThere are two ways that can be used to check the firmwar

Página 30

1Getting Started20 U2000 Series Operating and Service GuideAgilent N1918A Power Analysis ManagerBy using the N1918A Power Analysis Manager, you can ch

Página 31

21Agilent U2000 Series USB Power SensorsOperating and Service GuideAgilent Technologies2Operating InformationMeasurement Mode 22Power Sensor Configura

Página 32

2 Operating Information22 U2000 Series Operating and Service GuideMeasurement ModeThe U2000 Series USB power sensors have two measurement modes: avera

Página 33

Operating Information 2U2000 Series Operating and Service Guide 23Figure 2-1 Example of trace graph display for GSM signal

Página 34

iv U2000 Series Operating and Service GuideSafety SummaryThe following general safety precautions must be observed during all phases of operation of t

Página 35

2 Operating Information24 U2000 Series Operating and Service GuideMeasurement GateA gate, controlled by and referenced to a trigger point, is used to

Página 36

Operating Information 2U2000 Series Operating and Service Guide 25Power Sensor Configuration SettingsThe auto- averaging settings shown in Figure 2- 3

Página 37 - Operating Information

2 Operating Information26 U2000 Series Operating and Service GuideFigure 2-3 Auto-averaging settings1234111111112811151211111 1 1 10241 1 256 10241 1

Página 38 - Measurement Mode

Operating Information 2U2000 Series Operating and Service Guide 27Measurement Accuracy and Speed With U2000 Series USB power sensors, the range can be

Página 39 - Operating Information 2

2 Operating Information28 U2000 Series Operating and Service GuideThe default is “AUTO”. In AUTO the range crossover value depends on the sensor model

Página 40 - Measurement Gate

Operating Information 2U2000 Series Operating and Service Guide 29measurement of this signal. However, range holding in “UPPER” (the high power path),

Página 41

2 Operating Information30 U2000 Series Operating and Service GuideInternal and External ZeroingZeroing a power sensor is performed in order to reduce

Página 42 - 2 Operating Information

Operating Information 2U2000 Series Operating and Service Guide 31Figure 2-4 Select either INT or EXT from the Zero Type option

Página 43 - Setting the Range

2 Operating Information32 U2000 Series Operating and Service GuidePower Sweep and Frequency SweepThe frequency sweep and power sweep features provide

Página 44 - Measurement Considerations

Operating Information 2U2000 Series Operating and Service Guide 33Step DetectionTo reduce the filter settling time after a significant step in the mea

Página 45 - Speed and Averaging

U2000 Series Operating and Service Guide vSafety SymbolsThe following symbols on the instrument and in the documentation indicate precautions which mu

Página 46 - Internal and External Zeroing

2 Operating Information34 U2000 Series Operating and Service GuidePulse Power Measurement in Average only ModeThe U2000 Series USB power sensors provi

Página 47

35Agilent U2000 Series USB Power SensorsOperating and Service GuideAgilent Technologies3Specifications and CharacteristicsIntroduction 36Specification

Página 48

3 Specifications and Characteristics36 U2000 Series Operating and Service GuideIntroductionU2000 Series USB power sensors are average, wide dynamic ra

Página 49 - Step Detection

Specifications and Characteristics 3U2000 Series Operating and Service Guide 37Specification definitionsThere are two types of product specifications:

Página 50 - 30 dBm to +44 dBm

3 Specifications and Characteristics38 U2000 Series Operating and Service GuideSpecificationsFrequency and Power RangesConnector TypeModel Frequency R

Página 51 - Agilent Technologies

Specifications and Characteristics 3U2000 Series Operating and Service Guide 39Maximum SWR (25 °C ±10 °C)Model Frequency SWRU2000A10 MHz to 30 MHz 1.1

Página 52

3 Specifications and Characteristics40 U2000 Series Operating and Service GuideSWR Plots for U2000 Series USB Power SensorsFigure 3-1 U2000A typical S

Página 53 - Specification definitions

Specifications and Characteristics 3U2000 Series Operating and Service Guide 41Figure 3-2 U2001A Typical SWR (25 °C ±10 °C)Figure 3-3 U2002A Typical S

Página 54 - Specifications

3 Specifications and Characteristics42 U2000 Series Operating and Service GuideFigure 3-4 U2004A Typical SWR (25 °C ±10 °C)Figure 3-5 U2000H Typical S

Página 55 - Maximum SWR (25 °C ±10 °C)

Specifications and Characteristics 3U2000 Series Operating and Service Guide 43Figure 3-6 U2001H Typical SWR (25 °C ±10 °C)Figure 3-7 U2002H Typical S

Página 56

vi U2000 Series Operating and Service GuideRegulatory MarkingsThis symbol indicates that a device, or part of a device, may be susceptible to electros

Página 57

3 Specifications and Characteristics44 U2000 Series Operating and Service GuideFigure 3-8 U2000B typical SWR (25 °C ±10 °C) Figure 3-9 U2001B typical

Página 58

Specifications and Characteristics 3U2000 Series Operating and Service Guide 45Maximum SWR (0 °C to 55 °C)Model Frequency SWRU2000A10 MHz to 30 MHz 1.

Página 59

3 Specifications and Characteristics46 U2000 Series Operating and Service GuideU2000H10 MHz to 8 GHz 1.178 GHz to 12.4 GHz 1.2612.4 GHz to 18 GHz 1.29

Página 60

Specifications and Characteristics 3U2000 Series Operating and Service Guide 47Maximum PowerModels Maximum PowerU2000/1/2A +25 dBm (320 mW) average, 2

Página 61 - Maximum SWR (0 °C to 55 °C)

3 Specifications and Characteristics48 U2000 Series Operating and Service GuidePower AccuracyThis specification is valid only after zeroing and calibr

Página 62

Specifications and Characteristics 3U2000 Series Operating and Service Guide 49Power Accuracy Plots (Average only Mode)Figure 3-10 Typical power accur

Página 63 - Maximum Power

3 Specifications and Characteristics50 U2000 Series Operating and Service GuideFigure 3-12 Typical power accuracy at 25 °C for U2000/1/2H models1, 21

Página 64 - Power Accuracy

Specifications and Characteristics 3U2000 Series Operating and Service Guide 51Switching PointThe U2000 Series USB power sensors have two measurement

Página 65 - 25 °C for U2000/1B models

3 Specifications and Characteristics52 U2000 Series Operating and Service GuideExamples U2000/1/2/4A Power SensorsThe switching point for U2000/1/2/4A

Página 66 - for U2000/1/2H models

Specifications and Characteristics 3U2000 Series Operating and Service Guide 53Zero Set, Zero Drift, and Measurement NoiseAverage only ModeFor U2000/1

Página 67 - Switching Point

U2000 Series Operating and Service Guide viiWaste Electrical and Electronic Equipment (WEEE) Directive 20002/96/ECThis instruction complies with the W

Página 68 - U2000/1B Power Sensors

3 Specifications and Characteristics54 U2000 Series Operating and Service GuideFor U2000/1B,Range1Zero Set (Internal) Zero Set (External) Zero Drift2M

Página 69 - Average only Mode

Specifications and Characteristics 3U2000 Series Operating and Service Guide 55Effects of Averaging on Average only Mode Measurement NoiseAveraging ov

Página 70

3 Specifications and Characteristics56 U2000 Series Operating and Service GuideNormal ModeFor U2000/1/2A,For U2000/1/2H,Range1Zero Set (Internal) Zero

Página 71

Specifications and Characteristics 3U2000 Series Operating and Service Guide 57For U2000/1B,Effect of Time-Gating and Averaging on Normal Mode Measure

Página 72 - Normal Mode

3 Specifications and Characteristics58 U2000 Series Operating and Service GuideExample:U2000A power sensor, measured power = –4 dBm, gate length = 1.3

Página 73

Specifications and Characteristics 3U2000 Series Operating and Service Guide 59Settling timeIn FAST mode (using Free Run trigger), for a 10 dB decrea

Página 74

3 Specifications and Characteristics60 U2000 Series Operating and Service GuideFor auto filter, default resolution, and a 10 dB decreasing power step

Página 75 - Settling time

Specifications and Characteristics 3U2000 Series Operating and Service Guide 61Calibration Factor and Reflection Coefficient The Calibration Factor (C

Página 76

3 Specifications and Characteristics62 U2000 Series Operating and Service GuideCal Factor Uncertainty FrequencyU2000ATypical CF Uncertainty (25 °C ±10

Página 77

Specifications and Characteristics 3U2000 Series Operating and Service Guide 63Frequency U2004ATypical CF Uncertainty (25 °C ±10 °C)9 kHz to 2 GHz 1.8

Página 78 - Cal Factor Uncertainty

viii U2000 Series Operating and Service GuideGeneral Safety InformationThe following general safety precautions must be observed during all phases of

Página 79

3 Specifications and Characteristics64 U2000 Series Operating and Service GuideFrequencyU2001HTypical CF Uncertainty (25 °C ±10 °C)10 MHz to 6 GHz 2.0

Página 80

Specifications and Characteristics 3U2000 Series Operating and Service Guide 65TriggerInternal TriggerResolution 0.1 dBLevel accuracy ± 1 dBJitter ± 1

Página 81

3 Specifications and Characteristics66 U2000 Series Operating and Service GuideNormal Mode Key Specifications and CharacteristicsParameters11 Not appl

Página 82

Specifications and Characteristics 3U2000 Series Operating and Service Guide 67General CharacteristicsPhysical CharacteristicsNet WeightU2000/1/4A 0.2

Página 83 - General Characteristics

3 Specifications and Characteristics68 U2000 Series Operating and Service Guide

Página 84

69Agilent U2000 Series USB Power SensorsOperating and Service GuideAgilent Technologies4ServiceGeneral Information 70Performance Test 71Replaceable Pa

Página 85

4Service70 U2000 Series Operating and Service GuideGeneral Information This chapter contains information about general maintenance, performance tests,

Página 86 - General Information

Service 4U2000 Series Operating and Service Guide 71Performance TestStanding Wave Ratio (SWR) and Reflection Coefficient (Rho) Performance Test This s

Página 87 - Performance Test

4Service72 U2000 Series Operating and Service GuideTable 4-3 Power Sensor SWR and Reflection Coefficient for the U2002ATable 4-4 Power Sensor SWR an

Página 88

Service 4U2000 Series Operating and Service Guide 73Table 4-6 Power Sensor SWR and Reflection Coefficient for the U2001HTable 4-7 Power Sensor SWR a

Página 89

U2000 Series Operating and Service Guide ixEnvironmental ConditionsThis instrument is designed for indoor use only. The table shows the general requir

Página 90 - Replaceable Parts

4Service74 U2000 Series Operating and Service GuideReplaceable Parts Table 4- 10 contains a list of replaceable parts. To order a part, quote the Agil

Página 91

Service 4U2000 Series Operating and Service Guide 75Table 4-10 Replaceable PartsModelAgilent PartNumberQty DescriptionU2000AU2000-60006 1 U2000A repl

Página 92 - Service

4Service76 U2000 Series Operating and Service GuideService The following service instructions consist of information on troubleshooting, and repairs.T

Página 93 - Disassembly Procedure

Service 4U2000 Series Operating and Service Guide 77Disassembly and Reassembly Procedure Disassembly ProcedureDisassemble the power sensor by performi

Página 94 - Reassembly instructions:

4Service78 U2000 Series Operating and Service GuideReassembly Procedure Tools required for reassembly:Reassembly instructions:The reassembly procedure

Página 95 - U2000B and U2001B

Service 4U2000 Series Operating and Service Guide 79Attenuator Disassembly and Reassembly Procedure for U2000B and U2001BDisassembly ProcedureTools re

Página 96

4Service80 U2000 Series Operating and Service GuideReassembly ProcedureTools required for reassembly:Table 4-13 Attenuator Reassembly ProcedureTools

Página 97 - Appendix

81Agilent TechnologiesAgilent U2000 USB Power SensorsOperating and Service GuideAppendix Appendix A: Zero Set, Zero Drift, and Measurement Noise 82

Página 98

82 Agilent U2000 Operating and Service GuideAppendixAppendix A: Zero Set, Zero Drift, and Measurement NoiseThe following specifications in Table 5- 1

Página 99

www.agilent.comAgilent Technologies© Agilent Technologies, Inc. 2007–2012Printed in MalaysiaSeventh Edition, May 17, 2012U2000-90405Contact usTo obtai