Appendix A Specifications
114 Model N6705A User’s Guide
Supplemental Characteristics (continued)
N6751A / N6752A N6754A N6761A / N6762A
Up-programming Settling Time with full resistive load: (time from start of voltage change to 0.1% of full scale value)
Small voltage step 0 V to 10 V 0 V to 15 V 0 V to 10 V
Time 0.5 ms 0.8 ms 0.9 ms
Large voltage step 0 V to 50 V 0 V to 60 V 0 V to 50 V
Time 4 ms 4.2 ms 4 ms
Down-programming Time with no load: (time from start of voltage change to output voltage < 0.5 V)
Small voltage step 10 V to 0 V 15 V to 0 V 10 V to 0 V
Time 0.3 ms 0.6 ms 0.3 ms
Large voltage step 50 V to 0 V 60 V to 0 V 50 V to 0 V
Time 1.3 ms 2.2 ms 1.3 ms
Down-programming Settling Time with no load: (time from start of voltage change to 0.1% of full scale value)
Small voltage step 10 V to 0 V 15 V to 0 V 10 V to 0 V
Time 0.45 ms 0.8 ms 0.45 ms
Large voltage step 50 V to 0 V 60 V to 0 V 50 V to 0 V
Time 1.4 ms 2.3 ms 1.4 ms
Down-programming Time with Capacitive load: (time from start of voltage change to output voltage < 0.5 V)
Small voltage step 10 V to 0 V 15 V to 0 V 10 V to 0 V
Time 2.1 ms 2.3 ms 4.5 ms
Large voltage step 50 V to 0 V 60 V to 0 V 50 V to 0 V
Time 11 ms 10 ms 23 ms
Capacitive load
1000μF
NOTE 3
680μF
NOTE 4
1000μF
NOTE 3
Down-programming Capability:
Continuous power 7 W 12.5 W 7 W
Peak current 7 A 6 A 3.8 A
Over-voltage Protection:
Accuracy 0.25% + 0.25 V
0.25% + 0.6 V
NOTE 5
0.25% + 0.25 V
Maximum setting 55 V 66 V 55 V
Response time 50 μs from occurrence of over-voltage condition to start of output shutdown
Output Ripple and Noise: (PARD)
CC rms: 2 mA 4 mA 2 mV
Common Mode Noise: (from 20 Hz – 20 MHz; from either output to chassis)
rms 500 μA 750 μA 500 μA
peak-to-peak < 2 mA < 3 mA < 2 mA
Remote Sense Capability:
Outputs can maintain specifications with up to a 1-volt drop per load lead.
Series and Parallel Operation:
Identically rated outputs can be operated directly in parallel or be connected for straight
series operation. Auto-series and auto-parallel operation is not available.
3
Modules can discharge a 1000μF capacitor from fill scale to 0V at a rate of 4 times/second.
4
Modules can discharge a 680μF capacitor from fill scale to 0V at a rate of 4 times/second.
5
Accuracy is 0.25% + 600 mV with relay option 760 or 761 installed.