7
Serial BERT N4906B, Data Sheet V.3 7
The pattern generator generates hardware-based
PRBS up to 2
31
-1 and user defined patterns. It
provides a memory depth of 32 Mbit. Pattern
format is compatible within the N4900 series.
Therefore user defined patterns can be trans-
ferred across the N4900 serial BERT series.
Features:
Differential outputs
Adjustable output
Amplitude and levels
Clock/data relative delay adjustment
Adjustable crossing point
Output blanking (burst mode)
Error insertion
Trigger output
Alternating pattern
•
•
•
•
•
•
•
•
•
Figure 11: Front view of pattern generator
Pattern Generator
Waveform example for differential data output
Data Output
Table 1: Parameters for N4906B serial BERT generator. All
timing parameters are measured at ECL levels.
Range of operation
Option 003 150 Mb/s
1)
to 3.6 Gb/s
Option 012 9.5 Gb/s to 12.5 Gb/s
Option 102
2)
150 Mb/s
3)
to 12.5 Gb/s
Format NRZ, normal or inverted
Amplitude/resolution 0.1 V to 1.8 V/ 5 mV steps
Output voltage window -2.0 V to +3.0 V
Predefined levels ECL, PECL (3.3 V), LVDS,
CML
Data interface
4)
Differential or single-ended
DC coupled, 50 Ω
Transition times
20% to 80% < 20 ps typ.
10% to 90% < 25 ps
5)
With N4915A-001 < 50 ps typ.
6)
transition time converter
Jitter 9 ps pp typ.
Clock/data delay range ±0.75 ns
Resolution 100 fs
External termination -2 V to +3 V
voltage
7)
Crossing point 20%.......80% typ. adjustable
Single error inject Adds single errors on
demand
Fixed error inject Fixed error ratios of 1 error
in 10
n
bits, n = 3, 4, 5, 6,
7, 8, 9
Connector 2.4 mm female
2.4 mm to 3.5 mm adapters
are included
1) 150 MHz to 3.6 GHz external clock, 620 Mb/s to 3.6 Gb/s
internal clock.
2) Only in combination with option 012.
3) 150 MHz to 12.5 GHz external clock, 620 Mb/s to 12.5 Gb/s
internal clock.
4) Unused outputs must be terminated with 50 Ω to GND.
5) Only option 012 at 10 Gb/s.
6) Recommended for option 003.
7) For positive termination voltage or termination to GND,
external termination voltage must be less than 3 V below
VOH. For negative termination voltage, external termination
voltage must be less than 2 V below VOH. External termina-
tion voltage must be less than 3 V above VOL.
Figure 12: Output signal at 50% crossing point and 12.5 Gb/s
(option 012)
dataTec GmbH
•
Ferdinand-Lassalle-Str. 52
•
72770 Reutlingen
•
Tel. 07121 / 51 50 50
•
Fax 07121 / 51 50 10
•
info@datatec.de
•
www.datatec.de
Comentários a estes Manuais