Recommended Probes for Low-/Mid-Speed Bus Measurements
Applications Speed and signal type Recommended probe Required probe bandwidth
LIN 10 kHz, single-ended SE passive > 100 MHz
ARINC 425 1000 kbps, differential N2792A/N2818A 200 MHz
CAN 1 Mbps, differential N2792A/N2818A 200 MHz
MIL-STD 1553 1 Mbps, differential
±25 Vpp
N2792A/N2818A 200 MHz
I²S (audio) ~2.8 MHz, single-ended SE passive > 100 MHz
I²C/SMbus < 4 MHz, single-ended SE passive > 100 MHz
RS232/UART < 10 Mbps, single-ended SE passive > 100 MHz
RS422/485 10 Mbps, differential N2792A/N2818A 200 MHz
FlexRay 10 Mbps, differential N2792A/N2818A 200 MHz
SPI 1 – 100 MHz, single-ended SE passive or N2795A > 100 MHz passive or 1 GHz active
MOST 150 Mbps, differential N2750A 1.5 GHz
USB 2.0 480 Mbps, differential N2750A 1.5 GHz