Agilent N6705 DC Power Analyzer Supplemental Characteristics
Supplemental characteristics are not warranted but are descriptions of performance determined either by design or by type testing.
All supplemental characteristics are typical unless otherwise noted.
Arbitrary waveform generator maximum bandwidth
Maximum bandwidth is based on a sine wave into a resistive load and applies to any output current level. In the tables below, THD means
Total Harmonic Distortion, Vp-p means volts peak-to-peak, 3 dB max frequency is the frequency where the output voltage drops to 3 dB below
the programmed value, and 6 dB max frequency is the frequency where the output voltage drops to 6 dB below the programmed value.
N6780 Series 2-quadrant source/measure units
SMU maximum bandwidth is > 10 kHz. Contact Agilent Technologies for more information about SMU bandwidth.
N6750 High-performance autoranging DC power modules and N6760 precision DC power modules
N6751
Frequency below
N6752 3 dB max THD at 3 dB which THD is
frequency max frequency less than 1.5%
0.5 Vp-p 4000 Hz 12.0% 440 Hz
1 Vp-p 2200 Hz 21.0% 440 Hz
2.5 Vp-p 900 Hz 25.0% 265 Hz
5 Vp-p 500 Hz 27.0% 160 Hz
50 Vp-p 340 Hz 22.0% 25 Hz
N6754
Frequency below
3 dB max THD at 3 dB which THD is
frequency max frequency less than 1.5%
0.6 Vp-p 3600 Hz 6.0% 2100 Hz
1.2 Vp-p 2600 Hz 10.0% 1280 Hz
3 Vp-p 1700 Hz 17.0% 800 Hz
6 Vp-p 1000 Hz 17.0% 480 Hz
60 Vp-p 340 Hz 22.0% 30 Hz
N6761
Frequency below
N6762 3 dB max THD at 3 dB which THD is
Frequency max frequency less than 1.5%
0.5 Vp-p 4500 Hz 14.0% 450 Hz
1 Vp-p 3600 Hz 14.0% 450 Hz
2.5 Vp-p 1300 Hz 25.0% 340 Hz
5 Vp-p 600 Hz 25.0% 250 Hz
50 Vp-p 350 Hz 22.0% 30 Hz