Register-Based Programming 141
Multimeter status bit 5 (multimeter complete) is monitored to
determine when the analog-to-digital (A/D) conversion is in progress,
and thus, when to advance the channel. This enables each channel to
be measured before the readings are read from the buffer.The channel
can also be advanced by monitoring bit 4 (Data Ready). However,
before measuring the next channel, readings from the previous channel
must be read from the buffer in order to clear the bit.
Multimeter Autozero is often turned on in order to detect when bit 5 is
active.
Programming Example
The example in this section demonstrate how to program the multiplexer in
register format. This example includes:
Reading the ID, Device Type, and Status Registers
Closing/Opening a channel, Stand-Alone Multiplexer Measurements
Scanning through channels
System
Configuration
The following programs were developed on an embedded controller using
Visual C/C++ programming language and using the SICL interface library.
You can also use an external PC connected via GPIB to an Agilent E1406A
Command Module. The command module simply provides direct access to
the VXI backplane.
Example Program The following example program contains segments that:
Read the ID and Device Type Registers.
Read the Status Register.
Close a group of channels and the associated tree relay.
Resets the module to open all channels.
Scans through all the channels on the module.