Agilent Technologies U2802A Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Medição, teste e controlo Agilent Technologies U2802A. Agilent USB Modular Data Acquisition Modules Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 74
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Agilent
USB Modular Products
Data Sheet
Introduction
Agilent´s compact USB modular
products are a series of modules that
are flexible to be used standalone or
plugged into a compatible chassis to
make synchronized measurements
as a modular unit. Essential
measurements can be made with a
laptop PC and these modules through
USB high-speed 2.0 connections.
Through individual windows, the
Agilent Measurement Manager
(AMM) software provides a friendly
soft front-panel interface for each
of the modular products. This helps
to perform quick configuration and
measurement acquisition as well as
flexible analysis of measured data.
Simple setup with USB Hi-Speed 2.0 and
bundled software
Easy to program with AMM software, IVI
drivers, and a wide range of Application
Development Environment compatibility
Portable and compact
Flexibility with standalone/modular
capability
Vista de página 0
1 2 3 4 5 6 ... 73 74

Resumo do Conteúdo

Página 1 - USB Modular Products

Agilent USB Modular ProductsData SheetIntroductionAgilent´s compact USB modular products are a series of modules that are flexible to be used standalo

Página 2 - Overview

10U2781AMechanical specificationsPhysical layoutNumber of USB module slots 6Dimension of each module slot 25.40 mm (W) x 174.54 mm (D) x 105.00 mm (H)D

Página 3

11AMMAgilent Measurement Manager PrerequisitesPrior to installing the Agilent Measurement Manager software, ensure that your PC meets the following mi

Página 4

12DAQAgilent USB Modular Data Acquisition Modules[1] Aggregate sampling rate.[2] Works with U2355A and U2356A models.The USB data acquisition (DAQ) fa

Página 5

13U2300AFeaturesUp to 3 MSa/s sampling rate for a single channelFunctions as a standalone or modular unitEasy to use: Plug-and-play and hot-swap

Página 6 - Supported products

14U2300AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [1]POWER REQUIREMENT+12 VDC (TYPICAL)• 2 A

Página 7

15U2300AElectrical specificationsBasic multifunction USB DAQModel number U2351A U2352A U2353A U2354AAnalog inputResolution 16 bits, no missing codesNum

Página 8

16U2300ABasic multifunction USB DAQ (continued)Digital I/ONumber of channels 24-bit programmable input/outputCompatibility TTLInput voltageVIL = 0.7 V

Página 9

17U2300AHigh density multifunction USB DAQModel number U2355A U2356A U2331AAnalog inputResolution 16 bits, no missing codes 12 bits, no missing codesN

Página 10 - Mechanical specifications

18U2300AHigh density multifunction USB DAQ (continued)General purpose digital counterMaximum count (2³¹ – 1) bitsNumber of channels Two independent up

Página 11 - Agilent Measurement Manager

19U2300AElectrical measurement specificationsBasic multifunction USB DAQModel number U2351A, U2352A U2353A, U2354AAnalog input measurement[1]Function 2

Página 12

2OverviewTable of ContentsOverview ...2Agilent U2781A USB Modular

Página 13 - Introduction

20U2300AHigh density multifunction USB DAQModel number U2355A U2356A U2331AAnalog input measurement[1]Function23 °C ± 5 °C0 °C to 18 °C 28 °C to 45 °

Página 14

21U2300AHigh density multifunction USB DAQ (continued)Model number U2355A, U2356A U2331AAnalog output measurement[1]Function 23 °C ± 5 °C0 °C to 18 °C

Página 15 - Electrical specifications

22U2300ADC CharacteristicsAccuracy SpecificationsModel Number U2351A, U2352A, U2353A, U2354AAnalog InputUnipolar Range (V) Offset Error (mV)[1]Gain Err

Página 16

23U2300AAccuracy Specifications (Continued)Model U2331ABipolar Range (V) Offset Error (mV)[1]Gain Error (mV) Accuracy (% of reading + offset error)[2]1

Página 17

24U2500AVarious features of the U2500A SeriesQuick and easy USB setupHigh sampling rate of up to 2 MSa/s for each channelDedicated analog-to-digit

Página 18

25U2500AProduct characteristics and General Specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [1]POWER REQUIREMENT+12 VDC (TYPICAL)• 2 A

Página 19 - Basic multifunction USB DAQ

26U2500AProduct specificationsModel number U2531A U2541A U2542AAnalog inputResolution 14 bits 16 bitsNumber of channels 4 differential input channels (

Página 20

27U2500AProduct specifications (continued)Model number U2531A U2541A U2542AAnalog triggerTrigger source All analog input channels, External analog trig

Página 21

28U2500AElectrical specifications and characteristicsAnalog input characteristics[1]Model number U2531A U2541A U2542A23 °C ± 5 °C0 °C to 18 °C 28 °C to

Página 22 - DC Characteristics

29U2500ATest conditionDynamic range test for U2500A Series DAQ devicesDynamic range test Model Test conditions (DUT setting at ±10 V bipolar)SFDR, THD

Página 23

3Agilent USB Modular Data Acquisition (DAQ) FamilyU2300A Series USB Modular Multifunction DAQ U2600A Series USB Modular Isolated Digital I/OFeatures:H

Página 24

30U2500ATypical performance graph

Página 25

31U2500ADC characteristicsAccuracy specifications[1]Model U2541A, U2542AAnalog inputUnipolar range (V) Offset error (mV)[2]Gain error (mV) Accuracy (%

Página 26 - Product specifications

32U2600AVarious features to meet industrial demandsQuick and easy USB setupHigh channel count to drive more actuators and control more sensors by

Página 27

33U2600AHigh channel count with opto-isolated digital input and digital outputThe U2600A Series has high channel count with up to 64-bit high-density

Página 28 - Analog output characteristics

34U2600AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [1]POWER REQUIREMENT+12 VDC (TYPICAL)• 2 A

Página 29 - Test condition

35U2600AProduct specificationsModel number U2651A U2652A U2653ADigital inputNumber of isolated bits 32-bit 64-bit -Input type Opto-isolated Opto-isolat

Página 30 - Typical performance graph

36U2802AFeaturesUp to 31 thermocouple inputsSupports thermocouple type J, K, R, S, T, N, E, and BUp to 10 V voltage input rangeOpen thermocouple

Página 31 - DC characteristics

37U2802AThermocouple input modeIn thermocouple input mode, the U2802A can acquire up to ±100 mV input signals. Each channel includes an instrumentatio

Página 32

38U2802AProduct characteristics and general specificationsPOWER CONSUMPTION+12 VDC, 480 mA maximumOPERATING ENVIRONMENTOperating temperature from 0 °C

Página 33

39U2802AProduct specificationsGeneral characteristicsNumber of channels 31 differential and 1 CJCInput voltage range for voltage mode ±10 V (signal + c

Página 34

4Agilent USB Modular Test Instruments FamilyU2701A/U2702A USB Modular OscilloscopeU2741A USB Modular Digital Multimeter (DMM)U2722A/U2723A USB Modular

Página 35

40U2802AThermocouples typical measurement accuracyThe U2802A measurement error with U2355A or U2356A at 23 °C ± 5 °C is shown below.

Página 36 - Features to meet your demands

41U2802ASystem accuracy specificationsThe U2802A system accuracy specifications are shown in Table 1, Table 2, and Table 3. These measurements are deri

Página 37

42U2802ATable 3. Measurement accuracy of the U2356A at 0 to 18 °C and 28 to 45 °CThermocouple measurement accuracy (U2356A @ 0 to 18 °C and 28 to 45

Página 38

43DAQOptional Acessories for USB Modular DAQU2901/U2902A — Terminal block and SCSI-II 68-pin connector with 1-meter/2-meter cableTerminal block overvi

Página 39

44DAQU2903/U2904A - Terminal block and SCSI-II 100-pin connector with 1-meter/2-meter cableTerminal block overviewFront viewSide view103.00 mm85.20 mm

Página 40

45Modular Test InstrumentsAgilent USB Modular Test Instrument ModulesAgilent´s growing family of USB-based modular test instruments now includes oscil

Página 41 - System accuracy specifications

46U2701A/U2702AU2701A and U2702A USB Modular OscilloscopeFeatures100 MHz and 200 MHz bandwidthsUp to 1GSa/s maximum sample rate32 Mpts of waveform

Página 42

47U2701A/U2702AWhy do you need Deep Memory and a High Sampling Rate?To see more timeWhen you are able to store more samples that you have obtained in

Página 43

48U2701A/U2702AFeatures you needThe U2701A and U2702A includes the following standard features that you need to perform your tasks efficiently:Hi-Spee

Página 44 - Terminal block overview

49U2701A/U2702AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC 488.2 Class device• POWER CONSUMPTION+12 VD

Página 45

5Compatible with a Wide Range of Application Development EnvironmentsThe Agilent USB modular products are compatible with a wide range of application

Página 46

50U2701A/U2702APerformance specifications[1]Vertical system: oscilloscope channelsBandwidth (–3 dB) U2701A: DC to 100 MHzU2702A: DC to 200 MHzScope cha

Página 47 - Ease of use

51U2701A/U2702APerformance characteristics[1] (continued)Vertical system: oscilloscope channels (continued)Single-cursor accuracy ±{DC vertical gain a

Página 48 - Features you need

52U2701A/U2702APerformance characteristics[1] (continued)External (EXT) triggering (continued)Trigger level sensitivity For ±1.25 V range setting:DC t

Página 49 - U2701A/U2702A

53U2722A/U2723AIncreases productivity and accuracy in automated testingFour-quadrant operations well suited for a wide range of test applications wi

Página 50 - Performance characteristics

54U2722A/U2723AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [1]POWER CONSUMPTION+12 VDC, 3 A m

Página 51 - (continued)

55U2722A/U2723AProduct specificationsGeneralModel U2722A/U2723ANumber of outputs 3Output ratings (at 0 °C to 50 °C)Voltage –20 V to 20 VCurrent –120 mA

Página 52

56U2722A/U2723APerformance characteristicsRise/fall time (ms)[1]For resistive measurement[2]±1 μA 170.0 15.0±10 μA 18.0 5.0±100 μA 6.0 1.0±1 mA 1.0 1.

Página 53

57U2741AFeaturesMakes fast measurements with up to 100 readings per second Measures up to 300 VDC with 5½-digits resolutionFrequency and temperat

Página 54 - U2722A/U2723A

58U2741AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0* • USBTMC-USB488• [1]POWER CONSUMPTION+12 VDC, 2 A maximum

Página 55

59U2741AProduct specificationsDC specifications[1]Function Range Input impedanceTest current/ Burden voltage, Shunt resistanceAccuracy ±(% of reading +

Página 56

6U2781AIntroductionThe Agilent U2781A USB modular product chassis is a high-performance 4U chassis that comes with a 200 W universal AC power supply a

Página 57

60U2741A[1] Specifications are based on 30 minutes warm-up time and calibration temperature within 18 °C to 28 °C. In manual range, the settling time

Página 58 - Top view

61U2741A[1] Frequency measurement can only be done in auto range mode. Specifications are for 30 minutes warm-up time, using one second aperture. Measu

Página 59

62U2751AAffordable, reliable, and flexible switching solutionMinimal crosstalk at up to 45 MHz for more accurate measurementsBandwidth of 45 MHz with

Página 60 - AC specifications

63U2751AAgilent U2922A 32-Channel Terminal BlockThe U2922A terminal block is an optional accessory to be used with the U2751A. The U2922A, which weigh

Página 61 - Temperature specifications

64U2751AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [1]POWER CONSUMPTION+12 VDC, 2 A maximum•

Página 62

65U2751AProduct specificationsModelU2751AWithout U2922A terminal block With U2922A terminal blockChannels/configuration 4 × 8, 2-wireSwitch type Armatur

Página 63

66U2761AIntroductionThe Agilent U2761A is a 20 MHz USB modular function generator with arbitrary waveform and pulse generation capability. It can oper

Página 64

67U2761AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [1]POWER CONSUMPTION+12 VDC, 2 A• Isolated

Página 65

68U2761AProduct specifications and measurement characteristicsWaveformsStandard Sine, Square, Ramp, Triangle, Pulse, DCBuilt-in arbitrary Exponential R

Página 66

69U2761AWaveform characteristics (continued)ArbitraryFrequency range 1 μHz to 200 kHz (1 μHz resolution)Waveform memory depth 64 kSaAmplitude resoluti

Página 67

7U2781ATriggering using Star trigger busThe U2781A comes with a Star trigger bus, which offers precise synchronization between USB modular products an

Página 68

70U2761ATrigger characteristicsTrigger inputInput Level TTL compatibleSlope Rising and Falling, SelectablePulse width > 100 nsInput impedance >

Página 69

71U2761ASweep CharacteristicsWaveforms Sine, Square, Ramp, ArbitraryType Linear or LogarithmicDirection Up or DownSweep time 1 ms to 500 sTrigger Sing

Página 70

72Ordering InformationPart number DescriptionU2781A USB modular product chassisU2905A Rackmount kitU2300A Series USB modular multifunction DAQ U2331A

Página 71

73Ordering InformationPart number DescriptionU2701A USB modular oscilloscope (100 MHz)/U2702A USB modular oscilloscope (200 MHz)N2862A 10:1 passive pr

Página 72 - Ordering Information

Remove all doubtOur repair and calibration services will get your equipment back to you, performing like new, when prom-ised. You will get full value

Página 73

8U2781AProduct characteristics and general specifi cationsREMOTE INTERFACEHi-Speed USB 2.0*• USBTMC-USB488• [5]POWER CONSUMPTION400 VA maximum• Install

Página 74 - Remove all doubt

9U2781AElectrical specificationsPower supply AC inputInput voltage range 100 to 240 VACInput frequency range 50 to 60 HzPower consumption 400 VA maximu

Comentários a estes Manuais