Local Terminal Configuration
Using the Main Menu
19
Using the Main Menu
To configure the probe, connect a terminal directly to the probe and use the probe
Main Menu.
NOTE
The probe is not available to the network when you are using the configuration
menus.
To view the probe Main Menu:
1. Connect a terminal or a personal computer (PC) emulating a terminal to the
probe RS-232 connector using a null modem cable. Refer to Appendix A,
“Cables and Connectors” on page 113 for more information on cables.
2. Configure the terminal for 8 bits/character, 1 stop bit, no parity, Xon/Xoff
handshaking, and a baud rate of 9600.
3. Connect the power cord to the probe and to a power source (either 100-120/
VAC or 220-240/VAC). The probe does not have a power switch, but is
turned on by connecting to a power source.