Agilent Technologies 34450A Guia do Utilizador Página 105

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 140
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 104
Measurement Tutorial 3
34450A User’s Guide 83
Considering the internal resistance and external lead
resistance total is 0.0125 ohm. If applying a 1 A DC current,
an error of (0.0125 ohm x 1 A) 0.0125 V or 12.5 mV will
occur. This error will be relative by range with the ADC
dynamic range of 1.2 V.
Figure 3-4 Example of measuring voltage and current in dual measure-
ment
The error in measurement will be significant when applying a higher
current.
Vista de página 104
1 2 ... 100 101 102 103 104 105 106 107 108 109 110 ... 139 140

Comentários a estes Manuais

Sem comentários