© Agilent Technologies 2001–2002 Administering Agilent 3070 Systems (MS Windows NT and 2000) 8-12
Chapter 8: Reference
5 Copy the appropriate
statements from the system
config file to the clipboard
buffer:
In the BT-BASIC window containing the system config file:
a Press F1 on the keyboard to enter the workspace.
b Locate the module <number> that contains un-commented
cards 1 ... statements using the arrow keys or the Prev and Next keys.
c Scroll the text up until the end module statement is visible.
d Click and drag with the mouse to highlight the text including the ports ...
statement
The highlighted text is now copied in the clipboard buffer.
NOTE
Do not include probe, debug port, bank, or end bank statements.
These statements are not valid in the standard config file.
Table 8-6 Resolve the standard config file from the system config file (continued)
Task Step