Agilent Technologies Ininiium 90000 Especificações

Consulte online ou descarregue Especificações para Multímetros Agilent Technologies Ininiium 90000. Agilent Technologies Ininiium 90000 Specifications Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir

Resumo do Conteúdo

Página 1 - Data Sheet

Agilent Infiniium 90000 X-Series OscilloscopesCombining deep logic analysis with the industry’s highest performance oscilloscopeFeaturing the world’s

Página 2 - 33 GHz and still improving

10Analysis tools: PrecisionProbe (option 001)Turn your 90000 X-Series oscilloscope into a time-domain transmissometry (TDT) and quickly characterize

Página 3

11Analysis tools: EZJIT, EZJIT + and SDA (standard on DSA models)Gain insight into the causes of signal jitter to ensure high reliability of your desi

Página 4

12Analysis tools: EZJIT Complete (standard on DSA models)Discover signal anomalies to the noise of the waveformMore than your standard jitter packageI

Página 5

13Analysis tools: InfiniiSim (options 013 and 014)The most advanced waveform transformation software helps you render waveforms anywhere in a digital

Página 6 - Low noise floor

14Analysis tools: Serial data equalization (option 012)Significantly reduce receiver errors by opening even tightly shut eyes through equalization emu

Página 7

15Analysis tools: N8900A InfiniiView oscilloscope analysis softwareView and analyze away from your scope and target systemEver wish you could do addit

Página 8

16Analysis tools: User-defined function (option 065)Combine Infiniium and MATLAB for even more analysisEnhance the 90000 X-Series with a seamless gate

Página 9 - Industry’s only bandwidth

17Compliance and automated testingCompliance applications make testing to today’s technologies standards easy The remote programming interface makes i

Página 10

18Compliance and automation testing: Switch matrix supportComprehensive testing, eastily achievedEliminate reconnections (reducing errors)Compliance a

Página 11 - Unique RJ/DJ threshold view

19Compliance and automation testing: User-defined application (option 040)Custom automation for your 90000 X-Series oscilloscopeThe user-defined appli

Página 12 - Key measurements

2Engineered for 33 GHz true analog bandwidth that delivers:Need bandwidth? When you’re deploying leading edge high-speed serial bus designs like Fibre

Página 13 - Model your system with as

20Compliance and automation testing: Other options on 90000 X-Series oscilloscopesIn the previous pages we have highlighted a few of the key technolog

Página 14 - (Option 009)

21Protocol and triggering: Memory support (standard feature on the MSOX)DDR2, 3, and 4 protocol and triggering Because of the introduction of MSO mode

Página 15

22Protocol analysis90000 X-Series oscilloscopes come with more than 15 protocol decoders, including the industry’s only 64/66b decoder. The 90000 X-Se

Página 16

23Agilent Infiniium Oscilloscope Portfolio Agilent’s Infiniium oscilloscope lineup includes bandwidths from 600MHz to 63 GHz. Use the following selec

Página 17

24Engineered for 33 GHz true analog bandwidth that delivers Configure your high performance real-time oscilloscope solution todayGet the most out of

Página 18 - Switch matrix

25Description Options Model numberANSI Z540 Compliant calibration DSOX90000-A6JISO17025 calibration DSOX90000-1A7DVD RW DSOX90000-820 N5473AGPIB card-

Página 19 - PrecisionProbe and switch

26Engineered for 33 GHz true analog bandwidth that delivers Configure your high performance real-time oscilloscope solution todayCompliance Testing

Página 20

27Bandwidth upgradesN5471M 13 GHz to 16 GHz Bandwidth upgradeN5471G 16 GHz to 20 GHz Bandwidth upgradeN5471H 20 GHz to 25 GHz Bandwidth upgradeN5471I

Página 21

28Infiniium 90000 X-Series Oscilloscopes Performance characteristics VerticalInput channels FourAnalog bandwidth (–3 dB)*, 2 channel 2 chann

Página 22 - Protocol analysis

29Infiniium 90000 X-Series Oscilloscopes Performance characteristics HorizontalMain timebase range 2 ps/div to 20 s/div real-time Main timebase dela

Página 23

3The industry’s highest real-time scope measurement accuracy. When you’re designing with faster signals, shrinking eyes and tighter jitter budgets err

Página 24 - Mainframe:

30Infiniium 90000 X-Series Oscilloscopes Performance characteristics AcquisitionMaximum real-time sample rate 91304A 91604A 92004A

Página 25 - 2(b). Choose MSO options

31Infiniium 90000 X-Series Oscilloscopes Performance characteristics Hardware triggerSensitivity Internal low: 2.0 div p-p 0 to 22 GHz Internal high

Página 26 - Packages

32Hardware trigger (Continued) Video Trigger sequencesTriggers from negative sync composite video, field 1, field 2, or alternating fields for

Página 27 - Upgrade your oscilloscope

33Infiniium 90000 X-Series Oscilloscopes Performance characteristics Maximum measurement update rate> 50,000 measurement/sec (one measurement tur

Página 28 - Performance characteristics

34Infiniium 90000 X-Series Oscilloscopes Performance characteristics Waveform math Number of functions Hardware accelerated math Operati

Página 29

35Infiniium 90000 X-Series Oscilloscopes Performance characteristics Computer system and peripherals Operating system CPU PC system memory Driv

Página 30

36Agilent Technologies OscilloscopesMultiple form factors from 20 MHz to > 90 GHz | Industry leading specs | Powerful applications

Página 31

MATLAB® is a U.S. registered trademark of The Math Works, Inc. PCI Express®, PCIe and PCI-SIG are registered trademarks of PCI-SIGmyAgilentmyAgilentww

Página 32

4Engineered for 33 GHz true analog bandwidth that now combines deep logic analysis with the industry’s highest performance oscilloscope:33 GHz true a

Página 33

5Removable solid state drive option is available. It offers improved data security and speed.10 MHz reference clock can be input to or output from the

Página 34

6True-analog bandwidth- 33 GHz The engineering of a high-performance real-time oscilloscope front end requires designing pre-amplifiers, triggering ca

Página 35

7Better calibration improves spectral purityAgilent oscilloscopes are constantly improving their measurement accuracy. The latest innovation is a new,

Página 36

8Engineered for 33 GHz true analog bandwidth that delivers:A mixed signal oscilloscope integrates traditional analog channels with 16 digital channels

Página 37 - PCI Express

9Engineered for 33 GHz true analog bandwidth that delivers:Industry’s only bandwidth upgradable probes Purchase the probing performance you need toda