Agilent Technologies HP8648A Manual do Utilizador Página 296

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 320
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 295
RF Analyzer Specifications
295
AM Measurement
Frequency Range: 10 MHz to 1 GHz (usable to 400 kHz)
Depth: 0 to 95%
Accuracy: ±5% of reading ±1.5% AM (50 Hz to 10 kHz rates, modulation
80%)
THD+Noise: <2% rms for modulation 80% AM (1 kHz rate in a 0.3 to 3
kHz BW)
Input Level for Specified Accuracy (levels in PEP):
Standard:
18 to +50 dBm at RF IN/OUT (0.016 mW to 100 W)
50 to +14 dBm at ANT IN
Option 007:
32 to 36 dBm at RF IN/OUT (0.63 µW to 4.0 W)
Residual AM: <0.2% in a 0.3 to 3 kHz BW
Resolution: 0.1%
SSB Measurement
Frequency Range: 400 kHz to 1 GHz
Bandwidth (3 dB): 20 Hz to 70 kHz
Distortion and Noise: <3% at 1 kHz rate in a 0.3 to 3 kHz BW
Vista de página 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 319 320

Comentários a estes Manuais

Sem comentários