Agilent Technologies A.18.00 Manual do Utilizador Página 458

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 581
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 457
458
S:\agilent\8920\8920b\PRGGUIDE\BOOK\CHAPTERS\callproc.fb
Chapter 8, Programming the Call Processing Subsystem
Programming the CALL CONTROL Screen
Register
This field is used to initiate a registration of the mobile station connected to the
Test Set.
The Test Set must be in the active state (that is, the
Active annunciator lit) before
attempting to register a mobile station.
The :REGister command is used to control this field.
There is no query form of the :REGister command.
Syntax
:REGister
Example
OUTPUT 714;"CALLP:REG"
[] Register
When lit, the Register annunciator indicates that the mobile station connected
to the Test Set is being commanded to register with the Test Set
The
Register annunciator is not programmable.
The state of the
Register annunciator is reflected in the Call Processing Status
Register Group Condition Register bit 1. See “Status Reporting” in the
Application Guide for further information.
Vista de página 457