Chapter 8, Programming the Call Processing Subsystem
Programming the CALL CONTROL Screen
Page
This field is used to initiate a page to the mobile station connected to the Test Set.
The Test Set must be in the active state (that is,
Active annunciator lit) and the
MS Id information must be correct before attempting to page a mobile station.
The :PAGE command is used to control this field.
There is no query form of the :PAGE command.
Syntax
:PAGE
Example
OUTPUT 714;"CALLP:PAGE"
[] Page
When lit, the Page annunciator indicates that the mobile station connected to the
Test Set is currently being paged on the forward control channel.
The
Page annunciator is not programmable.
The state of the
Page annunciator is reflected in the Call Processing Status
Register Group Condition Register bit 3.
See “Call Processing Status Register
Group” on page 271
for further information.