6-68 Chapter6
Front-Panel Key Reference
Preset
User Preset Loads the analyzer configuration that existed when Save User Preset
was pressed. If Save User Preset has never been pressed, the factory
preset state is loaded. If the user preset state has been saved but the
load fails for any reason, the error message: Unable to load user
state is displayed in the status line and the state is reset to whatever
it was before the
Preset key was pressed. This can sometimes happen if
firmware has been upgraded or applications (un)installed after the user
preset state was saved.
Save User Preset can be accessed by pressing
System, Power On/Preset.
Trigger free run
Trig Delay Off 1 µsec
Trig Offset Off 0 sec
VBW/RBW ratio 1.000 X
Video averaging off
Video bandwidth 3 MHz (auto-coupled)
Table 6-1 Factory Preset Conditions